510(k) Report

510(k) · Cleared

Cleared

Titanium Fletcher-Style Applicator Set-Defined Geometry

K120731510(k) TraditionalCleared Jun 6, 201289-day reviewClass II21 CFR 892.5700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Varian Medical Systems, Inc. · JAQ System, Applicator, Radionuclide, Remote-Controlled

Cleared on Jun 6, 2012 as substantially equivalent to K980590 (Varian Medical Systems, Inc., 1998) after an 89-day review. Its family tree reaches back 2 generations to 1987. 3 later devices descend from it.

Decided
Jun 6, 2012
Review
89 days
Class
Class II
Product code
JAQ
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K871217 (1987). 3 later devices descend from it, 1 citing it directly.

  1. Root · 2 generations backK871217 Henschke Afterloading ApplicatorMick Radio-Nuclear Instruments, Inc. · 1987
  2. 1 generation backK980590 Varisource Henschke Type Gyn Applicator for Varian Varisource Remote…Varian Medical Systems, Inc. · 1998
  3. This deviceK120731 Titanium Fletcher-Style Applicator Set-Defined GeometryVarian Medical Systems, Inc. · 2012
  4. Descendant · cites it directly · 2 of its ownK241853 Titanium Fletcher-Style Applicator Set Defined Geometry; Smit…Varian Medical Systems, Inc. · 2024
  5. Descendant · 2 generations on · 0 of its ownK250299 CT/ MR Tandem and Ovoid SetVarian Medical Systems, Inc. · 2025
  6. Descendant · 2 generations on · 0 of its ownK243939 Titanium Flexible Geometry FSD Applicator Set (GM11013400)Varian Medical Systems, Inc. · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K241853Titanium Fletcher-Style Applicator Set Defined Geometry; Smit Cervical SleeveVarian Medical Systems, Inc. · 2024 · cites it directly2descendants
  • K250299CT/ MR Tandem and Ovoid SetVarian Medical Systems, Inc. · 2025 · 2 generations on0descendants
  • K243939Titanium Flexible Geometry FSD Applicator Set (GM11013400)Varian Medical Systems, Inc. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K871217Henschke Afterloading ApplicatorMick Radio-Nuclear Instruments, Inc.1987—
−1K980590Varisource Henschke Type Gyn Applicator for Varian Varisource Remote High Dose…Varian Medical Systems, Inc.1998—
0 (this device)K120731Titanium Fletcher-Style Applicator Set-Defined GeometryVarian Medical Systems, Inc.2012—
+1K241853Titanium Fletcher-Style Applicator Set Defined Geometry; Smit Cervical SleeveVarian Medical Systems, Inc.2024—
+2K250299CT/ MR Tandem and Ovoid SetVarian Medical Systems, Inc.2025—
+2K243939Titanium Flexible Geometry FSD Applicator Set (GM11013400)Varian Medical Systems, Inc.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
202520
FIG. 1 — Lineage of K120731, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAQ device

  1. #1 K241853 Titanium Fletcher-Style Applicator Set Defined…score 14.9 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K980590Varisource Henschke Type Gyn Applicator for Varian Varisource Remote High Dose Rate…
Summary page 2
…OFFEAThRE/SPECIFICATION - EW/MODIFIED DEIC Predicate Device Henschke Type GYN Applicator N/A Clearance Number: Set (980590 Compatible Afterloader Variource GammaMed plus…
Varian Medical Systems, Inc.1998—

Also cleared against K980590: 1 other device →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K241853Titanium Fletcher-Style Applicator Set Defined Geometry; Smit Cervical SleeveVarian Medical Systems, Inc.20242

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 2 companies; a new generation was cleared every 13.6 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K241853 (Varian Medical Systems, Inc., 2024) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K980590.

How does its category compare?

All JAQ devices

JAQ System, Applicator, Radionuclide, Remote-Controlled: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · JAQ

6in 2025

2007: 112008: 102009: 102010: 22011: 22012: 72013: 62014: 72015: 112016: 62017: 72018: 72019: 22020: 42022: 12023: 22024: 102025: 62026 (partial year): 2
2007high 11 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAQ

91in 2025

2007: 48 days median2008: 34 days median2009: 27 days median2012: 89 days median2013: 100 days median2014: 116 days median2015: 183 days median2016: 154 days median2017: 229 days median2018: 252 days median2020: 62 days median2024: 126 days median2025: 91 days median
2007high 252 (2018) · low 27 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAQ

1in 2019

2008: 52009: 12010: 22011: 132012: 52013: 12019: 12026 (partial year): 3
2007high 13 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAQ

3in 2025

2007: 132008: 322009: 352010: 362011: 422012: 342013: 432014: 182015: 72016: 32017: 52018: 22019: 82020: 82021: 52022: 52023: 32024: 12025: 3
2007high 43 (2013) · low 1 (2024)2025

MAUDE reports naming product code JAQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071148013
20081034532
20091027135
20102—236
20112—1342
2012789534
20136100143
20147116018
20151118307
2016615403
2017722905
2018725202
20192—18
202046208
20210—05
20221—05
20232—03
20241012601
202569103
20262—3—

What is it indicated for?

The Titanium Fletcher-style Applicator Set with defined geometry was developed for brachytherapy treatment of cancer of the uterus, cervix, endometrium and vagina.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K120731: Titanium Fletcher-Style Applicator Set-Defined Geometry.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K120731

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026