510(k) Report

510(k) · Cleared

Cleared

Easyscan Model 1.2

K111988510(k) TraditionalCleared Oct 28, 2011107-day reviewClass II21 CFR 886.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

I-Optics BV · MYC Ophthalmoscope, Laser, Scanning

Cleared on Oct 28, 2011 after a 107-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 9 later devices descend from it.

Decided
Oct 28, 2011
Review
107 days
Class
Class II
Product code
MYC
Recalls
None
Predicates
0

9 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2015: 1 descendant cleared2019: 1 descendant cleared2018: 2 descendants cleared2025: 2 descendants cleared2021: 2 descendants cleared2010201520202025
  1. This deviceK111988 Easyscan Model 1.2I-Optics BV · 2011
  2. Descendant · cites it directly · 8 of its ownK142047 EIDONCentervue S.P.A. · 2014
  3. Descendant · 2 generations on · 2 of its ownK180526 Eidon FACentervue S.P.A. · 2018
  4. Descendant · 3 generations on · 1 of its ownK211328 Eidon FA, Eidon, Eidon AF, Eidon UwflCentervue S.P.A. · 2021
  5. Descendant · 2 generations on · 1 of its ownK192113 DRSplusCentervue S.P.A. · 2019
  6. Descendant · 2 generations on · 1 of its ownK150320 CompassCentervue S.P.A. · 2015

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2014: 12015: 12018: 22019: 12021: 22025: 2
2014high 2 (2018) · low 0 (2016)2026

Most influential descendants

Showing 5 of 9 · See all
  • K142047EIDONCentervue S.P.A. · 2014 · cites it directly8descendants
  • K180526Eidon FACentervue S.P.A. · 2018 · 2 generations on2descendants
  • K211328Eidon FA, Eidon, Eidon AF, Eidon UwflCentervue S.P.A. · 2021 · 3 generations on1descendant
  • K192113DRSplusCentervue S.P.A. · 2019 · 2 generations on1descendant
  • K150320CompassCentervue S.P.A. · 2015 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K111988Easyscan Model 1.2I-Optics BV2011—
+1K142047EIDONCentervue S.P.A.2014—
+2K180526Eidon FACentervue S.P.A.2018—
+3K211328Eidon FA, Eidon, Eidon AF, Eidon UwflCentervue S.P.A.2021—
+2K192113DRSplusCentervue S.P.A.2019—
+2K150320CompassCentervue S.P.A.2015—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201510
201820
201910
202120
202520
FIG. 1 — Lineage of K111988, 2011–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MYC device

  1. #1 K261255 Kowa FM-600score 12.3 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (9)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142047EIDONCentervue S.P.A.20148

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K142047 (Centervue S.P.A., 2014) has gone furthest, with 8 descendants of its own.

How does its category compare?

All MYC devices

MYC Ophthalmoscope, Laser, Scanning: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MYC

2in 2025

2008: 12009: 32010: 22011: 22013: 12014: 22015: 22016: 12018: 22019: 12021: 22025: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MYC

116in 2009

2009: 116 days median
2007high 116 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MYC

No recall names MYC since 2007.

Adverse event reports per year · MYC

2in 2023

2021: 12023: 2
2007high 2 (2023) · low 0 (2007)2025

MAUDE reports naming product code MYC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
2009311600
20102—00
20112—00
20120—00
20131—00
20142—00
20152—00
20161—00
20170—00
20182—00
20191—00
20200—00
20212—01
20220—00
20230—02
20240—00
20252—00
20261—0—
Cite this page

510(k) Report. “K111988: Easyscan Model 1.2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111988

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026