510(k) Report

510(k) · Cleared

Cleared

Digital Radiography

K112309510(k) SpecialCleared Sep 2, 201122-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Canon Inc. -Medical Equipment Group · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Sep 2, 2011 as substantially equivalent to K103591 (Canon Inc. -Medical Equipment Group, 2011) and 1 other predicate after a 22-day review. Its family tree reaches back 8 generations to 1998. 22 later devices descend from it.

Decided
Sep 2, 2011
Review
22 days
Class
Class II
Product code
MQB
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K981556 (1998). 14 ancestors in all. 22 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2009: 1 other ancestor2006: 1 other ancestor2005: 1 other ancestor2002: 1 other ancestor2008: 1 other ancestor2003: 1 other ancestor2016: 1 descendant cleared2013: 1 descendant cleared2025: 2 descendants cleared2017: 2 descendants cleared2014: 1 descendant cleared2019: 2 descendants cleared2022: 8 descendants cleared2021: 3 descendants cleared2018: 1 descendant cleared2023: 1 descendant clearedK981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalledK103591 · Digital Radiography · Canon Inc. -Medical Equipment Group · 20111995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 4 other ancestors3 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 4 descendants3 generations forward: 7 descendants4 generations forward: 4 descendants5 generations forward: 3 descendants6 generations forward: 2 descendants K103591 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2011K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalledK091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998−50+5
  1. Root · 8 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 7 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
  3. 6 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
  4. 5 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
  5. 4 generations backK060433 Digital Radiography Cxdi-50CCanon, Inc. · 2006
  6. 3 generations backK091545 Digital Radiography Cxdi-60CCanon, Inc. · 2009
  7. 2 generations backK102012 Digital RadiographyCanon Inc. -Medical Equipment Group · 2010 · Recalled
  8. 1 generation backK103591 Digital RadiographyCanon Inc. -Medical Equipment Group · 2011
  9. This deviceK112309 Digital RadiographyCanon Inc. -Medical Equipment Group · 2011
  10. Descendant · cites it directly · 21 of its ownK131106 Digital Radiography Cxdi-701C Wireless, Digital Radiography…Canon, Inc. · 2013
  11. Descendant · 2 generations on · 15 of its ownK170332 Digital Radiography Cxdi-710C Wireless, Digital Radiography…Canon, Inc. · 2017
  12. Descendant · 2 generations on · 6 of its ownK133693 Digital Radiography Cxdi-401C WirelessCanon, Inc. · 2014
  13. Descendant · 3 generations on · 3 of its ownK212553 DIGITAL RADIOGRAPHY CXDI-Pro, D1Canon, Inc. · 2021
  14. Descendant · 3 generations on · 3 of its ownK192632 DIGITAL RADIOGRAPHY CXDI-702C Wireless, DIGITAL RADIOGRAPHY…Canon, Inc. · 2019

Showing 5 of 22 descendants. See all descendants

Descendants cleared per year

2013: 12014: 12016: 12017: 22018: 12019: 22021: 32022: 82023: 12025: 2
2013high 8 (2022) · low 0 (2015)2026

Most influential descendants

Showing 5 of 22 · See all
  • K131106Digital Radiography Cxdi-701C Wireless, Digital Radiography Cxdi-70IG Wireless, Digital…Canon, Inc. · 2013 · cites it directly21descendants
  • K170332Digital Radiography Cxdi-710C Wireless, Digital Radiography Cxdi-810C WirelessCanon, Inc. · 2017 · 2 generations on15descendants
  • K133693Digital Radiography Cxdi-401C WirelessCanon, Inc. · 2014 · 2 generations on6descendants
  • K212553DIGITAL RADIOGRAPHY CXDI-Pro, D1Canon, Inc. · 2021 · 3 generations on3descendants
  • K192632DIGITAL RADIOGRAPHY CXDI-702C Wireless, DIGITAL RADIOGRAPHY CXDI-402C WirelessCanon, Inc. · 2019 · 3 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K981556Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc.1998—
−7K992547Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc.1999—
−6K023750Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc.2002—
−5K031447Canon, Digital Radiography, Model Cxdi-50GCanon, Inc.2003—
−4K060433Digital Radiography Cxdi-50CCanon, Inc.2006—
−3K091545Digital Radiography Cxdi-60CCanon, Inc.2009—
−2K102012Digital RadiographyCanon Inc. -Medical Equipment Group20101
−1K103591Digital RadiographyCanon Inc. -Medical Equipment Group2011—
0 (this device)K112309Digital RadiographyCanon Inc. -Medical Equipment Group2011—
+1K131106Digital Radiography Cxdi-701C Wireless, Digital Radiography Cxdi-70IG…Canon, Inc.2013—
+2K170332Digital Radiography Cxdi-710C Wireless, Digital Radiography Cxdi-810C WirelessCanon, Inc.2017—
+2K133693Digital Radiography Cxdi-401C WirelessCanon, Inc.2014—
+3K212553DIGITAL RADIOGRAPHY CXDI-Pro, D1Canon, Inc.2021—
+3K192632DIGITAL RADIOGRAPHY CXDI-702C Wireless, DIGITAL RADIOGRAPHY CXDI-402C WirelessCanon, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200510
200610
200810
200910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201410
201610
201720
201810
201920
202130
202280
202310
202520
FIG. 1 — Lineage of K112309, 1998–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K103591Digital Radiography
Summary page 1
…New Model Canon DIGITAL RADIOGRAPHY CXDI-80C Wireless DIGITAL RADIOGRAPHY CXDI-80G Wircless 90MQB, Solid State X-ray Imager To be assigned FDA 510(k) #/Model Name: K103591/ DIGITAL RADIOGRAPHY CXDI-401G Classification Name:. Description of Device: The DIGITAL RADIOGRAPHY CXDI-80C Wireless and CXDI…
Canon Inc. -Medical Equipment Group2011—
*K102012Digital Radiography
Summary page 1
…l Name: K103591/ DIGITAL RADIOGRAPHY CXDI-401G Classification Name:. Description of Device: The DIGITAL RADIOGRAPHY CXDI-80C Wireless and CXDI-80G Wireless are solid K102012/ DIGITAL RADIOGRAPHY CXDI-70C Wireless 90MQB, Solid State X-ray Imager state x-ray imagers which have 27x35cm imaging area. The…
Canon Inc. -Medical Equipment Group20101

Also cleared against K103591: 3 other devices →

What descends from it? (22)

See all 22

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131106Digital Radiography Cxdi-701C Wireless, Digital Radiography Cxdi-70IG Wireless, Digital…Canon, Inc.201321
K153312Scatter Correction for Cxdi SeriesCanon, Inc.20162

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 1.2 years on median.
  • 1 of the 14 ancestors has a recall of any class.
  • Of its descendants, K131106 (Canon, Inc., 2013) has gone furthest, with 21 descendants of its own.
  • 3 other devices also cite its predicate K103591.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

DIGITAL RADIOGRAPHY CXDI-80C Wireless and CXDI-80G Wireless provide digital image capture for conventional film/screen radiographic examinations.

These devices are intended to replace radiographic film/screen systems in all general purpose diagnostic procedures.

These devices are not intended for mammography applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K112309: Digital Radiography.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112309

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026