510(k) · Cleared
ClearedArrow Reverse Shoulder System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fournitures Hospitalieres Industrie · PHX Shoulder Prosthesis, Reverse Configuration
Cleared on Jul 12, 2012 as substantially equivalent to K053274 (Zimmer GmbH, 2006) and 4 other predicates after a 349-day review. Its family tree reaches back 10 generations to 1991. 10 later devices descend from it.
- Decided
- Jul 12, 2012
- Review
- 349 days
- Class
- Class II
- Product code
- PHX
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 10 generations to K911686 (1991). 61 ancestors in all, the oldest K790987 (1979). 10 later devices descend from it, 8 citing it directly.
- Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 6 generations between
- 3 generations backK060704 Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc. · 2006 · Recalled
- 2 generations backK063569 Equinoxe Reverse Shoulder SystemExactech, Inc. · 2007 · Recalled
- 1 generation backK073688 Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and…Exactech, Inc. · 2008 · Recalled
- This deviceK112193 Arrow Reverse Shoulder SystemFournitures Hospitalieres Industrie · 2012
- Descendant · cites it directly · 5 of its ownK142778 ARROW Reverse Shoulder long keel and short keel glenoid baseFournitures Hospitalieres Industrie · 2015
- Descendant · cites it directly · 4 of its ownK162068 ARROW Anatomical Porous glenoidFournitures Hospitalieres Industrie · 2017
- Descendant · cites it directly · 4 of its ownK150568 ARROW Humeral stems size 6 and 16Fournitures Hospitalieres Industrie · 2015
- Descendant · cites it directly · 3 of its ownK171789 ARROW Reverse Porous GlenoidFournitures Hospitalieres Industrie · 2018
- Descendant · cites it directly · 2 of its ownK202024 ARROW Short Stem Humeral SystemFH Industrie · 2021
Show all 10 generations
- Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 9 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
- 8 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
- 7 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
- 6 generations backK030941 Aequalis Reversed Shoulder ProsthesisTornier · 2004
- 5 generations backK041873 Aequalis Reversed Shoulder ProsthesisTornier · 2004
- 4 generations backK052906 Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc. · 2005 · Recalled
- 3 generations backK060704 Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc. · 2006 · Recalled
- 2 generations backK063569 Equinoxe Reverse Shoulder SystemExactech, Inc. · 2007 · Recalled
- 1 generation backK073688 Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and…Exactech, Inc. · 2008 · Recalled
- This deviceK112193 Arrow Reverse Shoulder SystemFournitures Hospitalieres Industrie · 2012
Showing 5 of 10 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 10 · See all- K142778ARROW Reverse Shoulder long keel and short keel glenoid baseFournitures Hospitalieres Industrie · 2015 · cites it directly5descendants
- K162068ARROW Anatomical Porous glenoidFournitures Hospitalieres Industrie · 2017 · cites it directly4descendants
- K150568ARROW Humeral stems size 6 and 16Fournitures Hospitalieres Industrie · 2015 · cites it directly4descendants
- K171789ARROW Reverse Porous GlenoidFournitures Hospitalieres Industrie · 2018 · cites it directly3descendants
- K202024ARROW Short Stem Humeral SystemFH Industrie · 2021 · cites it directly2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K911686 | Global Total Shoulder, Uncement Humeral Hemi-Shoul | Depuy, Inc. | 1991 | — |
| −9 | K984541 | Global FX Humeral Stem, Global Advantage Humeral Head | DePuy Orthopaedics, Inc. | 1999 | — |
| −8 | K992065 | Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage… | DePuy Orthopaedics, Inc. | 1999 | — |
| −7 | K021478 | Delta Shoulder | Depuy, Inc. | 2003 | — |
| −6 | K030941 | Aequalis Reversed Shoulder Prosthesis | Tornier | 2004 | — |
| −5 | K041873 | Aequalis Reversed Shoulder Prosthesis | Tornier | 2004 | — |
| −4 | K052906 | Zimmer Trabecular Metal Reverse Shoulder System | Zimmer, Inc. | 2005 | 12 |
| −3 | K060704 | Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MM | Zimmer, Inc. | 2006 | 10 |
| −2 | K063569 | Equinoxe Reverse Shoulder System | Exactech, Inc. | 2007 | 13 |
| −1 | K073688 | Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and Locking Screw | Exactech, Inc. | 2008 | 1 |
| 0 (this device) | K112193 | Arrow Reverse Shoulder System | Fournitures Hospitalieres Industrie | 2012 | — |
| +1 | K142778 | ARROW Reverse Shoulder long keel and short keel glenoid base | Fournitures Hospitalieres Industrie | 2015 | — |
| +1 | K162068 | ARROW Anatomical Porous glenoid | Fournitures Hospitalieres Industrie | 2017 | — |
| +1 | K150568 | ARROW Humeral stems size 6 and 16 | Fournitures Hospitalieres Industrie | 2015 | — |
| +1 | K171789 | ARROW Reverse Porous Glenoid | Fournitures Hospitalieres Industrie | 2018 | — |
| +1 | K202024 | ARROW Short Stem Humeral System | FH Industrie | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1980 | 2 | 0 |
| 1986 | 1 | 0 |
| 1987 | 2 | 0 |
| 1989 | 1 | 0 |
| 1992 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
| 1995 | 2 | 0 |
| 1996 | 5 | 0 |
| 1998 | 3 | 0 |
| 1999 | 5 | 0 |
| 2000 | 6 | 0 |
| 2001 | 5 | 0 |
| 2003 | 2 | 0 |
| 2004 | 3 | 0 |
| 2005 | 5 | 0 |
| 2006 | 3 | 0 |
| 2007 | 1 | 0 |
| 2010 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2015 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PHX device
- #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K053274 | Anatomical Shoulder Inverse/ReverseSummary page 5…Information on devices to which substantial equivalence is claimed: Manufacturer: Zimmer . Device Trade Name: Anatomical Shoulder® Inverse/Reverse . system 510 (K): K053274 Manufacturer: Exactech, Inc. - Device Trade Name: Equinoxe™ Reverse Shoulder system 510 (K): K073688/K063569 Manufacturer: De… | 2006 |
| * | K073688 | Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and Locking ScrewSummary page 5…ade Name: Anatomical Shoulder® Inverse/Reverse . system 510 (K): K053274 Manufacturer: Exactech, Inc. - Device Trade Name: Equinoxe™ Reverse Shoulder system 510 (K): K073688/K063569 Manufacturer: Depuy Device Trade Name: Delta Xtend™ Reverse Shoulder system. 510 (K): K062250 Manufacturer: Fournitur… | 2008 |
| * | K063569 | Equinoxe Reverse Shoulder SystemSummary page 5…: Anatomical Shoulder® Inverse/Reverse . system 510 (K): K053274 Manufacturer: Exactech, Inc. - Device Trade Name: Equinoxe™ Reverse Shoulder system 510 (K): K073688/K063569 Manufacturer: Depuy Device Trade Name: Delta Xtend™ Reverse Shoulder system. 510 (K): K062250 Manufacturer: Fournitures Hospi… | 2007 |
| * | K062250 | Delta Xtend Reverse Shoulder SystemSummary page 5…Device Trade Name: Equinoxe™ Reverse Shoulder system 510 (K): K073688/K063569 Manufacturer: Depuy Device Trade Name: Delta Xtend™ Reverse Shoulder system. 510 (K): K062250 Manufacturer: Fournitures Hospitaliéres Industrie ARROW?® Anatomical shoulder system K093599 S-5. Device Description: The ARR… | 2007 |
| * | K093599 | Arrow Anatomical Shoulder SystemSummary page 5…Depuy Device Trade Name: Delta Xtend™ Reverse Shoulder system. 510 (K): K062250 Manufacturer: Fournitures Hospitaliéres Industrie ARROW?® Anatomical shoulder system K093599 S-5. Device Description: The ARROW® reverse shoulder system is a shoulder joint prosthesis, composed of the following elements… | 2010 |
What descends from it? (10)
8 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K142778 | ARROW Reverse Shoulder long keel and short keel glenoid base | 2015 | 5 |
| K162068 | ARROW Anatomical Porous glenoid | 2017 | 4 |
| K150568 | ARROW Humeral stems size 6 and 16 | 2015 | 4 |
| K171789 | ARROW Reverse Porous Glenoid | 2018 | 3 |
| K202024 | ARROW Short Stem Humeral System | 2021 | 2 |
| K253345 | JARVIS Diaphyseal Stem Standard | 2025 | 1 |
| K242253 | JARVIS Glenoid Reverse Shoulder Prosthesis | 2024 | 1 |
| K232226 | ARROW Off-Centred Humeral Insert | 2023 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 1.0 years on median.
- 17 of the 61 ancestors have a recall of any class.
- Of its descendants, K142778 (Fournitures Hospitalieres Industrie, 2015) has gone furthest, with 5 descendants of its own.
- 12 other devices also cite its predicate K053274.
How does its category compare?
All PHX devicesPHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · PHX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PHX
72in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PHX
3in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PHX
2,848in 2025
MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 97 | 0 | 0 |
| 2008 | 6 | 79 | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 8 | 124 | 0 | 0 |
| 2011 | 12 | 94 | 0 | 0 |
| 2012 | 12 | 114 | 0 | 0 |
| 2013 | 8 | 143 | 0 | 0 |
| 2014 | 12 | 110 | 0 | 0 |
| 2015 | 4 | 206 | 2 | 14 |
| 2016 | 4 | 132 | 0 | 5 |
| 2017 | 11 | 141 | 0 | 25 |
| 2018 | 14 | 127 | 1 | 323 |
| 2019 | 9 | 144 | 3 | 504 |
| 2020 | 13 | 143 | 3 | 986 |
| 2021 | 21 | 143 | 8 | 1,404 |
| 2022 | 9 | 198 | 0 | 1,342 |
| 2023 | 9 | 154 | 7 | 1,401 |
| 2024 | 9 | 139 | 1 | 2,142 |
| 2025 | 9 | 72 | 3 | 2,848 |
| 2026 | 18 | 130 | 7 | — |
What is it indicated for?
The ARROW® reverse shoulder prosthesis is indicated for patients with severe shoulder arthropathy and a grossly deficient rotator cuff or a previously failed shoulder joint replacement with a grossly deficient rotator cuff. A functional deltoid muscle and adequate glenoid bone stock are necessary to use this device. The humeral stem is intended for cemented of cementless application while the metal-back glenoid baseplate is intended for cementless application with the addition of bone screws for fixation.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K112193 · printed Nov 6, 2026
Cite this page
510(k) Report. “K112193: Arrow Reverse Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112193
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026