Lima Corporate S.P.A. · PHX Shoulder Prosthesis, Reverse Configuration
Cleared on Dec 20, 2011 as substantially equivalent to K110598 (Lima Corporate S.P.A., 2011) after a 21-day review. Its family tree reaches back 10 generations to 1991. 10 later devices descend from it.
- Decided
- Dec 20, 2011
- Review
- 21 days
- Class
- Class II
- Product code
- PHX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 10 generations to K911686 (1991). 31 ancestors in all, the oldest K800494 (1980). 10 later devices descend from it, 1 citing it directly.
- Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 6 generations between
- 3 generations backK073676 Depuy Delta Xtend Reverse Shoulder High Mobility CupDePuy Orthopaedics, Inc. · 2008
- 2 generations backK091751 Depuy Delta Xtend Reverse Shoulder XLK CupDePuy Orthopaedics, Inc. · 2009
- 1 generation backK110598 SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011 · Recalled
- This deviceK113523 Limacorporate SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011
- Descendant · cites it directly · 9 of its ownK130050 Titan Reverse Shoulder SystemAscension Orthopedic · 2013
- Descendant · 2 generations on · 8 of its ownK161189 Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2016
- Descendant · 3 generations on · 4 of its ownK190588 Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2019
- Descendant · 3 generations on · 3 of its ownK173717 Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2018
- Descendant · 4 generations on · 2 of its ownK181999 Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2018
Show all 10 generations
- Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 9 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
- 8 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
- 7 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
- 6 generations backK062116 Delta Cta Reverse Shoulder System Humeral HeadsDePuy Orthopaedics, Inc. · 2006
- 5 generations backK062250 Delta Xtend Reverse Shoulder SystemDePuy Orthopaedics, Inc. · 2007 · Recalled
- 4 generations backK071379 Delta Xtend Reverse Shoulder Modular StemDePuy Orthopaedics, Inc. · 2007
- 3 generations backK073676 Depuy Delta Xtend Reverse Shoulder High Mobility CupDePuy Orthopaedics, Inc. · 2008
- 2 generations backK091751 Depuy Delta Xtend Reverse Shoulder XLK CupDePuy Orthopaedics, Inc. · 2009
- 1 generation backK110598 SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011 · Recalled
- This deviceK113523 Limacorporate SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011
Showing 5 of 10 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 10 · See all- K130050Titan Reverse Shoulder SystemAscension Orthopedic · 2013 · cites it directly9descendants
- K161189Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2016 · 2 generations on8descendants
- K190588Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2019 · 3 generations on4descendants
- K173717Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2018 · 3 generations on3descendants
- K181999Integra TITAN Reverse Shoulder SystemIntegra LifeSciences Corporation · 2018 · 4 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K911686 | Global Total Shoulder, Uncement Humeral Hemi-Shoul | Depuy, Inc. | 1991 | — |
| −9 | K984541 | Global FX Humeral Stem, Global Advantage Humeral Head | DePuy Orthopaedics, Inc. | 1999 | — |
| −8 | K992065 | Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage… | DePuy Orthopaedics, Inc. | 1999 | — |
| −7 | K021478 | Delta Shoulder | Depuy, Inc. | 2003 | — |
| −6 | K062116 | Delta Cta Reverse Shoulder System Humeral Heads | DePuy Orthopaedics, Inc. | 2006 | — |
| −5 | K062250 | Delta Xtend Reverse Shoulder System | DePuy Orthopaedics, Inc. | 2007 | 8 |
| −4 | K071379 | Delta Xtend Reverse Shoulder Modular Stem | DePuy Orthopaedics, Inc. | 2007 | — |
| −3 | K073676 | Depuy Delta Xtend Reverse Shoulder High Mobility Cup | DePuy Orthopaedics, Inc. | 2008 | — |
| −2 | K091751 | Depuy Delta Xtend Reverse Shoulder XLK Cup | DePuy Orthopaedics, Inc. | 2009 | — |
| −1 | K110598 | SMR Reverse Shoulder System | Lima Corporate S.P.A. | 2011 | 1 |
| 0 (this device) | K113523 | Limacorporate SMR Reverse Shoulder System | Lima Corporate S.P.A. | 2011 | — |
| +1 | K130050 | Titan Reverse Shoulder System | Ascension Orthopedic | 2013 | — |
| +2 | K161189 | Integra TITAN Reverse Shoulder System | Integra LifeSciences Corporation | 2016 | — |
| +3 | K190588 | Integra TITAN Reverse Shoulder System | Integra LifeSciences Corporation | 2019 | — |
| +3 | K173717 | Integra TITAN Reverse Shoulder System | Integra LifeSciences Corporation | 2018 | — |
| +4 | K181999 | Integra TITAN Reverse Shoulder System | Integra LifeSciences Corporation | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 2 | 0 |
| 1992 | 1 | 0 |
| 1995 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 4 | 0 |
| 2000 | 1 | 0 |
| 2001 | 3 | 0 |
| 2003 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 1 | 0 |
| 2024 | 2 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PHX device
- #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K110598 | SMR Reverse Shoulder SystemSummary page 4…er | KWS Shoulder joint metal/polymer semi-constrained System cemented prosthesis per 21 CFR 888.3660 Description: The SMR Reverse Shoulder System (cleared via 510(k): K110598) consists of a humeral stem, a reverse humeral body, a reverse liner, a metal-back glenoid, a glenosphere and a connector with sc… | 2011 |
What descends from it? (10)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K130050 | Titan Reverse Shoulder System | 2013 | 9 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 1.5 years on median.
- 10 of the 31 ancestors have a recall of any class.
- Of its descendants, K130050 (Ascension Orthopedic, 2013) has gone furthest, with 9 descendants of its own.
- 11 other devices also cite its predicate K110598.
How does its category compare?
All PHX devicesPHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · PHX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PHX
72in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PHX
3in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PHX
2,848in 2025
MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 97 | 0 | 0 |
| 2008 | 6 | 79 | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 8 | 124 | 0 | 0 |
| 2011 | 12 | 94 | 0 | 0 |
| 2012 | 12 | 114 | 0 | 0 |
| 2013 | 8 | 143 | 0 | 0 |
| 2014 | 12 | 110 | 0 | 0 |
| 2015 | 4 | 206 | 2 | 14 |
| 2016 | 4 | 132 | 0 | 5 |
| 2017 | 11 | 141 | 0 | 25 |
| 2018 | 14 | 127 | 1 | 323 |
| 2019 | 9 | 144 | 3 | 504 |
| 2020 | 13 | 143 | 3 | 986 |
| 2021 | 21 | 143 | 8 | 1,404 |
| 2022 | 9 | 198 | 0 | 1,342 |
| 2023 | 9 | 154 | 7 | 1,401 |
| 2024 | 9 | 139 | 1 | 2,142 |
| 2025 | 9 | 72 | 3 | 2,848 |
| 2026 | 18 | 130 | 7 | — |
What is it indicated for?
The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy. The patient's joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device. The SMR Reverse Shoulder System humeral bodies, cemented non-finned humeral stems and cemented revision stems are intended…
Read the full statement (112 words)
The SMR Reverse Shoulder System is indicated for primary, fracture or revision total shoulder replacement in a grossly rotator cuff deficient joint with severe arthropathy.
The patient's joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device.
The SMR Reverse Shoulder System humeral bodies, cemented non-finned humeral stems and cemented revision stems are intended for cemented use. The SMR Reverse Shoulder System humeral bodies, finned humeral stems and uncemented revision stems are intended for cementless use. The SMR Reverse Shoulder System metal-backed glenoids and glenospheres are intended for uncemented press-fit use only with the addition of screws for fixation.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K113523 · printed Nov 6, 2026
Cite this page
510(k) Report. “K113523: Limacorporate SMR Reverse Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113523
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026