510(k) Report

510(k) · Cleared

Recalled · Class II · 2020

Comprehensive Reverse Shoulder-Mini Baseplate

K120121510(k) SpecialCleared Feb 16, 201230-day reviewClass II21 CFR 888.3660Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomet, Inc. · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on Feb 16, 2012 as substantially equivalent to K080642 (Biomet, Inc., 2008) after a 30-day review. Its family tree reaches back 11 generations to 1991. 1 of the 122 devices in its family, counting itself, has a Class I recall. 69 later devices descend from it. It has been recalled 4 times.

Decided
Feb 16, 2012
Review
30 days
Class
Class II
Product code
PHX
Recalls
4
Predicates
1

Its longest line of descent runs back 11 generations to K911686 (1991). 52 ancestors in all, the oldest K790987 (1979). 69 later devices descend from it, 9 citing it directly. 1 of the 122 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2006: 2 other ancestors2005: 6 other ancestors2004: 1 other ancestor2003: 2 other ancestors1999: 4 other ancestors2001: 3 other ancestors2000: 2 other ancestors1998: 3 other ancestors1995: 2 other ancestors1994: 1 other ancestor1992: 2 other ancestors1987: 2 other ancestors1996: 4 other ancestors1993: 1 other ancestor1989: 1 other ancestor1986: 1 other ancestor1980: 2 other ancestors1979: 1 other ancestor2013: 2 descendants cleared2023: 9 descendants cleared2022: 8 descendants cleared2018: 2 descendants cleared2026: 13 descendants cleared2021: 7 descendants cleared2020: 3 descendants cleared2016: 1 descendant cleared2014: 1 descendant cleared2019: 3 descendants cleared2024: 8 descendants cleared2025: 11 descendants cleared2015: 1 descendant clearedK911686 · Global Total Shoulder, Uncement Humeral Hemi-Shoul · Depuy, Inc. · 1991×2: 2 generations cleared close together, K984541 (1999), K992065 (1999) ×3: 3 generations cleared close together, K021478 (2003), K030941 (2004), K041873 (2004) ×2: 2 generations cleared close together, K052906 (2005), K060704 (2006) K063569 · Equinoxe Reverse Shoulder System · Exactech, Inc. · 2007 · recalled×2: 2 generations cleared close together, K073688 (2008), K080642 (2008) 19801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 4 other ancestors3 generations back: 9 other ancestors4 generations back: 16 other ancestors5 generations back: 12 other ancestors 1 generation forward: 9 descendants2 generations forward: 18 descendants3 generations forward: 17 descendants4 generations forward: 8 descendants5 generations forward: 7 descendants6 generations forward: 8 descendants7 generations forward: 2 descendants K080642 · Comprehensive Reverse Shoulder · Biomet, Inc. · 2008 · Class I recallK073688 · Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and Locking Screw · Exactech, Inc. · 2008 · recalledK063569 · Equinoxe Reverse Shoulder System · Exactech, Inc. · 2007 · recalledK060704 · Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MM · Zimmer, Inc. · 2006 · recalledK052906 · Zimmer Trabecular Metal Reverse Shoulder System · Zimmer, Inc. · 2005 · recalledK041873 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2004K030941 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2004K021478 · Delta Shoulder · Depuy, Inc. · 2003K992065 · Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage Eccentric Head · DePuy Orthopaedics, Inc. · 1999K984541 · Global FX Humeral Stem, Global Advantage Humeral Head · DePuy Orthopaedics, Inc. · 1999K911686 · Global Total Shoulder, Uncement Humeral Hemi-Shoul · Depuy, Inc. · 1991−10−50+5
  1. Root · 11 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 7 generations between
  3. 3 generations backK063569 Equinoxe Reverse Shoulder SystemExactech, Inc. · 2007 · Recalled
  4. 2 generations backK073688 Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and…Exactech, Inc. · 2008 · Recalled
  5. 1 generation backK080642 Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · Recalled (Class I)
  6. This deviceK120121 Comprehensive Reverse Shoulder-Mini BaseplateBiomet, Inc. · 2012
  7. Descendant · cites it directly · 60 of its ownK131353 Comprehensive Reverse Shoulder - Titanium GlenosphereBiomet Manufacturing Corp · 2013
  8. Descendant · cites it directly · 22 of its ownK152754 Comprehensive Vault Reconstruction System (VRS)Biomet Manufacturing Corp · 2016 · Recalled
  9. Descendant · 2 generations on · 21 of its ownK140478 Aequalis Reversed Shoulder ProsthesisTornier S.A.S. · 2014
  10. Descendant · cites it directly · 20 of its ownK193373 Comprehensive® Reverse ShoulderBiomet, Inc. · 2020 · Recalled
  11. Descendant · cites it directly · 20 of its ownK172502 Comprehensive Augmented Glenoid Components, Comprehensive Standard…Biomet Manufacturing Corp · 2018 · Recalled
Show all 11 generations
  1. Root · 11 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 10 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
  3. 9 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
  4. 8 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
  5. 7 generations backK030941 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  6. 6 generations backK041873 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  7. 5 generations backK052906 Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc. · 2005 · Recalled
  8. 4 generations backK060704 Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc. · 2006 · Recalled
  9. 3 generations backK063569 Equinoxe Reverse Shoulder SystemExactech, Inc. · 2007 · Recalled
  10. 2 generations backK073688 Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and…Exactech, Inc. · 2008 · Recalled
  11. 1 generation backK080642 Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · Recalled (Class I)
  12. This deviceK120121 Comprehensive Reverse Shoulder-Mini BaseplateBiomet, Inc. · 2012

Showing 5 of 69 descendants. See all descendants

Descendants cleared per year

2013: 22014: 12015: 12016: 12018: 22019: 32020: 32021: 72022: 82023: 92024: 82025: 112026: 13
2013high 13 (2026) · low 0 (2017)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 69 · See all
  • K131353Comprehensive Reverse Shoulder - Titanium GlenosphereBiomet Manufacturing Corp · 2013 · cites it directly60descendants
  • K152754Comprehensive Vault Reconstruction System (VRS)Biomet Manufacturing Corp · 2016 · cites it directly22descendants
  • K140478Aequalis Reversed Shoulder ProsthesisTornier S.A.S. · 2014 · 2 generations on21descendants
  • K193373Comprehensive® Reverse ShoulderBiomet, Inc. · 2020 · cites it directly20descendants
  • K172502Comprehensive Augmented Glenoid Components, Comprehensive Standard Baseplate…Biomet Manufacturing Corp · 2018 · cites it directly20descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K911686Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc.1991—
−10K984541Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc.1999—
−9K992065Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage…DePuy Orthopaedics, Inc.1999—
−8K021478Delta ShoulderDepuy, Inc.2003—
−7K030941Aequalis Reversed Shoulder ProsthesisTornier2004—
−6K041873Aequalis Reversed Shoulder ProsthesisTornier2004—
−5K052906Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc.200512
−4K060704Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc.200610
−3K063569Equinoxe Reverse Shoulder SystemExactech, Inc.200713
−2K073688Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and Locking ScrewExactech, Inc.20081
−1K080642Comprehensive Reverse ShoulderBiomet, Inc.2008Class I
0 (this device)K120121Comprehensive Reverse Shoulder-Mini BaseplateBiomet, Inc.2012—
+1K131353Comprehensive Reverse Shoulder - Titanium GlenosphereBiomet Manufacturing Corp2013—
+1K152754Comprehensive Vault Reconstruction System (VRS)Biomet Manufacturing Corp20161
+2K140478Aequalis Reversed Shoulder ProsthesisTornier S.A.S.2014—
+1K193373Comprehensive® Reverse ShoulderBiomet, Inc.20202
+1K172502Comprehensive Augmented Glenoid Components, Comprehensive Standard Baseplate…Biomet Manufacturing Corp20181

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198020
198610
198720
198910
199220
199310
199410
199520
199640
199830
199940
200020
200130
200320
200410
200560
200620
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201320
201410
201510
201610
201820
201930
202030
202170
202280
202390
202480
2025110
2026130
FIG. 1 — Lineage of K120121, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080642Comprehensive Reverse Shoulder
Summary page 4
…ssification panel Orthopedics Regulation 21 CFR 888.3660 Product Code(s) KWS Legally marketed device(s) | Comprehensive® Reverse Shoulder to which equivalence is 510(k) K080642 daimed Reason for 51.0(k) Line Extension submission . Device description The Comprehensive® Reverse Shoulder is intended for t…
Biomet, Inc.2008Class I

Also cleared against K080642: 23 other devices →

What descends from it? (69)

See all 69

9 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131353Comprehensive Reverse Shoulder - Titanium GlenosphereBiomet Manufacturing Corp201360
K152754Comprehensive Vault Reconstruction System (VRS)Biomet Manufacturing Corp201622
K193373Comprehensive® Reverse ShoulderBiomet, Inc.202020
K172502Comprehensive Augmented Glenoid Components, Comprehensive Standard Baseplate…Biomet Manufacturing Corp201820
K130390Comprehensive Convertible GlenoidBiomet Manufacturing, Inc.20138
K213459Glenoid Reconstruction SystemMedacta International S.A.20225
K210533Inset Reverse Total Shoulder SystemShoulder Innovations, Inc.20213
K252404Comprehensive Reverse Shoulder - HA Glenosphere BaseplatesBiomet Orthopedics20260
K231445LINK Embrace Shoulder System - Reverse ConfigurationWaldemar Link GmbH & Co. KG20230

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 2, 2020Class IIZ-0093-2021Packaging process controlProduct potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates…
Feb 25, 2020Class IIZ-1615-2020Packaging process controlPackage is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters.
Dec 21, 2018Class IIZ-0972-2019Packaging process controlThe product was potentially being packaged without a taper adapter.
Jan 7, 2015Class IIZ-1208-2015Process controlThe taper adaptor is missing from the packaging, which may result in a delay in surgery greater than 30 minutes.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K080642Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 9 months on median.
  • 18 of the 52 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K131353 (Biomet Manufacturing Corp, 2013) has gone furthest, with 60 descendants of its own.
  • 23 other devices also cite its predicate K080642.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

The Comprehensive® Reverse Shoulder is indicated for use in patients whose shoulder joint has a grossly deficient rotator cuff with severe arthropathy and/or previously failed shoulder joint replacement with a grossly deficient rotator cuff. The patient must be anatomically and structurally suited to receive the implants and a functional deltoid muscle is necessary. The Comprehensive®Reverse Shoulder is indicated for primary, fracture, or revision total…

Read the full statement (153 words)

The Comprehensive® Reverse Shoulder is indicated for use in patients whose shoulder joint has a grossly deficient rotator cuff with severe arthropathy and/or previously failed shoulder joint replacement with a grossly deficient rotator cuff. The patient must be anatomically and structurally suited to receive the implants and a functional deltoid muscle is necessary.

The Comprehensive®Reverse Shoulder is indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency.

Glenoid components with Hydroxyapatite (HA) coating applied over the porous coating are indicated only for uncemented biological fixation applications. The Glenoid Baseplate components are intended for cementless application with the addition of screw fixation,

Interlok® finish humeral stems are intended for cemented use and the MacroBond® coated humeral stems are intended for press-fit or cemented applications. Humeral components with porous coated surface coating are indicated for either cemented or uncemented biological fixation applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K120121: Comprehensive Reverse Shoulder-Mini Baseplate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K120121

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026