K112127510(k) TraditionalCleared May 16, 2012296-day reviewClass II21 CFR 878.4780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew, Inc. · OMP Negative Pressure Wound Therapy Powered Suction Pump

Cleared on May 16, 2012 as substantially equivalent to K080275 (Iasis Medical, Inc., 2008) and 2 other predicates after a 296-day review. Its family tree reaches back 7 generations to 1995. 25 later devices descend from it.

Decided
May 16, 2012
Review
296 days
Class
Class II
Product code
OMP
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K945062 (1995). 22 ancestors in all, the oldest K933902 (1994). 25 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2008: 2 other ancestors2010: 1 other ancestor2007: 2 other ancestors2006: 3 other ancestors2003: 1 other ancestor1999: 1 other ancestor2005: 1 other ancestor2000: 1 other ancestor1997: 1 other ancestor2002: 1 other ancestor1994: 1 other ancestor2017: 5 descendants cleared2016: 1 descendant cleared2018: 5 descendants cleared2020: 3 descendants cleared2021: 2 descendants cleared2022: 3 descendants cleared2026: 1 descendant cleared2019: 3 descendants cleared2023: 1 descendant cleared2025: 1 descendant clearedK945062 · Vacplus · Kinetic Concepts, Inc. · 1995K042134 · Versatile 1 Wound Vacuum System · Blue Sky Medical Group Incorporated · 2004 · recalledK052456 · Modification to Versatile 1 Wound Vacuum System · Blue Sky Medical Group Incorporated · 2005K061919 · Versatile 1 Ezcare Wound Vacuum System · Blue Sky Medical Group Incorporated · 2007 · recalledK082426 · Renasys EZ · Smith & Nephew, Inc. · 2008 · recalledK083375 · Renasys GO Negative Pressure Wound Therapy · Smith & Nephew, Inc. · 2009 · recalledK111170 · PICO · Smith & Nephew, Inc. · 20111990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 5 other ancestors3 generations back: 4 other ancestors4 generations back: 3 other ancestors5 generations back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 10 descendants3 generations forward: 8 descendants4 generations forward: 3 descendants5 generations forward: 1 descendant K111170 · PICO · Smith & Nephew, Inc. · 2011K083375 · Renasys GO Negative Pressure Wound Therapy · Smith & Nephew, Inc. · 2009 · recalledK082426 · Renasys EZ · Smith & Nephew, Inc. · 2008 · recalledK061919 · Versatile 1 Ezcare Wound Vacuum System · Blue Sky Medical Group Incorporated · 2007 · recalledK052456 · Modification to Versatile 1 Wound Vacuum System · Blue Sky Medical Group Incorporated · 2005K042134 · Versatile 1 Wound Vacuum System · Blue Sky Medical Group Incorporated · 2004 · recalledK945062 · Vacplus · Kinetic Concepts, Inc. · 1995−50+5
  1. Root · 7 generations backK945062 VacplusKinetic Concepts, Inc. · 1995
  2. 6 generations backK042134 Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2004 · Recalled
  3. 5 generations backK052456 Modification to Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2005
  4. 4 generations backK061919 Versatile 1 Ezcare Wound Vacuum SystemBlue Sky Medical Group Incorporated · 2007 · Recalled
  5. 3 generations backK082426 Renasys EZSmith & Nephew, Inc. · 2008 · Recalled
  6. 2 generations backK083375 Renasys GO Negative Pressure Wound TherapySmith & Nephew, Inc. · 2009 · Recalled
  7. 1 generation backK111170 PICOSmith & Nephew, Inc. · 2011
  8. This deviceK112127 Pico Single Use Negative Pressure Wound Therapy SystemSmith & Nephew, Inc. · 2012
  9. Descendant · cites it directly · 23 of its ownK151436 PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical, Ltd. · 2016
  10. Descendant · cites it directly · 11 of its ownK163387 PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2017
  11. Descendant · 2 generations on · 8 of its ownK172005 PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2018
  12. Descendant · 2 generations on · 6 of its ownK180698 PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2018
  13. Descendant · 2 generations on · 4 of its ownK161599 UNO Negative Pressure Wound Therapy SystemGenadyne Biotechnologies, Inc. · 2017

Showing 5 of 25 descendants. See all descendants

Descendants cleared per year

2016: 12017: 52018: 52019: 32020: 32021: 22022: 32023: 12025: 12026: 1
2016high 5 (2017) · low 0 (2024)2026

Most influential descendants

Showing 5 of 25 · See all
  • K151436PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical, Ltd. · 2016 · cites it directly23descendants
  • K163387PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2017 · cites it directly11descendants
  • K172005PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2018 · 2 generations on8descendants
  • K180698PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited · 2018 · 2 generations on6descendants
  • K161599UNO Negative Pressure Wound Therapy SystemGenadyne Biotechnologies, Inc. · 2017 · 2 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K945062VacplusKinetic Concepts, Inc.1995—
−6K042134Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated20042
−5K052456Modification to Versatile 1 Wound Vacuum SystemBlue Sky Medical Group Incorporated2005—
−4K061919Versatile 1 Ezcare Wound Vacuum SystemBlue Sky Medical Group Incorporated20071
−3K082426Renasys EZSmith & Nephew, Inc.20084
−2K083375Renasys GO Negative Pressure Wound TherapySmith & Nephew, Inc.20092
−1K111170PICOSmith & Nephew, Inc.2011—
0 (this device)K112127Pico Single Use Negative Pressure Wound Therapy SystemSmith & Nephew, Inc.2012—
+1K151436PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical, Ltd.2016—
+1K163387PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited2017—
+2K172005PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited2018—
+2K180698PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited2018—
+2K161599UNO Negative Pressure Wound Therapy SystemGenadyne Biotechnologies, Inc.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710
199910
200010
200210
200310
200510
200630
200720
200820
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201750
201850
201930
202030
202120
202230
202310
202510
202610
FIG. 1 — Lineage of K112127, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OMP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OMP device

  1. #1 K260646 Renasys Edge (66803126)score 15.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080275NPD 1000 Negative Pressure Wound Therapy System
Summary page 1
…) Product Classification/Code: Class II, OMP 4. Date Prepared: May. 15, 2012 5. Predicate Device Information: NPID 1000 Negative Pressure Wound Therapy System (K080275) Kalypto Medical 6393 Oakgreen Avenue Hastings, MN 55033 Renasys Go (K083375) Smith & Nephew, Inc. St. Petersburg, F…
Iasis Medical, Inc.2008—
*K083375Renasys GO Negative Pressure Wound Therapy
Summary page 1
…Predicate Device Information: NPID 1000 Negative Pressure Wound Therapy System (K080275) Kalypto Medical 6393 Oakgreen Avenue Hastings, MN 55033 Renasys Go (K083375) Smith & Nephew, Inc. St. Petersburg, FL PICO Single Use Negative Pressure Wound Therapy System (K1 11170) Smith & Nephe…
Smith & Nephew, Inc.20092
*K111170PICO
Cleared while this submission was under review
Summary page 1
…6393 Oakgreen Avenue Hastings, MN 55033 Renasys Go (K083375) Smith & Nephew, Inc. St. Petersburg, FL PICO Single Use Negative Pressure Wound Therapy System (K1 11170) Smith & Nephew, Inc. St, Petersburg, FL…
Smith & Nephew, Inc.2011—

Also cleared against K080275: 3 other devices →

What descends from it? (25)

See all 25

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K151436PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical, Ltd.201623
K163387PICO Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited201711
K161432MyNeWT Negative Pressure Wound Therapy SystemStortford Medical, LLC20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 1.3 years on median.
  • 10 of the 22 ancestors have a recall of any class.
  • Of its descendants, K151436 (Smith & Nephew Medical, Ltd., 2016) has gone furthest, with 23 descendants of its own.
  • 3 other devices also cite its predicate K080275.

How does its category compare?

All OMP devices

OMP Negative Pressure Wound Therapy Powered Suction Pump: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · OMP

5in 2025

2007: 62008: 82009: 82010: 62011: 62012: 112013: 112014: 102015: 202016: 192017: 112018: 132019: 152020: 62021: 92022: 102023: 82024: 92025: 52026 (partial year): 9
2007high 20 (2015) · low 5 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OMP

127in 2025

2007: 113 days median2008: 98 days median2009: 87 days median2010: 97 days median2011: 123 days median2012: 292 days median2013: 84 days median2014: 179 days median2015: 189 days median2016: 146 days median2017: 137 days median2018: 214 days median2019: 249 days median2020: 179 days median2021: 238 days median2022: 229 days median2023: 291 days median2024: 181 days median2025: 127 days median2026 (partial year): 141 days median
2007high 292 (2012) · low 84 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OMP

2in 2024

2009: 72010: 32012: 12013: 22014: 42015: 12016: 22019: 12024: 2
2007high 7 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OMP

140in 2025

2007: 12008: 12009: 792010: 802011: 1302012: 972013: 1692014: 2292015: 3782016: 3982017: 3682018: 4222019: 9942020: 3,6642021: 1,4222022: 2582023: 1432024: 1352025: 140
2007high 3,664 (2020) · low 1 (2007)2025

MAUDE reports naming product code OMP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611301
200889801
2009887779
2010697380
201161230130
201211292197
201311842169
2014101794229
2015201891378
2016191462398
2017111370368
2018132140422
2019152491994
2020617903,664
2021923801,422
2022102290258
202382910143
202491812135
202551270140
202691410—

What is it indicated for?

PICO is indicated for patients who would benefit from a suction device (negative pressure wound therapy) as it may promote wound healing via removal of low to moderate levels of exudate and infectious materials.

Examples of appropriate wound types include:

* Chronic

* Acute

* Traumatic

* Subacute and dehisced wounds

* Partial-thickness burns

* Ulcers (such as diabetic or pressure)

* Flaps and grafts

* Closed surgical incisions

PICO Single Use Negative Pressure Wound Therapy System is suitable for use both in a hospital and homecare setting.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112127: Pico Single Use Negative Pressure Wound Therapy System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112127

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026