510(k) · Cleared
ClearedSensititre Aim (TM)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Trek Diagnostic Systems, Ltd. · LIE Reagent/Device, Inoculum Calibration
Cleared on Apr 27, 2011 after an 83-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Apr 27, 2011
- Review
- 83 days
- Class
- Class II
- Product code
- LIE
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LIE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LIE device
- #1 K221493 MicroScan Prompt Inoculation System-Dscore 5.1 · 1 generation · no Class I recall
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LIE devicesLIE Reagent/Device, Inoculum Calibration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · LIE
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · LIE
Too few LIE 510(k)s in any year since 2007 to give a median.
Recalls per year · LIE
No recall names LIE since 2007.
Adverse event reports per year · LIE
No MAUDE report names LIE since 2007.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 2 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Sensititre® AIMTM is intended for use with the Sensititre® MIC or BP Susceptibility Test System. The Sensititre® AIMTM is an instrument used to inoculate Sensititre® MIC or BP Susceptibility plates.
The Sensititre MIC or Breakpoint Susceptibility System is an in vitro diagnostic product for clinical susceptibility testing of non fastidious gram negative organisms.
NOTE: Please refer to the Sensititre® 18-24 hour MIC or Breakpoint Susceptibility System package insert or operator's manual for additional instructions, limitations and references.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K110331 · printed Nov 3, 2026
Cite this page
510(k) Report. “K110331: Sensititre Aim (TM).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K110331
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026