510(k) Report

510(k) · Cleared

Cleared

Ace Albumin Reagent Ace Total Protein Reagent Ace Calcium-Arsenazo Reagent Ace Phosphorus U.V. Reagent

K113374510(k) TraditionalCleared Jul 13, 2012240-day reviewClass II21 CFR 862.1035

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Alfa Wassermann Diagnostic Technologies, Inc. · CIX Bromcresol Green Dye-Binding, Albumin

Cleared on Jul 13, 2012 as substantially equivalent to K931786 (Schiapparelli Biosystems, Inc., 1993) after a 240-day review. Its family tree reaches back 1 generation to 1993. 1 later device descends from it.

Decided
Jul 13, 2012
Review
240 days
Class
Class II
Product code
CIX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K931786 (1993). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2013: 1 descendant clearedK931786 · Ace Clinical Chemistry System · Schiapparelli Biosystems, Inc. · 19931990200020102020
Descendants, by generation 1 generation forward: 1 descendant K931786 · Ace Clinical Chemistry System · Schiapparelli Biosystems, Inc. · 19930
  1. Root · 1 generation backK931786 Ace Clinical Chemistry SystemSchiapparelli Biosystems, Inc. · 1993
  2. This deviceK113374 Ace Albumin Reagent Ace Total Protein Reagent Ace Calcium-Arsenazo…Alfa Wassermann Diagnostic Technologies, Inc. · 2012
  3. Descendant · cites it directly · 0 of its ownK131488 Ace Albumin Reagent, Ace Total Protein Reagent, Ace Calcium-Arsenazo…Alfa Wassermann Diagnostics Technologies, LLC · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K131488Ace Albumin Reagent, Ace Total Protein Reagent, Ace Calcium-Arsenazo Reagent and Ace…Alfa Wassermann Diagnostics Technologies, LLC · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K931786Ace Clinical Chemistry SystemSchiapparelli Biosystems, Inc.1993—
0 (this device)K113374Ace Albumin Reagent Ace Total Protein Reagent Ace Calcium-Arsenazo Reagent Ace…Alfa Wassermann Diagnostic Technologies, Inc.2012—
+1K131488Ace Albumin Reagent, Ace Total Protein Reagent, Ace Calcium-Arsenazo Reagent…Alfa Wassermann Diagnostics Technologies, LLC2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K113374, 1993–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CIX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CIX device

  1. #1 K251157 Core Metabolicscore 11.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K931786Ace Clinical Chemistry System
Summary page 2
…Manufacturer. for analyzer/reagent system predicate: Devices: Alfa Wassermann ACE plus ISE/Clinica] Chemistry System ____________ACE Reagents (K93 1786) Device In the ACE Albumin Reagent assay, Broincresol green binds specifically to Descriptions: albumin to…
Schiapparelli Biosystems, Inc.1993—

Also cleared against K931786: 21 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131488Ace Albumin Reagent, Ace Total Protein Reagent, Ace Calcium-Arsenazo Reagent and Ace…Alfa Wassermann Diagnostics Technologies, LLC20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K131488 (Alfa Wassermann Diagnostics Technologies, LLC, 2013) has gone furthest, with 0 descendants of its own.
  • 21 other devices also cite its predicate K931786.

How does its category compare?

All CIX devices

CIX Bromcresol Green Dye-Binding, Albumin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · CIX

2in 2021

2007: 12008: 12009: 12011: 32012: 12013: 12018: 12019: 12021: 22026 (partial year): 1
2007high 3 (2011) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CIX

168in 2011

2011: 168 days median
2007high 168 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CIX

1in 2020

2008: 12010: 12013: 12019: 12020: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CIX

4in 2025

2007: 12010: 742011: 82012: 22016: 12017: 62018: 22020: 12021: 32022: 12023: 42024: 32025: 4
2007high 74 (2010) · low 0 (2008)2025

MAUDE reports naming product code CIX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
20081—10
20091—00
20100—174
2011316808
20121—02
20131—10
20140—00
20150—00
20160—01
20170—06
20181—02
20191—10
20200—11
20212—03
20220—01
20230—04
20240—03
20250—04
20261—0—

What is it indicated for?

The ACE Albumin Reagent is intended for the quantitative determination of albumin concentration in serum using the ACE Axcel Clinical Chemistry System. Albumin measurements are used in the diagnosis and treatment of numerous diseases involving primarily the liver or kidneys. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only. The ACE Total Protein Reagent is intended for the…

Read the full statement (268 words)

The ACE Albumin Reagent is intended for the quantitative determination of albumin concentration in serum using the ACE Axcel Clinical Chemistry System. Albumin measurements are used in the diagnosis and treatment of numerous diseases involving primarily the liver or kidneys. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

The ACE Total Protein Reagent is intended for the quantitative determination of total protein concentration in serum using the ACE Axcel Clinical Chemistry System. Total protein measurements are used in the diagnosis and treatment of a variety of diseases involving the liver, kidney, or bone marrow as well as other metabolic or nutritional disorders. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

The ACE Calcium-Arsenazo Reagent is intended for the quantitative determination of calcium concentration in serum using the ACE Axcel Clinical Chemistry System. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms). This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

The ACE Inorganic Phosphorus U.V. Reagent is intended for the quantitative determination of inorganic phosphorus concentration in serum using the ACE Axcel Clinical Chemistry System. Measurements of inorganic phosphorus are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases and vitamin D imbalance. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K113374: Ace Albumin Reagent Ace Total Protein Reagent Ace Calcium-Arsenazo Reagent Ace Phosphorus U.V. Reagent.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K113374

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026