# K113572: Ligasure Curved, Small Jaw, Open Sealer/Divider

- Pathway: 510(k) (Traditional)
- Applicant: Covidien, Formerly Valleylab, A Division of Tyco H
- Decided: Sep 5, 2012 after 278 days
- Product code: GEI (Electrosurgical, Cutting & Coagulation & Accessories)
- Device class: 2
- Regulation: 21 CFR 878.4400
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 4 generations back to K932293 (1994). 11 ancestors in all.
62 later devices descend from it; 9 cite it directly.
0 of 74 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K102470: Lugasure Curved, Small Jaw, Open Sealer/Divider, Covidien, Formerly Valleylab, (2011) Summary page 1.
- K010010: Valleylab Ligasure Precise Instrument Vessel Sealing System-Model # LS1200 & Sligaure Generator, Valleylab, Inc. (2001) Summary page 1.

## Most influential descendants
- K133338: Ligasure 5 MM Maryland Jaw Sealer/Divider One-Step Sealing (LF 17XX) (2013), 43 descendants of its own
- K141153: Ligasure; Curved Small Jaw Sealer/Divider, 5MM Blunt Tip Sealer/Divider, Maryland Jaw One Step Stealer/Dividers, Curved (2014), 40 descendants of its own
- K152286: LigaSure Curved, Small Jaw, Open Sealer/Divider (2015), 14 descendants of its own
- K170869: LigaSure Maryland Jaw Sealer/Divider One-step Sealing, Nano-coated (2017), 11 descendants of its own
- K132703: Thunderbeat (2014), 9 descendants of its own

## Indications for use
The LigaSure Curved, Small Jaw, Open Sealer / Divider is a bipolar electrosurgical instrument intended to be used with the ForceTriad energy platform. The instrument is indicated for use in open general surgical procedures where ligation and division of vessels (up to 7 mm in diameter), tissue bundles, and lymphatics is performed, such as urologic, thoracic, plastic, and reconstructive; and including such procedures as bowel resections, gall bladder procedures, Nissen fundoplication, adhesiolysis, etc. The device is also indicated for open ENT procedures in adults (thyroidectomy, radical neck dissection, parotidectomy, and tonsillectomy) for ligation and division of vessels, lymphatics and tissue bundles 2-3 mm away from unintended thermally sensitive structures such as nerves and parathyroid glands. The LigaSure system has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures. Do not use the LigaSure system for these procedures.