Spinal Solutions, LLC · MNH Orthosis, Spondylolisthesis Spinal Fixation

Cleared on Dec 15, 2011 as substantially equivalent to K033826 (Orthopedic Alliance, LLC, 2004) and 1 other predicate after a 286-day review. Its family tree reaches back 4 generations to 1999. It has been recalled 8 times.

Decided
Dec 15, 2011
Review
286 days
Class
Class II
Product code
MNH
Recalls
8
Predicates
2

Its longest line of descent runs back 4 generations to K990745 (1999). 15 ancestors in all, the oldest K901587 (1990). No later device cites it as a predicate yet.

Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 9 other ancestors K092420 · KRD1 Pedicle Screw System · Spinefrontier, Inc. · 2009 · recalledK052123 · Synthes Pangea System · Synthes (Usa) · 2005K992739 · Click'x · Synthes Spine · 2000 · recalledK990745 · Modification to Synthes Universal Spinal System · Synthes Spine · 19990
  1. Root · 4 generations backK990745 Modification to Synthes Universal Spinal SystemSynthes Spine · 1999
  2. 3 generations backK992739 Click'xSynthes Spine · 2000 · Recalled
  3. 2 generations backK052123 Synthes Pangea SystemSynthes (Usa) · 2005
  4. 1 generation backK092420 KRD1 Pedicle Screw SystemSpinefrontier, Inc. · 2009 · Recalled
  5. This deviceK110633 Lancer Pedicle Screw SystemSpinal Solutions, LLC · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K990745Modification to Synthes Universal Spinal SystemSynthes Spine1999—
−3K992739Click'xSynthes Spine20001
−2K052123Synthes Pangea SystemSynthes (Usa)2005—
−1K092420KRD1 Pedicle Screw SystemSpinefrontier, Inc.20092
0 (this device)K110633Lancer Pedicle Screw SystemSpinal Solutions, LLC2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199020
199250
199320
199710
200410
FIG. 1 — Lineage of K110633, 1999–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033826Orthopedic Alliance Spine System
Summary page 1
…ate or legally marketed devices which are substantially equivalent: The Lancer Pedicle Screw System isa modification of the Orthopedic Alliance Spine System (K033826). Other predicate devices include: KRD-1"'- - K092420 (SpineFrontier) 4. Description of the device: The Lancer Ped…
Orthopedic Alliance, LLC20041
*K092420KRD1 Pedicle Screw System
Summary page 1
…alent: The Lancer Pedicle Screw System isa modification of the Orthopedic Alliance Spine System (K033826). Other predicate devices include: KRD-1"'- - K092420 (SpineFrontier) 4. Description of the device: The Lancer Pedlicle Screw System is comprised of polyaxial pedicle screws,…
Spinefrontier, Inc.20092
†K000236Synergy VLS Cap Nut Models 2206, 6102Interpore Cross Intl.2000—
†K950697Depuy Motech Moss Miami Spinal System - Pedicle FixationDepuy Motech1995—

Also cleared against K033826: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 20, 2013Class IIZ-1415-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1413-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1410-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1412-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1416-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1411-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1409-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.
Feb 20, 2013Class IIZ-1414-2013Labeling designThe recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Spinal Solutions because the directions for use and surgical techniques were not being provided to every physician and for every surgery.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 4.2 years on median.
  • 3 of the 15 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K033826.

How does its category compare?

All MNH devices

MNH Orthosis, Spondylolisthesis Spinal Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MNH

8in 2016

2007: 52008: 132009: 132010: 102011: 172012: 72013: 102014: 122015: 102016: 8
2007high 17 (2011) · low 0 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNH

93in 2016

2007: 123 days median2008: 65 days median2009: 151 days median2010: 106 days median2011: 171 days median2012: 93 days median2013: 124 days median2014: 140 days median2015: 99 days median2016: 93 days median
2007high 171 (2011) · low 65 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MNH

1in 2016

2009: 72012: 12013: 12016: 1
2007high 7 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MNH

89in 2025

2007: 182008: 302009: 452010: 592011: 1072012: 4332013: 4642014: 2862015: 1522016: 2162017: 1742018: 1292019: 4032020: 4322021: 5312022: 2652023: 1212024: 3022025: 89
2007high 531 (2021) · low 18 (2007)2025

MAUDE reports naming product code MNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075123018
20081365030
200913151745
201010106059
2011171710107
20127931433
2013101241464
2014121400286
201510990152
20168931216
20170—0174
20180—0129
20190—0403
20200—0432
20210—0531
20220—0265
20230—0121
20240—0302
20250—089
20260—0—

What is it indicated for?

The Lancer Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of thoracic, lumbar, and sacral spine: fracture, dislocation, failed previous fusion (pseudoarthrosis), degenerative spondylolisthesis with objective evidence of neurological impairment, spinal deformations such as…

Read the full statement (132 words)

The Lancer Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of thoracic, lumbar, and sacral spine: fracture, dislocation, failed previous fusion (pseudoarthrosis), degenerative spondylolisthesis with objective evidence of neurological impairment, spinal deformations such as scoliosis or kylphosis and loss of stability due to tumors.

When used as a pedicle screw system, the Lancer Pedlicle Screw System is intended for the treatment of severe spondylolisthesis (Grade 3 and 4) of the L_5-S1 vertebrae in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110633: Lancer Pedicle Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K110633

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026