510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Access Thyroglobulin Anitbody

K112933510(k) SpecialCleared Dec 27, 201185-day reviewClass II21 CFR 866.5870Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Beckman Coulter, Inc. · JNL Immunochemical, Thyroglobulin Autoantibody

Cleared on Dec 27, 2011 as substantially equivalent to K062516 (Beckman Coulter, Inc., 2006) after an 85-day review. Its family tree reaches back 2 generations to 2001. 3 later devices descend from it. It has been recalled 2 times.

Decided
Dec 27, 2011
Review
85 days
Class
Class II
Product code
JNL
Recalls
2
Predicates
1

Its longest line of descent runs back 2 generations to K012208 (2001). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2023: 1 descendant cleared2025: 1 descendant cleared2024: 1 descendant clearedK012208 · Access Thyroglobulin Antibody and Calibrators on the Access Immunoassay Systems, Models 33890, 33895 · Beckman Coulter, Inc. · 2001 · recalledK062516 · Access Thyroglobulin Antibody II Assay, Models A32898 (Reagent) and A36920 (Calibrators) · Beckman Coulter, Inc. · 2006 · recalled200020052010201520202025
  1. Root · 2 generations backK012208 Access Thyroglobulin Antibody and Calibrators on the Access…Beckman Coulter, Inc. · 2001 · Recalled
  2. 1 generation backK062516 Access Thyroglobulin Antibody II Assay, Models A32898 (Reagent) and…Beckman Coulter, Inc. · 2006 · Recalled
  3. This deviceK112933 Access Thyroglobulin AnitbodyBeckman Coulter, Inc. · 2011
  4. Descendant · cites it directly · 1 of its ownK213517 Access Thyroglobulin Antibody IIBeckman Coulter, Inc. · 2023
  5. Descendant · cites it directly · 0 of its ownK250816 ADVIA Centaur Anti-Thyroglobulin II (aTgII)Siemens Healthcare Diagnostics, Inc. · 2025
  6. Descendant · 2 generations on · 0 of its ownK240996 Access Thyroglobulin Antibody IIBeckman Coulter, Inc. · 2024

Most influential descendants

Showing 3 of 3 · See all
  • K213517Access Thyroglobulin Antibody IIBeckman Coulter, Inc. · 2023 · cites it directly1descendant
  • K250816ADVIA Centaur Anti-Thyroglobulin II (aTgII)Siemens Healthcare Diagnostics, Inc. · 2025 · cites it directly0descendants
  • K240996Access Thyroglobulin Antibody IIBeckman Coulter, Inc. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K012208Access Thyroglobulin Antibody and Calibrators on the Access Immunoassay…Beckman Coulter, Inc.20011
−1K062516Access Thyroglobulin Antibody II Assay, Models A32898 (Reagent) and A36920…Beckman Coulter, Inc.20062
0 (this device)K112933Access Thyroglobulin AnitbodyBeckman Coulter, Inc.2011—
+1K213517Access Thyroglobulin Antibody IIBeckman Coulter, Inc.2023—
+1K250816ADVIA Centaur Anti-Thyroglobulin II (aTgII)Siemens Healthcare Diagnostics, Inc.2025—
+2K240996Access Thyroglobulin Antibody IIBeckman Coulter, Inc.2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202410
202510
FIG. 1 — Lineage of K112933, 2001–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JNL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JNL device

  1. #1 K250816 ADVIA Centaur Anti-Thyroglobulin II (aTgII)score 11.1 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K062516Access Thyroglobulin Antibody II Assay, Models A32898 (Reagent) and A36920 (Calibrators)
Summary page 1
…oglobulin Antibody Enzyme Immunoassay Classification Name: Immunochemnical, Thyroglobulin Autoantibody Predicate Device Access Thyroglobulin Antibody 11(k062516) Manufactured by Beckman Coulter, Inc. Device Description The Access Thyroglobulin Antibody 1…
Beckman Coulter, Inc.20062

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213517Access Thyroglobulin Antibody IIBeckman Coulter, Inc.20231
K250816ADVIA Centaur Anti-Thyroglobulin II (aTgII)Siemens Healthcare Diagnostics, Inc.20250

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 5, 2024Class IIZ-0265-2025Error in labelingIFUs for the device incorrectly states the biotin interference was remediated. The issue could result in potentially false-low results.
Apr 30, 2019Class IIZ-2242-2020OtherThe recalling firm characterized the potential interference effects of biotin (up to 1,200 ng/mL) on all biotin-mediated Access assays. The following six assays: Free T3-REF A13422, Total T3-REF 33830, Free T4-REF 33880, GI Mon-387687…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 1 company; a new generation was cleared every 5.2 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • Of its descendants, K213517 (Beckman Coulter, Inc., 2023) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JNL devices

JNL Immunochemical, Thyroglobulin Autoantibody: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JNL

1in 2025

2007: 12011: 12024: 12025: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JNL

Too few JNL 510(k)s in any year since 2007 to give a median.

Recalls per year · JNL

1in 2024

2010: 12011: 12024: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JNL

1in 2025

2009: 12011: 12012: 12015: 22021: 12022: 82025: 1
2007high 8 (2022) · low 0 (2007)2025

MAUDE reports naming product code JNL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—01
20100—10
20111—11
20120—01
20130—00
20140—00
20150—02
20160—00
20170—00
20180—00
20190—00
20200—00
20210—01
20220—08
20230—00
20241—10
20251—01
20260—0—

What is it indicated for?

The Access Thyroglobulin Antibody 11 assay is a paramagnetic chemiluminescent immunoassay for the quantitative determination of thyroglobulin antibody levels in human serum and plasma using the Access Immunoassay Systems. The measurement of thyroid autoantibodies may aid in the diagnosis of Hashimoto's disease, nontoxic goiter, and Graves' disease.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112933: Access Thyroglobulin Anitbody.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K112933

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026