Cubescan / Biocon-700

K111021510(k) TraditionalCleared Apr 27, 201115-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mcube Technology Co., Ltd. · ITX Transducer, Ultrasonic, Diagnostic

Cleared on Apr 27, 2011 as substantially equivalent to K071217 (Verathon Incorporated, 2007) and 1 other predicate after a 15-day review. Its family tree reaches back 5 generations to 1992. 13 later devices descend from it.

Decided
Apr 27, 2011
Review
15 days
Class
Class II
Product code
ITX
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K915436 (1992). 8 ancestors in all. 13 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestor2017: 1 descendant cleared2013: 1 descendant cleared2023: 2 descendants cleared2019: 1 descendant cleared2018: 1 descendant cleared2016: 1 descendant cleared2020: 3 descendants cleared2021: 1 descendant cleared2026: 1 descendant cleared2025: 1 descendant clearedK915436 · Bladderscan Bvi 2500 · Diagnostic Ultrasound Corp. · 1992K955840 · Bladdermanager Pci 5000 / Bladderscan Bvi 5000 · Diagnostic Ultrasound Corp. · 1996K022153 · Bladderscan Bvi 6100 · Diagnostic Ultrasound Corp. · 2002 · recalledK071217 · Bladderscan Bvi 9400 Ultrasound · Verathon Incorporated · 2007 · recalledK091518 · Cubescan Biocon-500 Diagnostic Ultrasound System · Mcube Technology Co., Ltd. · 20091990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 1 other ancestor4 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 6 descendants3 generations forward: 3 descendants4 generations forward: 2 descendants K091518 · Cubescan Biocon-500 Diagnostic Ultrasound System · Mcube Technology Co., Ltd. · 2009K071217 · Bladderscan Bvi 9400 Ultrasound · Verathon Incorporated · 2007 · recalledK022153 · Bladderscan Bvi 6100 · Diagnostic Ultrasound Corp. · 2002 · recalledK955840 · Bladdermanager Pci 5000 / Bladderscan Bvi 5000 · Diagnostic Ultrasound Corp. · 1996K915436 · Bladderscan Bvi 2500 · Diagnostic Ultrasound Corp. · 1992−50
  1. Root · 5 generations backK915436 Bladderscan Bvi 2500Diagnostic Ultrasound Corp. · 1992
  2. 4 generations backK955840 Bladdermanager Pci 5000 / Bladderscan Bvi 5000Diagnostic Ultrasound Corp. · 1996
  3. 3 generations backK022153 Bladderscan Bvi 6100Diagnostic Ultrasound Corp. · 2002 · Recalled
  4. 2 generations backK071217 Bladderscan Bvi 9400 UltrasoundVerathon Incorporated · 2007 · Recalled
  5. 1 generation backK091518 Cubescan Biocon-500 Diagnostic Ultrasound SystemMcube Technology Co., Ltd. · 2009
  6. This deviceK111021 Cubescan / Biocon-700Mcube Technology Co., Ltd. · 2011
  7. Descendant · cites it directly · 7 of its ownK131227 Padscan HD Series Bladder ScannerCarenoso Technology Co., Ltd. · 2013
  8. Descendant · cites it directly · 4 of its ownK171591 CUBEScan™ BioCon-900 (Bladder Volume Measurement System)Mcube Technology Co., Ltd. · 2017
  9. Descendant · 2 generations on · 3 of its ownK190769 Bladder Scanner (Models: M2, M2-W, M1, M1-W)Suzhou Lischka Medtech Co., Ltd. · 2019
  10. Descendant · 3 generations on · 2 of its ownK201316 Bladder Scanner (Model: M3, M3-HD, M4, M4-HD)Suzhou Peaksonic Medical Technology Co., Ltd. · 2021
  11. Descendant · 2 generations on · 2 of its ownK200548 CUBEScan BioCon-1100Mcube Technology Co., Ltd. · 2020

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2013: 12016: 12017: 12018: 12019: 12020: 32021: 12023: 22025: 12026: 1
2013high 3 (2020) · low 0 (2014)2026

Most influential descendants

Showing 5 of 13 · See all
  • K131227Padscan HD Series Bladder ScannerCarenoso Technology Co., Ltd. · 2013 · cites it directly7descendants
  • K171591CUBEScan™ BioCon-900 (Bladder Volume Measurement System)Mcube Technology Co., Ltd. · 2017 · cites it directly4descendants
  • K190769Bladder Scanner (Models: M2, M2-W, M1, M1-W)Suzhou Lischka Medtech Co., Ltd. · 2019 · 2 generations on3descendants
  • K201316Bladder Scanner (Model: M3, M3-HD, M4, M4-HD)Suzhou Peaksonic Medical Technology Co., Ltd. · 2021 · 3 generations on2descendants
  • K200548CUBEScan BioCon-1100Mcube Technology Co., Ltd. · 2020 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K915436Bladderscan Bvi 2500Diagnostic Ultrasound Corp.1992—
−4K955840Bladdermanager Pci 5000 / Bladderscan Bvi 5000Diagnostic Ultrasound Corp.1996—
−3K022153Bladderscan Bvi 6100Diagnostic Ultrasound Corp.20021
−2K071217Bladderscan Bvi 9400 UltrasoundVerathon Incorporated20071
−1K091518Cubescan Biocon-500 Diagnostic Ultrasound SystemMcube Technology Co., Ltd.2009—
0 (this device)K111021Cubescan / Biocon-700Mcube Technology Co., Ltd.2011—
+1K131227Padscan HD Series Bladder ScannerCarenoso Technology Co., Ltd.2013—
+1K171591CUBEScan™ BioCon-900 (Bladder Volume Measurement System)Mcube Technology Co., Ltd.2017—
+2K190769Bladder Scanner (Models: M2, M2-W, M1, M1-W)Suzhou Lischka Medtech Co., Ltd.2019—
+3K201316Bladder Scanner (Model: M3, M3-HD, M4, M4-HD)Suzhou Peaksonic Medical Technology Co., Ltd.2021—
+2K200548CUBEScan BioCon-1100Mcube Technology Co., Ltd.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
199910
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201610
201710
201810
201910
202030
202110
202320
202510
202610
FIG. 1 — Lineage of K111021, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITX device

  1. #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071217Bladderscan Bvi 9400 Ultrasound
Summary page 1
…ative Device: Manufacturer :Verathon Inc. Device :BladderScan®g BVI 9400 510(k) Number :K071217(Decision Date - May 17, 2007) Manufacturer :Mcube Technology Device :C…
Verathon Incorporated20071
*K091518Cubescan Biocon-500 Diagnostic Ultrasound System
Summary page 1
…17, 2007) Manufacturer :Mcube Technology Device :CUBEscan / BioCon-$00 510(k) Number :K091518(Decision Date - June 18, 2009) 4. Classifications Names & Citations: 21CFR 892.1560, 1570, NYO, [TX, system, imaging,…
Mcube Technology Co., Ltd.2009—

Also cleared against K071217: 11 other devices →

What descends from it? (13)

See all 13

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131227Padscan HD Series Bladder ScannerCarenoso Technology Co., Ltd.20137
K171591CUBEScan™ BioCon-900 (Bladder Volume Measurement System)Mcube Technology Co., Ltd.20174

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 4.2 years on median.
  • 2 of the 8 ancestors have a recall of any class.
  • Of its descendants, K131227 (Carenoso Technology Co., Ltd., 2013) has gone furthest, with 7 descendants of its own.
  • 11 other devices also cite its predicate K071217.

How does its category compare?

All ITX devices

ITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · ITX

4in 2025

2007: 102008: 122009: 172010: 102011: 102012: 72013: 32014: 42015: 12016: 42017: 62018: 22019: 12020: 32021: 32022: 22023: 62024: 32025: 42026 (partial year): 6
2007high 17 (2009) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITX

126in 2025

2007: 26 days median2008: 73 days median2009: 28 days median2010: 42 days median2011: 16 days median2012: 25 days median2013: 105 days median2014: 41 days median2016: 151 days median2017: 110 days median2020: 120 days median2021: 139 days median2023: 213 days median2024: 81 days median2025: 126 days median2026 (partial year): 158 days median
2007high 213 (2023) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITX

2in 2025

2008: 42009: 42010: 42011: 12012: 12014: 12015: 52017: 12018: 152020: 32021: 10, 10 Class I2022: 62023: 12024: 12025: 2
2007high 15 (2018) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · ITX

571in 2025

2007: 162008: 392009: 232010: 302011: 342012: 292013: 382014: 432015: 1832016: 2692017: 4122018: 1302019: 1192020: 1162021: 1462022: 872023: 1382024: 9882025: 571
2007high 988 (2024) · low 16 (2007)2025

MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071026016
20081273439
20091728423
20101042430
20111016134
2012725129
20133105038
2014441143
20151—5183
201641510269
201761101412
20182—15130
20191—0119
202031203116
2021313910 (10)146
20222—687
202362131138
20243811988
202541262571
202661580—

What is it indicated for?

The BioCon-700 is a B-mode pulsed-echo ultrasound device. The BioCon-700 is intended as a portable battery-operated device. The BioCon-700 brojects ultrasonic energy through the abdomen of the patient obtaining images of the bladder in order to calculate the urine volume non-invasively. BioCon-700 is intended to be used by a qualified medical professional to non-invasively measure the urine volume in the bladder. Contraindications for the BioCon-700 are fetal use and use on pregnant patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K111021: Cubescan / Biocon-700.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111021

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026