Cianna Medical · PBY Temporary Tissue Marker

Cleared on Feb 4, 2013 as substantially equivalent to K102506 (Cortex Manufacturing, Inc., 2011) and 2 other predicates after a 325-day review. Its family tree reaches back 6 generations to 2003. 15 later devices descend from it.

Decided
Feb 4, 2013
Review
325 days
Class
Class II
Product code
PBY
Recalls
None
Predicates
3

Its longest line of descent runs back 6 generations to K023694 (2003). 20 ancestors in all, the oldest K970817 (1997). 15 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 2 other ancestors2010: 2 other ancestors2008: 1 other ancestor2007: 1 other ancestor2004: 2 other ancestors1997: 1 other ancestor2002: 2 other ancestors2001: 1 other ancestor2000: 2 other ancestors2016: 1 descendant cleared2013: 1 descendant cleared2023: 4 descendants cleared2018: 1 descendant cleared2017: 1 descendant cleared2021: 2 descendants cleared2024: 3 descendants cleared2022: 1 descendant cleared2025: 1 descendant clearedK023694 · Bio-Mark Resorbable Biopsy Site Marker and Bio-Mark Permanent Biopsy Site Marker · Biopsy Sciences, LLC · 2003K051421 · Inter V Brand V-Mark Breast Biopsy Site Marker with Titanium Anchor · Medical Device Technologies, Inc. · 2005K053518 · Interv Brand V-Mark Breast Biopsy Site Marker with Titanium Anchor · Medical Device Technologies, Inc. · 2006K060769 · Hydromark Biopsy Site Marker · Biopsy Sciences, LLC · 2006×2: 2 generations cleared close together, K083006 (2009), K090501 (2009) 1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 4 other ancestors3 generations back: 3 other ancestors4 generations back: 5 other ancestors 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 3 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants6 generations forward: 2 descendants7 generations forward: 1 descendant K090501 · Biopsy Sciences Hydromark Breast Biopsy Site Marker, Models 4005-02-15-T1, 4005-02-15-S1, 4005-03-15-T1, 4005-03-15-S1 · Biopsy Sciences, LLC · 2009K083006 · Biopsy Sciences, Inc., Hydromark Breast Biopsy Site Marker · Biopsy Sciences, LLC · 2009K060769 · Hydromark Biopsy Site Marker · Biopsy Sciences, LLC · 2006K053518 · Interv Brand V-Mark Breast Biopsy Site Marker with Titanium Anchor · Medical Device Technologies, Inc. · 2006K051421 · Inter V Brand V-Mark Breast Biopsy Site Marker with Titanium Anchor · Medical Device Technologies, Inc. · 2005K023694 · Bio-Mark Resorbable Biopsy Site Marker and Bio-Mark Permanent Biopsy Site Marker · Biopsy Sciences, LLC · 2003−50+5
  1. Root · 6 generations backK023694 Bio-Mark Resorbable Biopsy Site Marker and Bio-Mark Permanent Biopsy…Biopsy Sciences, LLC · 2003
  2. 5 generations backK051421 Inter V Brand V-Mark Breast Biopsy Site Marker with Titanium AnchorMedical Device Technologies, Inc. · 2005
  3. 4 generations backK053518 Interv Brand V-Mark Breast Biopsy Site Marker with Titanium AnchorMedical Device Technologies, Inc. · 2006
  4. 3 generations backK060769 Hydromark Biopsy Site MarkerBiopsy Sciences, LLC · 2006
  5. 2 generations backK083006 Biopsy Sciences, Inc., Hydromark Breast Biopsy Site MarkerBiopsy Sciences, LLC · 2009
  6. 1 generation backK090501 Biopsy Sciences Hydromark Breast Biopsy Site Marker, Models…Biopsy Sciences, LLC · 2009
  7. This deviceK120804 Cianna Medical Tissue Marker and Delivery SystemCianna Medical · 2013
  8. Descendant · cites it directly · 13 of its ownK153044 Sentimag System, Sentimark Magnetic Marker SystermEndomagnetics Ltd., · 2016
  9. Descendant · 2 generations on · 12 of its ownK163541 Magseed Magnetic Marker SystemEndomagnetics Ltd., · 2017
  10. Descendant · 3 generations on · 5 of its ownK210600 MOLLIMolli Surgical, Inc. · 2021
  11. Descendant · 4 generations on · 4 of its ownK223107 MOLLI 2Molli Surgical, Inc. · 2023
  12. Descendant · 5 generations on · 3 of its ownK231579 MOLLI 2Molli Surgical, Inc. · 2023 · Recalled

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2013: 12016: 12017: 12018: 12021: 22022: 12023: 42024: 32025: 1
2013high 4 (2023) · low 0 (2014)2026

Most influential descendants

Showing 5 of 15 · See all
  • K153044Sentimag System, Sentimark Magnetic Marker SystermEndomagnetics Ltd., · 2016 · cites it directly13descendants
  • K163541Magseed Magnetic Marker SystemEndomagnetics Ltd., · 2017 · 2 generations on12descendants
  • K210600MOLLIMolli Surgical, Inc. · 2021 · 3 generations on5descendants
  • K223107MOLLI 2Molli Surgical, Inc. · 2023 · 4 generations on4descendants
  • K231579MOLLI 2Molli Surgical, Inc. · 2023 · 5 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K023694Bio-Mark Resorbable Biopsy Site Marker and Bio-Mark Permanent Biopsy Site MarkerBiopsy Sciences, LLC2003—
−5K051421Inter V Brand V-Mark Breast Biopsy Site Marker with Titanium AnchorMedical Device Technologies, Inc.2005—
−4K053518Interv Brand V-Mark Breast Biopsy Site Marker with Titanium AnchorMedical Device Technologies, Inc.2006—
−3K060769Hydromark Biopsy Site MarkerBiopsy Sciences, LLC2006—
−2K083006Biopsy Sciences, Inc., Hydromark Breast Biopsy Site MarkerBiopsy Sciences, LLC2009—
−1K090501Biopsy Sciences Hydromark Breast Biopsy Site Marker, Models 4005-02-15-T1…Biopsy Sciences, LLC2009—
0 (this device)K120804Cianna Medical Tissue Marker and Delivery SystemCianna Medical2013—
+1K153044Sentimag System, Sentimark Magnetic Marker SystermEndomagnetics Ltd.,2016—
+2K163541Magseed Magnetic Marker SystemEndomagnetics Ltd.,2017—
+3K210600MOLLIMolli Surgical, Inc.2021—
+4K223107MOLLI 2Molli Surgical, Inc.2023—
+5K231579MOLLI 2Molli Surgical, Inc.20231

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200020
200110
200220
200420
200710
200810
201020
201120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201610
201710
201810
202120
202210
202340
202430
202510
FIG. 1 — Lineage of K120804, 2003–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PBY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PBY device

  1. #1 K222643 Sirius Pintuition Seed, Sirius Pintuition…score 9.9 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102506Mixed Media Marker
Summary page 1
…Implantable Clip, 21 CFR 878.4300 DEVICE CLASSIFICATION: Class 11 PRODUCT CODE PBY PREDICATE DEVICES: Mixed Media Marker- K102506 TuMark Flex Tissue Marking System- KI 11692 H-ydromark (K09050 1)…
Cortex Manufacturing, Inc.2011—
*K111692Tumark Flex for Mammotome,Tumark Flex for Atec
Summary page 1
…bstantially equivalent in intended use, principal of operation and technological characteristics to the Mixed Media Marker (K 102506), TuMark Flex Tissue Marking System (K 111692), and the H-ydromark (K09050 1). The Cianna Medical Tissue Marker differs from the predicates only in its intended implant durati…
Somatex Medical Technologies GmbH2011—
*K090501Biopsy Sciences Hydromark Breast Biopsy Site Marker, Models 4005-02-15-T1…
Summary page 1
…TE DEVICES: Mixed Media Marker- K102506 TuMark Flex Tissue Marking System- KI 11692 H-ydromark (K09050 1) Substantially Equivalent To: The Cianna Medial Tissue Marker and Delivery System is substantially equivalent in intended use, p…
Biopsy Sciences, LLC2009—

Also cleared against K102506: 3 other devices →

What descends from it? (15)

See all 15

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K153044Sentimag System, Sentimark Magnetic Marker SystermEndomagnetics Ltd.,201613
K132463Cianna Medical Permanent Tissue Marker and Delivery SystemCianna Medical, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
  • 3 of the 20 ancestors have a recall of any class.
  • Of its descendants, K153044 (Endomagnetics Ltd.,, 2016) has gone furthest, with 13 descendants of its own.
  • 3 other devices also cite its predicate K102506.

How does its category compare?

All PBY devices

PBY Temporary Tissue Marker: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · PBY

1in 2023

2013: 12016: 12017: 22021: 12022: 12023: 1
2007high 2 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PBY

Too few PBY 510(k)s in any year since 2007 to give a median.

Recalls per year · PBY

No recall names PBY since 2007.

Adverse event reports per year · PBY

1in 2024

2017: 12019: 12023: 12024: 1
2007high 1 (2017) · low 0 (2007)2025

MAUDE reports naming product code PBY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20131—00
20140—00
20150—00
20161—00
20172—01
20180—00
20190—01
20200—00
20211—00
20221—00
20231—01
20240—01
20250—00
20260—0—

What is it indicated for?

The Cianna Medical Tissue Marker is intended to be placed percutaneously in the breast to temporarily (< 30 days) mark a lumpectomy site intended for surgical removal. Using ultrasound or radiography imaging guidance, the Cianna Tissue Marker is located and surgically removed with the target tissue.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K120804: Cianna Medical Tissue Marker and Delivery System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K120804

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026