510(k) Report

510(k) · Cleared

Cleared

Boston Keratoprosthesis or Boston Kpro

K121203510(k) TraditionalCleared May 10, 2013385-day reviewClass II21 CFR 886.3400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Massachusetts Eye & Ear Infirmary · HQM Keratoprosthesis, Permanent Implant

Cleared on May 10, 2013 as substantially equivalent to K915062 (Mackeen Consultants, Ltd., 1992) after a 385-day review. Its family tree reaches back 1 generation to 1992. 1 later device descends from it.

Decided
May 10, 2013
Review
385 days
Class
Class II
Product code
HQM
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K915062 (1992). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2019: 1 descendant clearedK915062 · Dohlman Doane Keratoprothesis · Mackeen Consultants, Ltd. · 19921990200020102020
Descendants, by generation 1 generation forward: 1 descendant K915062 · Dohlman Doane Keratoprothesis · Mackeen Consultants, Ltd. · 19920
  1. Root · 1 generation backK915062 Dohlman Doane KeratoprothesisMackeen Consultants, Ltd. · 1992
  2. This deviceK121203 Boston Keratoprosthesis or Boston KproMassachusetts Eye & Ear Infirmary · 2013
  3. Descendant · cites it directly · 0 of its ownK182986 Boston Keratoprosthesis, Type I LuciaMassachusetts Eye and Ear Infirmary D/B/A Boston · 2019

Most influential descendants

Showing 1 of 1 · See all
  • K182986Boston Keratoprosthesis, Type I LuciaMassachusetts Eye and Ear Infirmary D/B/A Boston · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K915062Dohlman Doane KeratoprothesisMackeen Consultants, Ltd.1992—
0 (this device)K121203Boston Keratoprosthesis or Boston KproMassachusetts Eye & Ear Infirmary2013—
+1K182986Boston Keratoprosthesis, Type I LuciaMassachusetts Eye and Ear Infirmary D/B/A Boston2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
FIG. 1 — Lineage of K121203, 1992–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HQM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K915062Dohlman Doane Keratoprothesis
Summary page 1
…886.3400 4. PREDICATE DEVICES Massachusetts Eye & Ear Infirmary's Keratoprosthesis previously cleared on January 21, 1992 under Premarket Notification Number K915062. 5. DEVICE DESCRIPTION The Boston Keratoprosthesis is an artificial comneal device that can be used in patients with severe…
Mackeen Consultants, Ltd.1992—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K182986Boston Keratoprosthesis, Type I LuciaMassachusetts Eye and Ear Infirmary D/B/A Boston20190

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K182986 (Massachusetts Eye and Ear Infirmary D/B/A Boston, 2019) has gone furthest, with 0 descendants of its own.

How does its category compare?

All HQM devices

HQM Keratoprosthesis, Permanent Implant: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · HQM

1in 2019

2013: 12019: 1
2007high 1 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HQM

Too few HQM 510(k)s in any year since 2007 to give a median.

Recalls per year · HQM

No recall names HQM since 2007.

Adverse event reports per year · HQM

3in 2013

2013: 3
2007high 3 (2013) · low 0 (2007)2025

MAUDE reports naming product code HQM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20131—03
20140—00
20150—00
20160—00
20170—00
20180—00
20191—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Boston Keratoprosthesis is indicated to provide a transparent optical pathway through an opacified cornea in an eye that is not a reasonable candidate for any form of corneal transplant, including penetrating keratoplasty.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121203: Boston Keratoprosthesis or Boston Kpro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121203

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026