510(k) Report

510(k) · Cleared

Cleared

Transcorp Spinal Access System

K113352510(k) TraditionalCleared Apr 16, 2012154-day reviewClass II21 CFR 888.1100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Transcorp, Inc. · HRX Arthroscope

Cleared on Apr 16, 2012 as substantially equivalent to K032891 (Trans1, Inc., 2004) after a 154-day review. Its family tree reaches back 1 generation to 2004.

Decided
Apr 16, 2012
Review
154 days
Class
Class II
Product code
HRX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K032891 (2004). No later device cites it as a predicate yet.

K032891 · TRANS1 Trans-Sacral Spinal Access and Preparation Kit · Trans1, Inc. · 200420002002200420062008201020122014
  1. Root · 1 generation backK032891 TRANS1 Trans-Sacral Spinal Access and Preparation KitTrans1, Inc. · 2004
  2. This deviceK113352 Transcorp Spinal Access SystemTranscorp, Inc. · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K032891TRANS1 Trans-Sacral Spinal Access and Preparation KitTrans1, Inc.2004—
0 (this device)K113352Transcorp Spinal Access SystemTranscorp, Inc.2012—
FIG. 1 — Lineage of K113352, 2004–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRX device

  1. #1 K260203 Fule Vertebroplasty Balloon Catheterscore 14.9 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032891TRANS1 Trans-Sacral Spinal Access and Preparation Kit
Summary page 1
…Set Classification: 21 CFR Section 888.1100, Arthroscope Product Code: HRX Substantially Eq~uivalent Device: K032891:- TranS 1 Trans-Sacral Spinal Access and Preparation Device Device Descrintion: The Transcorp Spinal Access S…
Trans1, Inc.2004—

Also cleared against K032891: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K032891.

How does its category compare?

All HRX devices

HRX Arthroscope: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · HRX

9in 2025

2007: 72008: 92009: 112010: 92011: 32012: 112013: 122014: 92015: 42016: 82017: 42018: 122019: 122020: 72021: 72022: 32023: 42024: 62025: 92026 (partial year): 7
2007high 12 (2013) · low 3 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRX

107in 2025

2007: 89 days median2008: 115 days median2009: 139 days median2010: 114 days median2011: 84 days median2012: 102 days median2013: 90 days median2014: 140 days median2015: 132 days median2016: 89 days median2017: 97 days median2018: 101 days median2019: 45 days median2020: 141 days median2021: 57 days median2022: 89 days median2023: 249 days median2024: 110 days median2025: 107 days median2026 (partial year): 217 days median
2007high 249 (2023) · low 45 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRX

1in 2024

2007: 32008: 132009: 232010: 122011: 62013: 42015: 72018: 12021: 32024: 1
2007high 23 (2009) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRX

2,076in 2025

2007: 4212008: 4412009: 5582010: 6122011: 6312012: 7782013: 6782014: 8022015: 7632016: 4692017: 9342018: 1,5812019: 1,6762020: 1,7062021: 1,9082022: 1,4062023: 1,8522024: 2,4272025: 2,076
2007high 2,427 (2024) · low 421 (2007)2025

MAUDE reports naming product code HRX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077893421
2008911513441
20091113923558
2010911412612
20113846631
2012111020778
201312904678
201491400802
201541327763
20168890469
20174970934
20181210111,581
2019124501,676
2020714101,706
202175731,908
202238901,406
2023424901,852
2024611012,427
2025910702,076
202672170—

What is it indicated for?

The Transcorp Spinal Access System is indicated for minimally invasive visualization and access to the anterior spine for assisting in various surgical procedures such as herniated disc repair, biopsy, and harvesting autogenous bone.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K113352: Transcorp Spinal Access System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K113352

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026