510(k) Report

510(k) · Cleared

Cleared

F10

K110630510(k) TraditionalCleared Jun 24, 2011113-day reviewClass II21 CFR 884.2660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mediana Co., Ltd. · KNG Monitor, Ultrasonic, Fetal

Cleared on Jun 24, 2011 as substantially equivalent to K040480 (Edan Instruments, Inc., 2004) and 1 other predicate after a 113-day review. Its family tree reaches back 4 generations to 1994.

Decided
Jun 24, 2011
Review
113 days
Class
Class II
Product code
KNG
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K930200 (1994). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK930200 Multi Dopplex II / Fetal Dopplex IIHuntleigh Healthcare, Inc. · 1994
  2. 3 generations backK991441 Cadence Doppler Ultrasound SystemMedasonics, Inc. · 1999
  3. 2 generations backK040480 Sonotrax Ultrasonic Pocket DopplerEdan Instruments, Inc. · 2004
  4. 1 generation backK052190 Fetal Monitor, Models BT-300 and BT-200Bistos Co., Ltd. · 2005
  5. This deviceK110630 F10Mediana Co., Ltd. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K930200Multi Dopplex II / Fetal Dopplex IIHuntleigh Healthcare, Inc.1994—
−3K991441Cadence Doppler Ultrasound SystemMedasonics, Inc.1999—
−2K040480Sonotrax Ultrasonic Pocket DopplerEdan Instruments, Inc.2004—
−1K052190Fetal Monitor, Models BT-300 and BT-200Bistos Co., Ltd.2005—
0 (this device)K110630F10Mediana Co., Ltd.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
200010
200110
200310
FIG. 1 — Lineage of K110630, 1994–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNG device

  1. #1 K252669 Fetal Doppler U8-25, U9-25score 13.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040480Sonotrax Ultrasonic Pocket Doppler
Summary page 1
…e predicate devices for Fetal Doppler, Model F1l0 are: * Edan Instruments, Inc. Ultrasonic Pocket Doppler, Sonotrax cleared by FDA through 510(k) No. K040480 (Decision Date -May.25. 2004), and * Bistos Co., Ltd. Ultrasonic Pocket Doppler, BT-200…
Edan Instruments, Inc.2004—
*K052190Fetal Monitor, Models BT-300 and BT-200Bistos Co., Ltd.2005—

Also cleared against K040480: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 5 companies; a new generation was cleared every 5.5 years on median.
  • None of the 9 ancestors has a recall.
  • 4 other devices also cite its predicate K040480.

How does its category compare?

All KNG devices

KNG Monitor, Ultrasonic, Fetal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · KNG

1in 2025

2008: 12009: 32010: 22011: 52014: 12015: 12016: 12018: 32019: 32021: 12022: 22024: 22025: 12026 (partial year): 1
2007high 5 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNG

202in 2019

2009: 181 days median2011: 57 days median2018: 154 days median2019: 202 days median
2007high 202 (2019) · low 57 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNG

No recall names KNG since 2007.

Adverse event reports per year · KNG

1in 2025

2008: 22013: 12014: 12017: 32018: 82019: 12020: 22021: 12023: 22024: 32025: 1
2007high 8 (2018) · low 0 (2007)2025

MAUDE reports naming product code KNG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—02
2009318100
20102—00
201155700
20120—00
20130—01
20141—01
20151—00
20161—00
20170—03
2018315408
2019320201
20200—02
20211—01
20222—00
20230—02
20242—03
20251—01
20261—0—

What is it indicated for?

The F10 Fetal Doppler measures heart rate, which is displayed on a LCD display and provides fetal heart sounds. The fetal heart rate is measured using Doppler ultrasound.

Intended use : Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110630: F10.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110630

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026