510(k) Report

510(k) · Cleared

Cleared

Ekf- Diagnostic Hemo_Control Hemoglobin Measurement System; Ekf-Diagnostic Hemoglobin Microcuvettes (Modified Curvette W

K110393510(k) SpecialCleared Mar 4, 201121-day reviewClass II21 CFR 864.5620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ekf-Diagnostic GmbH · GKR System, Hemoglobin, Automated

Cleared on Mar 4, 2011 as substantially equivalent to K031898 (Ekf Diagnostic GmbH, 2003) and 1 other predicate after a 21-day review. Its family tree reaches back 1 generation to 2003.

Decided
Mar 4, 2011
Review
21 days
Class
Class II
Product code
GKR
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K031898 (2003). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2008: 1 other ancestorK031898 · Ekf Diagnostic Hemo Control Hemoglobin Measurement System · Ekf Diagnostic GmbH · 20032000200220042006200820102012
Other ancestors, by generation 1 generation back: 1 other ancestor K031898 · Ekf Diagnostic Hemo Control Hemoglobin Measurement System · Ekf Diagnostic GmbH · 20030
  1. Root · 1 generation backK031898 Ekf Diagnostic Hemo Control Hemoglobin Measurement SystemEkf Diagnostic GmbH · 2003
  2. This deviceK110393 Ekf- Diagnostic Hemo_Control Hemoglobin Measurement System…Ekf-Diagnostic GmbH · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K031898Ekf Diagnostic Hemo Control Hemoglobin Measurement SystemEkf Diagnostic GmbH2003—
0 (this device)K110393Ekf- Diagnostic Hemo_Control Hemoglobin Measurement System; Ekf-Diagnostic…Ekf-Diagnostic GmbH2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200810
FIG. 1 — Lineage of K110393, 2003–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKR device

  1. #1 K201217 HemoCue Hb 301 Systemscore 0.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031898Ekf Diagnostic Hemo Control Hemoglobin Measurement System
Summary page 1
…Class 11 (3) Predicate Device(s): Hemno_-Control Hemoglobin Measurement System (K031 898) Modification To Stanbio Laboratory H…
Ekf Diagnostic GmbH2003—
*K081719Stanbio Laboratory Hemopoint H2 Hemoglobin Measurement System
Summary page 1
…odification To Stanbio Laboratory Hemopoint H2 Hemoglobin Measurement System (K081719) Reason for Submission: Device Modification (4) Description of Device: The Hemo-Contr…
Stanbio Laboratory20081

Also cleared against K031898: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • 1 other device also cites its predicate K031898.

How does its category compare?

All GKR devices

GKR System, Hemoglobin, Automated: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · GKR

2in 2020

2008: 12009: 12011: 12013: 22017: 12018: 22019: 12020: 2
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKR

Too few GKR 510(k)s in any year since 2007 to give a median.

Recalls per year · GKR

1in 2013

2010: 12011: 12013: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GKR

1in 2024

2008: 22009: 162010: 92011: 122012: 252013: 432014: 312015: 192016: 92019: 92020: 12021: 12022: 12024: 1
2007high 43 (2013) · low 0 (2007)2025

MAUDE reports naming product code GKR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—02
20091—016
20100—19
20111—112
20120—025
20132—143
20140—031
20150—019
20160—09
20171—00
20182—00
20191—09
20202—01
20210—01
20220—01
20230—00
20240—01
20250—00
20260—0—

What is it indicated for?

The Hemo-Control Hemoglobin Measurement System is indicated for the quantitative determination of hemoglobin in arterial, venous, or capillary blood. The microcuvettes part number 3000-3012-0765 are indicated for use in the Hemo-Control Hemoglobin Measurement System and compatible measurement systems. The microcuvettes are intended to be used only once and must be disposed of after use as potentially infectious waste. Estimation of hematocrit as a…

Read the full statement (106 words)

The Hemo-Control Hemoglobin Measurement System is indicated for the quantitative determination of hemoglobin in arterial, venous, or capillary blood.

The microcuvettes part number 3000-3012-0765 are indicated for use in the Hemo-Control Hemoglobin Measurement System and compatible measurement systems. The microcuvettes are intended to be used only once and must be disposed of after use as potentially infectious waste.

Estimation of hematocrit as a function of Hemoglobin is performed for normal hemoglobin ranges only (120 to 180 g/liter or 12.0 to 18.0 g/deciliter). The estimated hematocrit is not indicative of disease states such as anemia and abnormal values will not be reported.

For InVitro Diagnostic Use Only

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110393: Ekf- Diagnostic Hemo_Control Hemoglobin Measurement System; Ekf-Diagnostic Hemoglobin Microcuvettes (Modified Curvette W.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110393

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026