510(k) Report

510(k) · Cleared

Cleared

Unimax Anti-Fog Solution

K111622510(k) TraditionalCleared Sep 9, 201191-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Unimax Medical Systems, Inc. · OCT Anti Fog Solution And Accessories, Endoscopy

Cleared on Sep 9, 2011 as substantially equivalent to K063587 (Xodus Medical, Inc., 2007) after a 91-day review. Its family tree reaches back 2 generations to 2002.

Decided
Sep 9, 2011
Review
91 days
Class
Class II
Product code
OCT
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K022826 (2002). No later device cites it as a predicate yet.

  1. Root · 2 generations backK022826 Clear-IT Anti-Fog, Model PS003Preservation Solutions, Inc. · 2002
  2. 1 generation backK063587 Xodus Medical Anti-Fog SolutionXodus Medical, Inc. · 2007
  3. This deviceK111622 Unimax Anti-Fog SolutionUnimax Medical Systems, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K022826Clear-IT Anti-Fog, Model PS003Preservation Solutions, Inc.2002—
−1K063587Xodus Medical Anti-Fog SolutionXodus Medical, Inc.2007—
0 (this device)K111622Unimax Anti-Fog SolutionUnimax Medical Systems, Inc.2011—
FIG. 1 — Lineage of K111622, 2002–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OCT device

  1. #1 K251068 KnoxFog Anti-fogging Devicescore 10.8 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K063587Xodus Medical Anti-Fog Solution
Summary page 4
…Endoscope And/ Or Accessories || 876.1500 Gastroenterology/Urology KOG Xodus Me:dical Anti-Fog Solution Xodus Medical, Inc. 510(k) Number or Clearance Information: K063587 .. Unimax Medical Systems Inc. Unimax Anti-Fog Solution 510(k) Notification 5.5 Intended Use and Indications fo…
Xodus Medical, Inc.2007—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 4.7 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All OCT devices

OCT Anti Fog Solution And Accessories, Endoscopy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · OCT

1in 2025

2007: 12008: 12010: 12011: 12012: 12016: 12017: 12019: 12020: 12022: 12024: 12025: 1
2007high 1 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OCT

Too few OCT 510(k)s in any year since 2007 to give a median.

Recalls per year · OCT

1in 2022

2022: 1
2007high 1 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OCT

13in 2025

2015: 132016: 272017: 182018: 202019: 202020: 142021: 162022: 102023: 132024: 92025: 13
2007high 27 (2016) · low 0 (2007)2025

MAUDE reports naming product code OCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
20090—00
20101—00
20111—00
20121—00
20130—00
20140—00
20150—013
20161—027
20171—018
20180—020
20191—020
20201—014
20210—016
20221—110
20230—013
20241—09
20251—013
20260—0—

What is it indicated for?

The Unimax Anti-Fog Solution is intended to be used to prevent “fogging” (caused by condensation) on the lenses of endoscopic/laparoscopic instruments which are likely to fog during use.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K111622: Unimax Anti-Fog Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111622

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026