Medical Compression Systems (Dbn), Ltd. · JOW Sleeve, Limb, Compressible
Cleared on Jan 31, 2012 as substantially equivalent to K023573 (Medical Compression Systems (Dbn), Ltd., 2002) and 1 other predicate after a 63-day review. Its family tree reaches back 4 generations to 1995. 8 later devices descend from it.
- Decided
- Jan 31, 2012
- Review
- 63 days
- Class
- Class II
- Product code
- JOW
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K944567 (1995). 10 ancestors in all, the oldest K915092 (1992). 8 later devices descend from it, 1 citing it directly.
- Root · 4 generations backK944567 Cowboy XKinetic Concepts, Inc. · 1995 · Recalled
- 3 generations backK981311 Cowboy XVKci New Technologies, Inc. · 1999
- 2 generations backK993758 Proair 3000 Compression SystemMedical Compression Systems (Dbn), Ltd. · 2000
- 1 generation backK060146 Activecare ++ SystemMedical Compression Systems (Dbn), Ltd. · 2006 · Recalled
- This deviceK113525 Activecare DVT Activecare+SFTMedical Compression Systems (Dbn), Ltd. · 2012
- Descendant · cites it directly · 7 of its ownK140755 Activecare DVT, Activecare+SFT, and Activecare+DTX SystemsMedical Compression Systems (Dbn), Ltd. · 2014
- Descendant · 2 generations on · 2 of its ownK162481 RF1400 Active Compression WrapRecovery Force, LLC · 2017
- Descendant · 2 generations on · 2 of its ownK142728 ActiveCare+SFT; ActiveCare+SFT HomeCare…Medical Compressions System (Dbn), Ltd. · 2014
- Descendant · 3 generations on · 1 of its ownK232300 ElastiMed SACSElastimed, Ltd. · 2023
- Descendant · 3 generations on · 1 of its ownK151377 ActiveCare+SFT;ActiveCare+SFT HomeCare…Medical Compression System (Dbn), Ltd. · 2015
Showing 5 of 8 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 8 · See all- K140755Activecare DVT, Activecare+SFT, and Activecare+DTX SystemsMedical Compression Systems (Dbn), Ltd. · 2014 · cites it directly7descendants
- K162481RF1400 Active Compression WrapRecovery Force, LLC · 2017 · 2 generations on2descendants
- K142728ActiveCare+SFT; ActiveCare+SFT HomeCare (ActiveCare+SFT-sub-category), ActiveCare+DTx…Medical Compressions System (Dbn), Ltd. · 2014 · 2 generations on2descendants
- K232300ElastiMed SACSElastimed, Ltd. · 2023 · 3 generations on1descendant
- K151377ActiveCare+SFT;ActiveCare+SFT HomeCare, ActiveCare+DTx;ActiveCare+DTx HomeCareMedical Compression System (Dbn), Ltd. · 2015 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K944567 | Cowboy X | Kinetic Concepts, Inc. | 1995 | 1 |
| −3 | K981311 | Cowboy XV | Kci New Technologies, Inc. | 1999 | — |
| −2 | K993758 | Proair 3000 Compression System | Medical Compression Systems (Dbn), Ltd. | 2000 | — |
| −1 | K060146 | Activecare ++ System | Medical Compression Systems (Dbn), Ltd. | 2006 | 1 |
| 0 (this device) | K113525 | Activecare DVT Activecare+SFT | Medical Compression Systems (Dbn), Ltd. | 2012 | — |
| +1 | K140755 | Activecare DVT, Activecare+SFT, and Activecare+DTX Systems | Medical Compression Systems (Dbn), Ltd. | 2014 | — |
| +2 | K162481 | RF1400 Active Compression Wrap | Recovery Force, LLC | 2017 | — |
| +2 | K142728 | ActiveCare+SFT; ActiveCare+SFT HomeCare (ActiveCare+SFT-sub-category)… | Medical Compressions System (Dbn), Ltd. | 2014 | — |
| +3 | K232300 | ElastiMed SACS | Elastimed, Ltd. | 2023 | — |
| +3 | K151377 | ActiveCare+SFT;ActiveCare+SFT HomeCare, ActiveCare+DTx;ActiveCare+DTx HomeCare | Medical Compression System (Dbn), Ltd. | 2015 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 2 | 0 |
| 1995 | 1 | 0 |
| 2000 | 1 | 0 |
| 2002 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JOW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JOW device
- #1 K253555 Flexitouch® Plus Advanced Pneumatic…score 14.8 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023573 | Wizair Compression SystemSummary page 1…1;Product Code: JOW Regulation No. 870.5800 Panel: Cardiovascular Devices Predicate Devices Medical Compression Systems (DEN) Ltd. ActiveCare DVT (K023573) Medical Compression Systems (DBN) Ltd. ActiveCare+SFT (K060146) Purpose of 510(k) Notice This 51 0(k) was submitted in o… | 2002 |
| * | K060146 | Activecare ++ SystemSummary page 1…vascular Devices Predicate Devices Medical Compression Systems (DEN) Ltd. ActiveCare DVT (K023573) Medical Compression Systems (DBN) Ltd. ActiveCare+SFT (K060146) Purpose of 510(k) Notice This 51 0(k) was submitted in order to clear minor modifications to the ActiveCare DVT System and the… | 2006 |
What descends from it? (8)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K140755 | Activecare DVT, Activecare+SFT, and Activecare+DTX Systems | 2014 | 7 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 5.8 years on median.
- 3 of the 10 ancestors have a recall of any class.
- Of its descendants, K140755 (Medical Compression Systems (Dbn), Ltd., 2014) has gone furthest, with 7 descendants of its own.
- 4 other devices also cite its predicate K023573.
How does its category compare?
All JOW devicesJOW Sleeve, Limb, Compressible: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · JOW
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JOW
168in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JOW
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JOW
24in 2025
MAUDE reports naming product code JOW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 66 | 0 | 12 |
| 2008 | 4 | 112 | 7 | 36 |
| 2009 | 3 | 84 | 0 | 45 |
| 2010 | 18 | 71 | 2 | 66 |
| 2011 | 11 | 104 | 3 | 50 |
| 2012 | 13 | 63 | 2 | 100 |
| 2013 | 17 | 94 | 0 | 169 |
| 2014 | 16 | 91 | 0 | 93 |
| 2015 | 10 | 160 | 0 | 137 |
| 2016 | 9 | 121 | 0 | 150 |
| 2017 | 9 | 116 | 1 | 149 |
| 2018 | 11 | 136 | 0 | 114 |
| 2019 | 11 | 88 | 1 | 102 |
| 2020 | 14 | 158 | 0 | 50 |
| 2021 | 16 | 132 | 0 | 34 |
| 2022 | 7 | 80 | 0 | 27 |
| 2023 | 6 | 160 | 0 | 57 |
| 2024 | 8 | 197 | 0 | 30 |
| 2025 | 7 | 168 | 0 | 24 |
| 2026 | 6 | 252 | 0 | — |
What is it indicated for?
The ActiveCare DVT and ActiveCare+SFT Systems are prescription devices that induce Continuous Enhanced Circulation Therapy of the lower limbs.
The Systems are intended for use in:
* Preventing Deep Vein Thrombosis (DVT).
* Enhancing blood circulation.
* Diminishing post-operative pain and swelling.
* Reducing wound-healing time.
* Treatment and assistance in healing: stasis dermatitis; venous stasis ulcers; arterial and diabetic leg ulcers.
* Treatment of chronic venous insufficiency.
* Reducing edema.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K113525 · printed Nov 6, 2026
Cite this page
510(k) Report. “K113525: Activecare DVT Activecare+SFT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113525
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026