510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Randox Liquid Urine Control Levels 2 and 3

K110904510(k) TraditionalCleared Sep 30, 2011183-day reviewClass I21 CFR 862.1660Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Randox Laboratories, Ltd. · JJY Multi-Analyte Controls, All Kinds (Assayed)

Cleared on Sep 30, 2011 after a 183-day review. The FDA summary names no predicate by number. It has been recalled 2 times.

Decided
Sep 30, 2011
Review
183 days
Class
Class I
Product code
JJY
Recalls
2
Predicates
0

The FDA summary names no predicate by number.

FIG. 1 — Lineage of K110904Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 21, 2023Class IIZ-2446-2023Under Investigation by firm(1) There is vial to vial variation resulting in some vials recovering positive for hCG, which should be negative and (2) high and outside range for cortisol. (3) There has been a transcription error for Creatinine in the Instructions For…
Apr 27, 2017Class IIIZ-2167-2017Error in labelingAccording to Randox Laboratories an investigation indicates a labelling error for 2 of the test methods listed for quantification of Total Protein (urine). The values for the mean of all instruments are incorrect by a factor of 10.…

No ancestor or descendant has a Class I recall.

How does its category compare?

All JJY devices

JJY Multi-Analyte Controls, All Kinds (Assayed): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JJY

3in 2017

2007: 112008: 72009: 82010: 102011: 142012: 132013: 162014: 102015: 42016: 12017: 3
2007high 16 (2013) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJY

78in 2017

2007: 49 days median2008: 54 days median2009: 80 days median2010: 109 days median2011: 120 days median2012: 40 days median2013: 82 days median2014: 49 days median2015: 153 days median2017: 78 days median
2007high 153 (2015) · low 40 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJY

2in 2025

2007: 52009: 22010: 62011: 12012: 32013: 22014: 22015: 12016: 32017: 42018: 32019: 42020: 62022: 32023: 32025: 22026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJY

13in 2025

2007: 22008: 12009: 32010: 32011: 62012: 202013: 52014: 42015: 42016: 132017: 122018: 72019: 12020: 72021: 12023: 42024: 12025: 13
2007high 20 (2012) · low 0 (2022)2025

MAUDE reports naming product code JJY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007114952
200875401
200988023
20101010963
20111412016
20121340320
2013168225
2014104924
2015415314
20161—313
2017378412
20180—37
20190—41
20200—67
20210—01
20220—30
20230—34
20240—01
20250—213
20260—1—

What is it indicated for?

The Randox Liquid Urine Controls Level 2 and Level 3 are liquid controls containing Amylase, Calcium, Chloride, Cortisol, Creatinine, Glucose, hCG pregnancy, Magnesium, Microalbumnin, Osmolality, pH, Inorganic Phosphate, Potassium, Total Protein, Sodium, Specific Gravity, Urea and Uric Acid. They have been developed for in vitro diagnostic use in the quality control of Amylase, 'Calciurm, Chloride, Cortisol, Creatininej Glucose, hCG pregnaity; Magniesium, Microalbumnin, Osmolality, pH, Inorganic Phosphate, Potassium, Total Protein, Sodium, Specific Gravity, Urea and Uric Acid assays on various clinical chemistry systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110904: Randox Liquid Urine Control Levels 2 and 3.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K110904

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026