510(k) · Cleared
ClearedPower Wheelchair
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Suzhou KD Medical Appliance Co., Ltd. · ITI Wheelchair, Powered
Cleared on Apr 6, 2012 as substantially equivalent to K070501 (Shanghai Ruike Sports Goods Co., Ltd., 2007) after a 136-day review. Its family tree reaches back 3 generations to 2003. 71 later devices descend from it.
- Decided
- Apr 6, 2012
- Review
- 136 days
- Class
- Class II
- Product code
- ITI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K023148 (2003). 71 later devices descend from it, 13 citing it directly.
- Root · 3 generations backK023148 Epw Powered Wheelchair, GP-201Emg Technology Co., Ltd. · 2003
- 2 generations backK062888 Middle Wheel Drive Power Chair, CWD01Emg Technology Co., Ltd. · 2006
- 1 generation backK070501 Ruike 3421 Powered WheelchairShanghai Ruike Sports Goods Co., Ltd. · 2007
- This deviceK113463 Power WheelchairSuzhou KD Medical Appliance Co., Ltd. · 2012
- Descendant · cites it directly · 37 of its ownK220747 Power Wheelchair (N5515B)Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2022
- Descendant · 2 generations on · 8 of its ownK231508 Power Wheelchair, W5521Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2023
- Descendant · 2 generations on · 7 of its ownK230964 Power Wheelchair (N5909)Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2023
- Descendant · cites it directly · 7 of its ownK163204 A08 Power wheelchairKunshan Aoshida Electric Technology Co., Ltd. · 2017
- Descendant · 2 generations on · 6 of its ownK240913 Electric Wheelchair (HBLD3-B); Electric Wheelchair (HBLD3-E)Shanghai Hubang Intelligent Rehabilitation Equipment Co.,Ltd · 2024
Showing 5 of 71 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 71 · See all- K220747Power Wheelchair (N5515B)Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2022 · cites it directly37descendants
- K231508Power Wheelchair, W5521Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2023 · 2 generations on8descendants
- K230964Power Wheelchair (N5909)Zhejiang Innuovo Rehabilitation Devices Co.,Ltd · 2023 · 2 generations on7descendants
- K163204A08 Power wheelchairKunshan Aoshida Electric Technology Co., Ltd. · 2017 · cites it directly7descendants
- K240913Electric Wheelchair (HBLD3-B); Electric Wheelchair (HBLD3-E)Shanghai Hubang Intelligent Rehabilitation Equipment Co.,Ltd · 2024 · 2 generations on6descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K023148 | Epw Powered Wheelchair, GP-201 | Emg Technology Co., Ltd. | 2003 | — |
| −2 | K062888 | Middle Wheel Drive Power Chair, CWD01 | Emg Technology Co., Ltd. | 2006 | — |
| −1 | K070501 | Ruike 3421 Powered Wheelchair | Shanghai Ruike Sports Goods Co., Ltd. | 2007 | — |
| 0 (this device) | K113463 | Power Wheelchair | Suzhou KD Medical Appliance Co., Ltd. | 2012 | — |
| +1 | K220747 | Power Wheelchair (N5515B) | Zhejiang Innuovo Rehabilitation Devices Co.,Ltd | 2022 | — |
| +2 | K231508 | Power Wheelchair, W5521 | Zhejiang Innuovo Rehabilitation Devices Co.,Ltd | 2023 | — |
| +2 | K230964 | Power Wheelchair (N5909) | Zhejiang Innuovo Rehabilitation Devices Co.,Ltd | 2023 | — |
| +1 | K163204 | A08 Power wheelchair | Kunshan Aoshida Electric Technology Co., Ltd. | 2017 | — |
| +2 | K240913 | Electric Wheelchair (HBLD3-B); Electric Wheelchair (HBLD3-E) | Shanghai Hubang Intelligent Rehabilitation Equipment Co.,Ltd | 2024 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 6 | 0 |
| 2023 | 4 | 0 |
| 2024 | 24 | 0 |
| 2025 | 20 | 0 |
| 2026 | 14 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ITI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ITI device
- #1 K220747 Power Wheelchair (N5515B)score 40.2 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K070501 | Ruike 3421 Powered WheelchairSummary page 1…ecialty (Panel): Physical Medicine Device Regulation number: 890.3860 Product Code: ITI Classification: Class 11 Predicate devices Ruike 3421 (K070501) / Shanghai Ruike Sports Goods CO., LTD Intend use of device The device is a motor driven, indoor and outdoor transport… | 2007 |
What descends from it? (71)
See all 7113 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K220747 | Power Wheelchair (N5515B) | 2022 | 37 |
| K163204 | A08 Power wheelchair | 2017 | 7 |
| K232193 | Electrically Power Wheelchairs (Models:YLB-W-0812-A01, YLB-W-0812-A02, YLB-W-0812-A03) | 2023 | 5 |
| K212092 | Portable Folding Electric Wheelchair (Model: DC01) | 2022 | 5 |
| K202482 | Y207 Electric Wheelchair | 2021 | 5 |
| K250158 | Electric Wheelchair (ZH-W001,ZH-W002 ,ZH-W003) | 2025 | 2 |
| K262241 | Electric Wheelchair (0080) | 2026 | 0 |
| K260373 | Electric Wheelchair (DF506) | 2026 | 0 |
| K252829 | Powered Wheelchair (PL001-9001) | 2025 | 0 |
| K251248 | Electric Wheelchair (QDWP-A01,QDWP-B02) | 2025 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 3.7 years on median.
- None of the 3 ancestors has a recall.
- Of its descendants, K220747 (Zhejiang Innuovo Rehabilitation Devices Co.,Ltd, 2022) has gone furthest, with 37 descendants of its own.
- 1 other device also cites its predicate K070501.
How does its category compare?
All ITI devicesITI Wheelchair, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · ITI
29in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ITI
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · ITI
13so far in 2026, the most since 2007
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · ITI
647in 2025
MAUDE reports naming product code ITI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 42 | 3 | 123 |
| 2008 | 9 | 49 | 3 | 133 |
| 2009 | 7 | 63 | 1 | 183 |
| 2010 | 6 | 46 | 2 | 157 |
| 2011 | 4 | 101 | 0 | 525 |
| 2012 | 6 | 155 | 1 | 2,919 |
| 2013 | 5 | 177 | 0 | 8,741 |
| 2014 | 5 | 213 | 0 | 7,282 |
| 2015 | 10 | 174 | 0 | 4,685 |
| 2016 | 6 | 173 | 1 | 1,575 |
| 2017 | 4 | 159 | 2 | 301 |
| 2018 | 4 | 117 | 0 | 273 |
| 2019 | 3 | 244 | 0 | 264 |
| 2020 | 6 | 278 | 0 | 205 |
| 2021 | 13 | 209 | 3 | 166 |
| 2022 | 16 | 96 | 0 | 135 |
| 2023 | 8 | 128 | 0 | 223 |
| 2024 | 38 | 125 | 1 | 146 |
| 2025 | 29 | 90 | 3 (2) | 647 |
| 2026 | 36 | 108 | 13 | — |
What is it indicated for?
The device is a motor driven. indoor and outdoor transportation vehicle with the intended use to Provide mobility to a disabled or elderly person limited to a seated position.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K113463 · printed Nov 6, 2026
Cite this page
510(k) Report. “K113463: Power Wheelchair.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113463
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026