510(k) Report

510(k) · Cleared

Cleared

Simmetry (TM) Sacroiliac Joint Fusion System

K111801510(k) TraditionalCleared Jul 21, 201124-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zyga Technology, Inc. · OUR Sacroiliac Joint Fixation

Cleared on Jul 21, 2011 as substantially equivalent to K110512 (Zyga Technology, Inc., 2011) after a 24-day review. Its family tree reaches back 4 generations to 1990. 1 of the 249 devices in its family, counting itself, has a Class I recall. 240 later devices descend from it.

Decided
Jul 21, 2011
Review
24 days
Class
Class II
Product code
OUR
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K903810 (1990). 8 ancestors in all. 240 later devices descend from it, 3 citing it directly. 1 of the 249 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2009: 1 other ancestor2002: 2 other ancestors2000: 1 other ancestor2013: 1 descendant cleared2011: 1 descendant cleared2012: 2 descendants cleared2018: 7 descendants cleared2016: 6 descendants cleared2024: 37 descendants cleared2021: 18 descendants cleared, 1 with a Class I recall12014: 2 descendants cleared2019: 10 descendants cleared2023: 40 descendants cleared2015: 4 descendants cleared2017: 4 descendants cleared2020: 10 descendants cleared2022: 24 descendants cleared2026: 38 descendants cleared2025: 36 descendants clearedK903810 · Ace Cannulated Self Tapping Cancellous Bone Screw · Ace Medical Co. · 1990K051296 · Sijf Cannulated Screw System · Depuy Spine, Inc. · 2005×2: 2 generations cleared close together, K102907 (2010), K110512 (2011) 1990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors4 generations back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 20 descendants3 generations forward: 90 descendants, 1 with a Class I recall14 generations forward: 47 descendants5 generations forward: 34 descendants6 generations forward: 19 descendants7 generations forward: 10 descendants8 generations forward: 7 descendants9 generations forward: 6 descendants10 generations forward: 4 descendants K110512 · Simmetry Sacroiliac Joint Fusion System · Zyga Technology, Inc. · 2011K102907 · Simmetry Sacroiliac Joint Fusion System · Zyga Technology, Inc. · 2010K051296 · Sijf Cannulated Screw System · Depuy Spine, Inc. · 2005K903810 · Ace Cannulated Self Tapping Cancellous Bone Screw · Ace Medical Co. · 19900+5+10
  1. Root · 4 generations backK903810 Ace Cannulated Self Tapping Cancellous Bone ScrewAce Medical Co. · 1990
  2. 3 generations backK051296 Sijf Cannulated Screw SystemDepuy Spine, Inc. · 2005
  3. 2 generations backK102907 Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc. · 2010
  4. 1 generation backK110512 Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc. · 2011
  5. This deviceK111801 Simmetry (TM) Sacroiliac Joint Fusion SystemZyga Technology, Inc. · 2011
  6. Descendant · cites it directly · 238 of its ownK112028 SI-Lok Sacroiliac Joint Fixation SystemGlobus Medical, Inc. · 2011
  7. Descendant · cites it directly · 92 of its ownK110472 SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek · 2012
  8. Descendant · cites it directly · 85 of its ownK130092 Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc. · 2013
  9. Descendant · 2 generations on · 84 of its ownK152681 iFuse Implant System (R)SI-BONE, Inc. · 2016
  10. Descendant · 3 generations on · 83 of its ownK160652 iFUSE Implant SystemSI-BONE, Inc. · 2016

Showing 5 of 240 descendants. See all descendants

Descendants cleared per year

2011: 12012: 22013: 12014: 22015: 42016: 62017: 42018: 72019: 102020: 102021: 182022: 242023: 402024: 372025: 362026: 38
2011high 40 (2023) · low 1 (2011)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 240 · See all
  • K112028SI-Lok Sacroiliac Joint Fixation SystemGlobus Medical, Inc. · 2011 · cites it directly238descendants
  • K110472SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek · 2012 · cites it directly92descendants
  • K130092Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc. · 2013 · cites it directly85descendants
  • K152681iFuse Implant System (R)SI-BONE, Inc. · 2016 · 2 generations on84descendants
  • K160652iFUSE Implant SystemSI-BONE, Inc. · 2016 · 3 generations on83descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K903810Ace Cannulated Self Tapping Cancellous Bone ScrewAce Medical Co.1990—
−3K051296Sijf Cannulated Screw SystemDepuy Spine, Inc.2005—
−2K102907Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc.2010—
−1K110512Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc.2011—
0 (this device)K111801Simmetry (TM) Sacroiliac Joint Fusion SystemZyga Technology, Inc.2011—
+1K112028SI-Lok Sacroiliac Joint Fixation SystemGlobus Medical, Inc.2011—
+1K110472SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek2012—
+1K130092Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc.2013—
+2K152681iFuse Implant System (R)SI-BONE, Inc.2016—
+3K160652iFUSE Implant SystemSI-BONE, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
200220
200910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201220
201310
201420
201540
201660
201740
201870
2019100
2020100
2021181
2022240
2023400
2024370
2025360
2026380
FIG. 1 — Lineage of K111801, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OUR device

  1. #1 K233508 iFuse Bedrock Granite® Implant Systemscore 30.7 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110512Simmetry Sacroiliac Joint Fusion System
Summary page 2
…and material Conclsioncomposition and mechanical performance when compared to the predicate device cleared under ________________ K110512. Paget 7-4 DEPARTM…
Zyga Technology, Inc.2011—

Also cleared against K110512: 1 other device →

What descends from it? (240)

See all 240

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112028SI-Lok Sacroiliac Joint Fixation SystemGlobus Medical, Inc.2011238
K110472SI-Fix Sacroiliac Joint Fusion SystemMedtronic Sofamor Danek201292
K130092Simmetry Sacroiliac Joint Fusion SystemZyga Technology, Inc.201385

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K211616ExcelsiusHubGlobus Medical, Inc. · 2021 · 3 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 5.3 years on median.
  • 2 of the 8 ancestors have a recall of any class.
  • Of its descendants, K112028 (Globus Medical, Inc., 2011) has gone furthest, with 238 descendants of its own.
  • 1 other device also cites its predicate K110512.

How does its category compare?

All OUR devices

OUR Sacroiliac Joint Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · OUR

14in 2025

2008: 12009: 12010: 12011: 32012: 22013: 42014: 32015: 82016: 62017: 42018: 72019: 72020: 72021: 92022: 142023: 202024: 152025: 142026 (partial year): 6
2007high 20 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OUR

97in 2025

2011: 27 days median2013: 103 days median2014: 91 days median2015: 111 days median2016: 168 days median2017: 120 days median2018: 82 days median2019: 89 days median2020: 88 days median2021: 85 days median2022: 149 days median2023: 55 days median2024: 74 days median2025: 97 days median2026 (partial year): 98 days median
2007high 168 (2016) · low 27 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OUR

1in 2025

2025: 12026 (partial year): 1
2007high 1 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OUR

10in 2025

2011: 62012: 812013: 962014: 1462015: 1192016: 1222017: 1572018: 1372019: 1752020: 1482021: 1542022: 232023: 72024: 152025: 10
2007high 175 (2019) · low 0 (2007)2025

MAUDE reports naming product code OUR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20091—00
20101—00
201132706
20122—081
20134103096
20143910146
201581110119
201661680122
201741200157
20187820137
20197890175
20207880148
20219850154
202214149023
2023205507
20241574015
20251497110
20266981—

What is it indicated for?

The Slmmetry TM Sacroiliac Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K111801: Simmetry (TM) Sacroiliac Joint Fusion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111801

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026