# K121018: Bioraptor 2.9, Bioraptor 2.3 PK, Osteoraptor, & Bioraptor Knotless Suture an

- Pathway: 510(k) (Traditional)
- Applicant: Smith & Nephew, Inc.
- Decided: Jun 22, 2012 after 79 days
- Product code: MBI (Fastener, Fixation, Nondegradable, Soft Tissue)
- Device class: 2
- Regulation: 21 CFR 888.3040
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 6 generations back to K961555 (1996). 14 ancestors in all.
29 later devices descend from it; 9 cite it directly.
0 of 44 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K053344: Bioraptor Suture Anchor, Twinfix 2.8 MM Suture Anchor, Twinfix 3.5 MM Suture Anchor, Smith & Nephew, Inc. (2006) Summary page 1.
- K071586: Bioraptor 2.3 PK Suture Anchor, Smith & Nephew Inc., Endoscopy Division (2007) Summary page 1.
- K082215: Osteoraptor Suture Anchor, Smith & Nephew Inc., Endoscopy Division (2008) Summary page 2.
- K093428: Smith & Nephew Knotless Instability Anchor, Smith & Nephew Endoscopy, Inc. (2009) Summary page 2.

## Most influential descendants
- K152566: PEBA Anchor/Suture Combination, 2.0mm Mini-Tac Anchor, Model 10-1629-01, Modification to Twinfix Ti Quick-T, Twinfix FT PK, Twinfix Ultra Ti, Twinfix Ultra PK, Twinfix Ultra HA Suture Anchors, FOOTPRINT Ultra OK Suture Anchors, BIORAPTOR 2.9 Suture Anchor, BIORAPTOR 2.3 PK Suture Anchor, OSTEORAPTOR Suture Anchor, BIORAPTOR Knotless Suture Anchor,  HEALICOIL PK Suture Anchor (formerly Next Generation Fully Threaded Suture Anchor), Bioraptor Curved 2.3 PK Suture Anchors (2015), 6 descendants of its own
- K180951: Responsive Arthroscopy Suture Anchor System (2019), 4 descendants of its own
- K143660: Milagro / Milagro Advance Interference Screw (2015), 4 descendants of its own
- K182507: Tigon Medical Tissue Anchors (2019), 2 descendants of its own
- K181076: Responsive Arthroscopy Wedge Push-In Suture Anchors (2019), 2 descendants of its own

## Indications for use
The Smith & Nephew Suture Anchors are intended for the, reattachment of soft tissue to bone for the following indications: Hip Hip capsule repair Acetabular labrum reattachment/reconstruction Shoulder Capsular stabilization Bankart repair Anterior shoulder instability SLAP lesion repairs Capsular shift or capsulolabral reconstructions Acromioclavicular separation repairs Deltoid repairs Rotator Cuff repairs Biceps Tenodesis Foot and Ankle Hallux valgus repairs Medial or lateral instability repairs/reconstructions Achilles tendon repairs/reconstructions Midfoot reconstructions Metatarsal ligament/tendon repairs/reconstructions Bunionectomy Elbow, Wrist, and Hand Biceps tendon reattachment Ulnar or radial collateral ligament reconstructions Lateral epicondylitis repair Knee Extra-capsular repairs Medial collateral ligament Lateral collateral ligament Posterior oblique ligament Patellar realignment and tendon repairs Vastus medialis obliquous advancement Iliotibial band tenodesis

Source page: https://510kreport.com/device/K121018