510(k) Report

510(k) · Cleared

Cleared

Versapoint II Bipolar Electrosurgery Generator, Versapoint II 44MM Angled Loop Electrode, Versapoint II Footswitch, Vers

K111751510(k) TraditionalCleared Dec 2, 2011163-day reviewClass II21 CFR 884.4150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ETHICON, Inc. · HIN Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)

Cleared on Dec 2, 2011 as substantially equivalent to K962482 (Gynecare, Inc., 1996) and 1 other predicate after a 163-day review. Its family tree reaches back 1 generation to 1996. 1 later device descends from it.

Decided
Dec 2, 2011
Review
163 days
Class
Class II
Product code
HIN
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K962482 (1996). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2013: 1 descendant clearedK962482 · Scuba System · Gynecare, Inc. · 1996 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K962482 · Scuba System · Gynecare, Inc. · 1996 · recalled0
  1. Root · 1 generation backK962482 Scuba SystemGynecare, Inc. · 1996 · Recalled
  2. This deviceK111751 Versapoint II Bipolar Electrosurgery Generator, Versapoint II 44MM…ETHICON, Inc. · 2011
  3. Descendant · cites it directly · 0 of its ownK122983 Ksea Bipolar ElectrodeKARL STORZ Endoscopy-America, Inc. · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K122983Ksea Bipolar ElectrodeKARL STORZ Endoscopy-America, Inc. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K962482Scuba SystemGynecare, Inc.19961
0 (this device)K111751Versapoint II Bipolar Electrosurgery Generator, Versapoint II 44MM Angled Loop…ETHICON, Inc.2011—
+1K122983Ksea Bipolar ElectrodeKARL STORZ Endoscopy-America, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K111751, 1996–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HIN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K962482Scuba System
Summary page 1
…Regulatory Class: Class 11 Product Code: HIH Predicate 0 GYNECARE VERSAPOINT Bipolar Electrocautery System (K962482) Devices * VERSAPOINT VRS 2.5mm Angled Loop Electrode (K9944 18) Description of The GYNECARE VERSAPOINTTM 11 Bipola…
Gynecare, Inc.19961
*K994418Versapoint Electrosurgery System (Scuba)
Summary page 1
…Product Code: HIH Predicate 0 GYNECARE VERSAPOINT Bipolar Electrocautery System (K962482) Devices * VERSAPOINT VRS 2.5mm Angled Loop Electrode (K9944 18) Description of The GYNECARE VERSAPOINTTM 11 Bipolar Electrosurgery System the Device (VERSAPOINT 11 System) is the ne…
ETHICON, Inc.2000—

Also cleared against K962482: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K122983Ksea Bipolar ElectrodeKARL STORZ Endoscopy-America, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K122983 (KARL STORZ Endoscopy-America, Inc., 2013) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K962482.

How does its category compare?

All HIN devices

HIN Coagulator-Cutter, Endoscopic, Bipolar (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · HIN

1in 2014

2011: 22012: 22013: 22014: 1
2007high 2 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HIN

Too few HIN 510(k)s in any year since 2007 to give a median.

Recalls per year · HIN

No recall names HIN since 2007.

Adverse event reports per year · HIN

43in 2025

2009: 62010: 72011: 62012: 12013: 142014: 122015: 82016: 22017: 82018: 22019: 42020: 92021: 102022: 12023: 92024: 292025: 43
2007high 43 (2025) · low 0 (2007)2025

MAUDE reports naming product code HIN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—06
20100—07
20112—06
20122—01
20132—014
20141—012
20150—08
20160—02
20170—08
20180—02
20190—04
20200—09
20210—010
20220—01
20230—09
20240—029
20250—043
20260—0—

What is it indicated for?

The GYNECARE VERSAPOINTTM 11 Bipolar Electrosurgery System is intended for use in tissue cutting, removal and desiccation as requited or encountered in gynecologic hysteroscopic electrosurgical procedures for the treatment of intrauterine myomas, polyps, adhesions, and septa, and benign conditions requiting endometrial ablation. Procedures include:

* Excision of intrauterine myomas

* Excision of intrauterine polyps

* Lysis of intrauterine adhesions

* Incision of uterine septa

* Endometrial ablation

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K111751: Versapoint II Bipolar Electrosurgery Generator, Versapoint II 44MM Angled Loop Electrode, Versapoint II Footswitch, Vers.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111751

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026