# K110632: Lucent or Lucent Magnum

- Pathway: 510(k) (Traditional)
- Applicant: Spinal Elements, Inc.
- Decided: May 23, 2012 after 446 days
- Product code: MAX (Intervertebral Fusion Device With Bone Graft, Lumbar)
- Device class: 2
- Regulation: 21 CFR 888.3080
- Recalls of this device: 1 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 2 generations back to P980048 (2001). 6 ancestors in all.
694 later devices descend from it; 12 cite it directly.
1 of 701 devices in its family (counting itself) has a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K071724: Lucent, Spinal Elements, Inc. (2007) Summary page 2.
- K073348: Lucent Magnum, Spinal Elements, Inc. (2007) Summary page 2.
- K112036: Calix PC Spinal Implant System, X-Spine Systems, Inc. (2011). Cleared while this submission was under review

## Most influential descendants
- K122967: Lucent (2013), 615 descendants of its own
- K140319: Coroent TI-C System (2014), 590 descendants of its own
- K141665: NuVasive CoRoent System (2015), 588 descendants of its own
- K151472: NuVasive CoRoent Lumbar System (2015), 479 descendants of its own
- K150994: NuVasive CoRoent Thoracolumbar Implants (2015), 402 descendants of its own

## Recalls of this device
- Dec 18, 2014 · Class II · Z-0907-2015: Spinal Elements is recalling the Ti-Bond related brochures that includes LT-10000 and MP-14000 (all revisions) the content regarding the Ti-Bond coating within the literature is unsubstantiated in con

## Indications for use
Lucent®K and Lucent Magnum® are intervertebral body fusion devices intended for spinal fusion procedures at one or two contiguous levels (TI-L-5) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved levels. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). This device is intended to be used with supplemental spinal fixation systems that have been cleared for use in the lumbosacral spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems). This device is intended to be used with autogenous bone graft. Patients must have undergone a regimen of at least six (6) months non-operative treatment prior to being treated with this device.