510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Powerglide Midline Catheter

K121073510(k) TraditionalCleared Jun 1, 201253-day reviewClass II21 CFR 880.5200Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

C.R. Bard, Inc. · FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

Cleared on Jun 1, 2012 as substantially equivalent to K112347 (Vascular Pathways, Inc., 2011) and 2 other predicates after a 53-day review. Its family tree reaches back 6 generations to 1993. 19 later devices descend from it. It has been recalled once.

Decided
Jun 1, 2012
Review
53 days
Class
Class II
Product code
FOZ
Recalls
1
Predicates
3

Its longest line of descent runs back 6 generations to K932323 (1993). 21 ancestors in all, the oldest K801941 (1980). 19 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 2 other ancestors2008: 2 other ancestors2004: 2 other ancestors2002: 2 other ancestors1999: 3 other ancestors1997: 1 other ancestor1984: 1 other ancestor1980: 1 other ancestor1998: 1 other ancestor2014: 3 descendants cleared2015: 2 descendants cleared2013: 1 descendant cleared2016: 3 descendants cleared2020: 1 descendant cleared2022: 2 descendants cleared2021: 2 descendants cleared2025: 3 descendants cleared2024: 1 descendant cleared2017: 1 descendant clearedK932323 · Percutaneous Introducer · Medamicus, Inc. · 1993K990705 · Medamicus Coaxial Introducer Kit, 10330-XXX, Boston Scientific Coaxial Dilator Set · Medamicus, Inc. · 1999 · recalledK071574 · Stiffer Coaxial Micro-Introducer Kit · Enpath Medical, Inc. · 2007 · recalledK090372 · The Wand Microaccess Safety Introducer · Access Scientific, Inc. · 2009K093022 · The Picc Wand Peelable Safety Introducer · Access Scientific, Inc. · 2010K101422 · The Power Wand Safety Introducer with an Extended Dwell Catheter · Access Scientific, Inc. · 201119801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 5 other ancestors3 generations back: 6 other ancestors4 generations back: 1 other ancestor5 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 4 descendants3 generations forward: 3 descendants4 generations forward: 5 descendants5 generations forward: 2 descendants K101422 · The Power Wand Safety Introducer with an Extended Dwell Catheter · Access Scientific, Inc. · 2011K093022 · The Picc Wand Peelable Safety Introducer · Access Scientific, Inc. · 2010K090372 · The Wand Microaccess Safety Introducer · Access Scientific, Inc. · 2009K071574 · Stiffer Coaxial Micro-Introducer Kit · Enpath Medical, Inc. · 2007 · recalledK990705 · Medamicus Coaxial Introducer Kit, 10330-XXX, Boston Scientific Coaxial Dilator Set · Medamicus, Inc. · 1999 · recalledK932323 · Percutaneous Introducer · Medamicus, Inc. · 1993−50+5
  1. Root · 6 generations backK932323 Percutaneous IntroducerMedamicus, Inc. · 1993
  2. 5 generations backK990705 Medamicus Coaxial Introducer Kit, 10330-XXX, Boston Scientific…Medamicus, Inc. · 1999 · Recalled
  3. 4 generations backK071574 Stiffer Coaxial Micro-Introducer KitEnpath Medical, Inc. · 2007 · Recalled
  4. 3 generations backK090372 The Wand Microaccess Safety IntroducerAccess Scientific, Inc. · 2009
  5. 2 generations backK093022 The Picc Wand Peelable Safety IntroducerAccess Scientific, Inc. · 2010
  6. 1 generation backK101422 The Power Wand Safety Introducer with an Extended Dwell CatheterAccess Scientific, Inc. · 2011
  7. This deviceK121073 Powerglide Midline CatheterC.R. Bard, Inc. · 2012
  8. Descendant · cites it directly · 12 of its ownK133856 Powerglide Midline CatheterC.R. Bard, Inc. · 2014 · Recalled
  9. Descendant · 2 generations on · 5 of its ownK153280 PowerGlide Pro Midline CatheterC.R. Bard, Inc. · 2016
  10. Descendant · 2 generations on · 5 of its ownK150407 BioFlo Midline CatheterNavilyst Medical, Inc. · 2015
  11. Descendant · 3 generations on · 4 of its ownK162377 PowerGlide Pro Midline CatheterC.R. Bard, Inc. · 2016
  12. Descendant · 3 generations on · 3 of its ownK203069 HydroMIDAccess Vascular, Inc. · 2021 · Recalled

Showing 5 of 19 descendants. See all descendants

Descendants cleared per year

2013: 12014: 32015: 22016: 32017: 12020: 12021: 22022: 22024: 12025: 3
2013high 3 (2014) · low 0 (2018)2026

Most influential descendants

Showing 5 of 19 · See all
  • K133856Powerglide Midline CatheterC.R. Bard, Inc. · 2014 · cites it directly12descendants
  • K153280PowerGlide Pro Midline CatheterC.R. Bard, Inc. · 2016 · 2 generations on5descendants
  • K150407BioFlo Midline CatheterNavilyst Medical, Inc. · 2015 · 2 generations on5descendants
  • K162377PowerGlide Pro Midline CatheterC.R. Bard, Inc. · 2016 · 3 generations on4descendants
  • K203069HydroMIDAccess Vascular, Inc. · 2021 · 3 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K932323Percutaneous IntroducerMedamicus, Inc.1993—
−5K990705Medamicus Coaxial Introducer Kit, 10330-XXX, Boston Scientific Coaxial Dilator…Medamicus, Inc.19991
−4K071574Stiffer Coaxial Micro-Introducer KitEnpath Medical, Inc.20072
−3K090372The Wand Microaccess Safety IntroducerAccess Scientific, Inc.2009—
−2K093022The Picc Wand Peelable Safety IntroducerAccess Scientific, Inc.2010—
−1K101422The Power Wand Safety Introducer with an Extended Dwell CatheterAccess Scientific, Inc.2011—
0 (this device)K121073Powerglide Midline CatheterC.R. Bard, Inc.2012—
+1K133856Powerglide Midline CatheterC.R. Bard, Inc.20141
+2K153280PowerGlide Pro Midline CatheterC.R. Bard, Inc.2016—
+2K150407BioFlo Midline CatheterNavilyst Medical, Inc.2015—
+3K162377PowerGlide Pro Midline CatheterC.R. Bard, Inc.2016—
+3K203069HydroMIDAccess Vascular, Inc.20213

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
198410
199710
199810
199930
200220
200420
200820
201120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201430
201520
201630
201710
202010
202120
202220
202410
202530
FIG. 1 — Lineage of K121073, 1993–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FOZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FOZ device

  1. #1 K243403 BD Nexiva™ Closed IV Catheter Systemscore 14.8 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112347Rapid Intravascular Catheter Start System 22 Gauge / 20 Gauge / 18 Gauge
Summary page 1
…Predicate Trade Name: Rapid Intravascular Catheter Start System Classification Name: Intravascular Catheter Premarket Notification: K112347 Manufacturer: Vascular Pathways, Inc. Predicate Trade Name: PowerWand Safety Introdu…
Vascular Pathways, Inc.2011—
*K101422The Power Wand Safety Introducer with an Extended Dwell Catheter
Summary page 1
…Predcatewith an Extended Dwell Catheter Predicae Classification Name: Catheter Introducer Premarket Notification: K101422 Manufacturer: Access Scientific, Inc. Predicate Trade Name: BD Nexiva Closed I…
Access Scientific, Inc.2011—
*K102520BD Nexiva Closed IV Catheter System
Summary page 1
…te Trade Name: BD Nexiva Closed IV Catheter System Classification Name: Intravascular Catheter Premarket Notification: K102520 Manufacturer: Becton Dickinson, Inc.…
Becton Dickinson Infusion Therapy Systems, Inc.2011—

Also cleared against K112347: 2 other devices →

What descends from it? (19)

See all 19

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133856Powerglide Midline CatheterC.R. Bard, Inc.201412
K140270Nexus Midline CT CatheterHealth Line International Corporation20141
K141026LeaderflexVygon20141
K142136Accucath Midline Catheter SystemVascular Pathways, Inc.20150
K130518Mini-Midline Extended Dwell Safety CatheterLuther Needlesafe Products, Inc.20130

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 8, 2014Class IIZ-1274-2015Nonconforming Material/ComponentSome unit packages of BD PosiFlush SF Saline Flush Syringe 10 mL may exhibit open seals, which could impact product sterility. Bard includes these pouched syringes, attached to some configurations of PICC kits, Port Access kits (PAK)…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 1.7 years on median.
  • 7 of the 21 ancestors have a recall of any class.
  • Of its descendants, K133856 (C.R. Bard, Inc., 2014) has gone furthest, with 12 descendants of its own.
  • 2 other devices also cite its predicate K112347.

How does its category compare?

All FOZ devices

FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · FOZ

11in 2025

2007: 62008: 92009: 92010: 32011: 62012: 132013: 42014: 92015: 102016: 92017: 92018: 12019: 82020: 102021: 42022: 82023: 92024: 62025: 112026 (partial year): 7
2007high 13 (2012) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FOZ

91in 2025

2007: 159 days median2008: 103 days median2009: 30 days median2010: 28 days median2011: 132 days median2012: 122 days median2013: 104 days median2014: 99 days median2015: 107 days median2016: 63 days median2017: 51 days median2019: 140 days median2020: 191 days median2021: 242 days median2022: 183 days median2023: 129 days median2024: 190 days median2025: 91 days median2026 (partial year): 203 days median
2007high 242 (2021) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FOZ

4in 2023

2007: 162009: 232010: 1152013: 22014: 42016: 3, 1 Class I2017: 222018: 42019: 32020: 32021: 12022: 4, 2 Class I2023: 4, 2 Class I2026 (partial year): 2
2007high 115 (2010) · low 0 (2008)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · FOZ

5,110in 2025

2007: 3742008: 4222009: 5082010: 3702011: 7862012: 5602013: 6402014: 8152015: 7292016: 9252017: 1,9662018: 3,3052019: 4,3652020: 3,7972021: 4,6742022: 4,1332023: 4,4302024: 4,7722025: 5,110
2007high 5,110 (2025) · low 370 (2010)2025

MAUDE reports naming product code FOZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007615916374
200891030422
200993023508
2010328115370
201161320786
2012131220560
201341042640
20149994815
2015101070729
20169633 (1)925
2017951221,966
20181—43,305
2019814034,365
20201019133,797
2021424214,674
202281834 (2)4,133
202391294 (2)4,430
2024619004,772
2025119105,110
202672032—

What is it indicated for?

The PowerGlide Midline Catheter is inserted into a patient's vascular system for short-term use (<30 days) to sample blood or administer fluids intravenously. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy and appropriateness of the procedure. The PowerGlide Midline Catheter is suitable for use with power injectors.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121073: Powerglide Midline Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121073

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026