510(k) Report

510(k) · Cleared

Recalled · Class II · 2015

Sarn Centrifugal Pump

K112229510(k) TraditionalCleared Dec 9, 2011128-day reviewClass II21 CFR 870.4360Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Terumo Cardiovascular Systems · KFM Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type

Cleared on Dec 9, 2011 as substantially equivalent to K020998 (Terumo Cardiovascular Systems Corp., 2002) and 1 other predicate after a 128-day review. Its family tree reaches back 2 generations to 1993. 1 later device descends from it. It has been recalled 4 times.

Decided
Dec 9, 2011
Review
128 days
Class
Class II
Product code
KFM
Recalls
4
Predicates
2

Its longest line of descent runs back 2 generations to K915363 (1993). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2013: 1 descendant clearedK915363 · Sarns 7850 Centrifugal Pump (Modified) · 3M Health Care, Ltd. · 1993 · recalledK020998 · Sarns Centrifugal Pump with Xcoating, Model 164275X · Terumo Cardiovascular Systems Corp. · 2002 · recalled1990200020102020
  1. Root · 2 generations backK915363 Sarns 7850 Centrifugal Pump (Modified)3M Health Care, Ltd. · 1993 · Recalled
  2. 1 generation backK020998 Sarns Centrifugal Pump with Xcoating, Model 164275XTerumo Cardiovascular Systems Corp. · 2002 · Recalled
  3. This deviceK112229 Sarn Centrifugal PumpTerumo Cardiovascular Systems · 2011
  4. Descendant · cites it directly · 0 of its ownK132712 Affinity CP Centrifugal Blood Pump with or Without Coating, Affinity…Medtronic, Inc. · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K132712Affinity CP Centrifugal Blood Pump with or Without Coating, Affinity CP AdapterMedtronic, Inc. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K915363Sarns 7850 Centrifugal Pump (Modified)3M Health Care, Ltd.19931
−1K020998Sarns Centrifugal Pump with Xcoating, Model 164275XTerumo Cardiovascular Systems Corp.20022
0 (this device)K112229Sarn Centrifugal PumpTerumo Cardiovascular Systems2011—
+1K132712Affinity CP Centrifugal Blood Pump with or Without Coating, Affinity CP AdapterMedtronic, Inc.2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K112229, 1993–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KFM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KFM device

  1. #1 K250326 Quantum Perfusion Centrifugal Blood Pump…score 11.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020998Sarns Centrifugal Pump with Xcoating, Model 164275X
Summary page 1
…870.4360 Product Code(s) KFM Legally marketed device(s) to Sarns® Centrifugal Pump (With or without X-Coating Tm ) which equivalence is claimed (K020998 & K9 15363) Section 6- Page 1 of 6 @ T.FRUMQf Terumo Cardiovascular Systems Corporation…
Terumo Cardiovascular Systems Corp.20022
*K915363Sarns 7850 Centrifugal Pump (Modified)
Summary page 1
…Product Code(s) KFM Legally marketed device(s) to Sarns® Centrifugal Pump (With or without X-Coating Tm ) which equivalence is claimed (K020998 & K9 15363) Section 6- Page 1 of 6 @ T.FRUMQf Terumo Cardiovascular Systems Corporation…
3M Health Care, Ltd.19931

Also cleared against K020998: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K132712Affinity CP Centrifugal Blood Pump with or Without Coating, Affinity CP AdapterMedtronic, Inc.20130

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 27, 2015Class IIZ-1235-2017Process controlTerumo Cardiovascular Systems Corporation has received complaints indicating that the Sarns Centrifugal Pump (disposable pump heads) have exhibited leaks. The leaks were detected during priming of the bypass circuit and during CPB…
Apr 14, 2014Class IIZ-2029-2014Device DesignDuring set-up and priming of the bypass circuit, leaks were detected on the centrifugal pumphead.
Apr 14, 2014Class IIZ-2028-2014Device DesignDuring set-up and priming of the bypass circuit, leaks were detected on the centrifugal pumphead.
Apr 14, 2014Class IIZ-2030-2014Device DesignDuring set-up and priming of the bypass circuit, leaks were detected on the centrifugal pumphead.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 9.7 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • Of its descendants, K132712 (Medtronic, Inc., 2013) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K020998.

How does its category compare?

All KFM devices

KFM Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · KFM

2in 2025

2008: 42009: 52010: 32011: 72013: 22017: 12019: 32020: 32021: 32023: 32025: 2
2007high 7 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KFM

30in 2023

2008: 194 days median2009: 184 days median2010: 109 days median2011: 16 days median2019: 147 days median2020: 30 days median2021: 534 days median2023: 30 days median
2007high 534 (2021) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KFM

2in 2024

2008: 22009: 42010: 22011: 12012: 52018: 12019: 3, 1 Class I2024: 2
2007high 5 (2012) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · KFM

249in 2025

2007: 602008: 622009: 852010: 812011: 572012: 822013: 1042014: 3472015: 2992016: 1562017: 1212018: 1762019: 3112020: 4372021: 4462022: 2942023: 3462024: 2962025: 249
2007high 446 (2021) · low 57 (2011)2025

MAUDE reports naming product code KFM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—060
20084194262
20095184485
20103109281
2011716157
20120—582
20132—0104
20140—0347
20150—0299
20160—0156
20171—0121
20180—1176
201931473 (1)311
20203300437
202135340446
20220—0294
20233300346
20240—2296
20252—0249
20260—0—

What is it indicated for?

The Sarns® Centrifugal Pump with or without X-CoatingTM is a sterile, single use device, used as an extracorporeal blood pump for use in cardiopulmonary bypass procedures for up to 6 hours.

The pump is intended for use with the Sarns@ Centrifugal Systems or may be used with Stockert Centrifugal Pump Systems by attaching the Sarns® Centrifugal Pump Adapter.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112229: Sarn Centrifugal Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112229

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026