510(k) Report

510(k) · Cleared

Cleared

Del Mar Monoaxial Pedicle Screw System

K110679510(k) SpecialCleared Aug 2, 2011145-day reviewClass II21 CFR 888.3070

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Phygen, LLC · NKB Thoracolumbosacral Pedicle Screw System

Cleared on Aug 2, 2011 as substantially equivalent to K091219 (Allez Spine, LLC, 2009) and 1 other predicate after a 145-day review. Its family tree reaches back 3 generations to 1999.

Decided
Aug 2, 2011
Review
145 days
Class
Class II
Product code
NKB
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K981676 (1999). 4 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK981676 CD Horizon Spinal SystemSofamor Danek USA,Inc. · 1999
  2. 2 generations backK050060 Laguna Pedicle Screw SystemAllez Spine, LLC · 2005 · Recalled
  3. 1 generation backK051275 Laguna Monoaxial Pedicle Screw SystemAllez Spine, LLC · 2005 · Recalled
  4. This deviceK110679 Del Mar Monoaxial Pedicle Screw SystemPhygen, LLC · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K981676CD Horizon Spinal SystemSofamor Danek USA,Inc.1999—
−2K050060Laguna Pedicle Screw SystemAllez Spine, LLC200527
−1K051275Laguna Monoaxial Pedicle Screw SystemAllez Spine, LLC200521
0 (this device)K110679Del Mar Monoaxial Pedicle Screw SystemPhygen, LLC2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200910
FIG. 1 — Lineage of K110679, 1999–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NKB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NKB device

  1. #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091219Del Mar Monoaxial Pedicle Screw System
Summary page 1
…r ASTM F1 058. Equivalence: The modified Del Mar® Pedicle Screw System is substantially equivalent to the Del Mar@ Pedicle Screw System (K091 219 S/E 7/9/2009 and unmodified K051275 S/E 12/9/2005, which is manufactured and marketed by Phygen,…
Allez Spine, LLC2009—
*K051275Laguna Monoaxial Pedicle Screw System
Summary page 1
…Pedicle Screw System is substantially equivalent to the Del Mar@ Pedicle Screw System (K091 219 S/E 7/9/2009 and unmodified K051275 S/E 12/9/2005, which is manufactured and marketed by Phygen, LLC. 51 0(k) Summary for Del Mar® Ped…
Allez Spine, LLC200521

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 5.6 years on median.
  • 2 of the 4 ancestors have a recall of any class.

How does its category compare?

All NKB devices

NKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · NKB

24in 2025

2007: 382008: 362009: 442010: 372011: 482012: 602013: 352014: 462015: 552016: 502017: 632018: 562019: 392020: 482021: 322022: 342023: 442024: 392025: 242026 (partial year): 30
2007high 63 (2017) · low 24 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NKB

61in 2025

2007: 87 days median2008: 59 days median2009: 71 days median2010: 111 days median2011: 84 days median2012: 79 days median2013: 73 days median2014: 90 days median2015: 90 days median2016: 84 days median2017: 69 days median2018: 61 days median2019: 84 days median2020: 68 days median2021: 61 days median2022: 88 days median2023: 72 days median2024: 57 days median2025: 61 days median2026 (partial year): 91 days median
2007high 111 (2010) · low 57 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NKB

1in 2025

2007: 42008: 52009: 332010: 42011: 32012: 132014: 3, 1 Class I2015: 32016: 12017: 12018: 32019: 12020: 12022: 52023: 22024: 32025: 12026 (partial year): 3
2007high 33 (2009) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · NKB

1,171in 2025

2007: 342008: 822009: 1712010: 4622011: 5772012: 1,7472013: 1,9622014: 1,6712015: 1,4462016: 1,5852017: 1,6182018: 1,6842019: 1,9152020: 2,0762021: 1,7452022: 1,3392023: 9192024: 1,6142025: 1,171
2007high 2,076 (2020) · low 34 (2007)2025

MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073887434
20083659582
2009447133171
2010371114462
201148843577
20126079131,747
2013357301,962
201446903 (1)1,671
2015559031,446
2016508411,585
2017636911,618
2018566131,684
2019398411,915
2020486812,076
2021326101,745
2022348851,339
202344722919
2024395731,614
2025246111,171
202630913—

What is it indicated for?

The DEL MAR® Monoaxial Pedicle Screw System is intended to be used in skeletally mature patients as an adjunct to fusion using autograft or allograft in posterior, non-cervical fixation for the following conditions:

Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110679: Del Mar Monoaxial Pedicle Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K110679

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026