ClearedPPX Reagent, PPX Calibrators, PPX QC Material
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medica Corp. · JXN Enzyme Immunoassay, Propoxyphene
Cleared on Dec 6, 2011 after a 204-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Dec 6, 2011
- Review
- 204 days
- Class
- Class II
- Product code
- JXN
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JXN devicesJXN Enzyme Immunoassay, Propoxyphene: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · JXN
1in 2015
2026 to Oct 25, outlined.
Median 510(k) review, days · JXN
Too few JXN 510(k)s in any year since 2007 to give a median.
Recalls per year · JXN
1in 2010
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JXN
1in 2024
MAUDE reports naming product code JXN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 1 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 1 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 1 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The EasyRA PPX reagent is intended for the qualitative and semi-quantitative measurement of Propoxyphene (PPX) in human urine, using MEDICA's EasyRA Chemistry Analyzer in clinical laboratories. The cut-off point of the assay is 300ng/ml, and provides only a preliminary analytical result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. Gas Chromatography/Mass Spectrometry (GC/MS) or Liquid…
Read the full statement (177 words)
The EasyRA PPX reagent is intended for the qualitative and semi-quantitative measurement of Propoxyphene (PPX) in human urine, using MEDICA's EasyRA Chemistry Analyzer in clinical laboratories. The cut-off point of the assay is 300ng/ml, and provides only a preliminary analytical result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. Gas Chromatography/Mass Spectrometry (GC/MS) or Liquid Chromatography/Mass Spectrometry (LC/MS) are the preferred confirmatory method. The semi-quantitative mode is intended to enable laboratories to determine the appropriate dilution of the specimen for confirmation by a reference method such as GC/MS or LC/MS and to allow laboratories to establish effective quality control procedures for the PFX assay.
Medica's Propoxyphene (PPX) Calibrators are intended for the calibration of the PPX Enzymatic Immunoassay to estimate propoxyphene in human urine, using Medica's PPX reagent on the EasyRA clinical chemistry analyzer.
Medica's Propoxylphene (PPX) CC Materials are intended for the validation of the PPX Enzymatic Immunoassay to estimate propoxyphene in human urine, using Medica's PPX reagent and PPX calibrator on the EasyRA clinical chemistry analyzer.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K111363 · printed Nov 6, 2026
Cite this page
510(k) Report. “K111363: PPX Reagent, PPX Calibrators, PPX QC Material.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111363
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026