510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Presson Electrode

K121347510(k) TraditionalCleared Jul 12, 201272-day reviewClass II21 CFR 882.1350Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rhythmlink International, LLC · GXZ Electrode, Needle

Cleared on Jul 12, 2012 after a 72-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it. It has been recalled once.

Decided
Jul 12, 2012
Review
72 days
Class
Class II
Product code
GXZ
Recalls
1
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2013: 1 descendant cleared2019: 1 descendant cleared2010201520202025
  1. This deviceK121347 Presson ElectrodeRhythmlink International, LLC · 2012
  2. Descendant · cites it directly · 1 of its ownK130220 MR Conditional Presson ElectrodeRhythmlink International, LLC · 2013
  3. Descendant · 2 generations on · 0 of its ownK190801 PressOn Electrode HeadsetRhythmlink International, LLC · 2019

Most influential descendants

Showing 2 of 2 · See all
  • K130220MR Conditional Presson ElectrodeRhythmlink International, LLC · 2013 · cites it directly1descendant
  • K190801PressOn Electrode HeadsetRhythmlink International, LLC · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K121347Presson ElectrodeRhythmlink International, LLC2012—
+1K130220MR Conditional Presson ElectrodeRhythmlink International, LLC2013—
+2K190801PressOn Electrode HeadsetRhythmlink International, LLC2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201910
FIG. 1 — Lineage of K121347, 2012–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXZ device

  1. #1 K231691 Phantom XL Insulated Dilatorsscore 10.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K130220MR Conditional Presson ElectrodeRhythmlink International, LLC20131

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 22, 2012Class IIZ-0752-2013Device DesignLag screw measurement is short (approximately 5 mm) when using current screw measuring device (p/n 101-00010) per the IO FIX Surgical Technique Rev C. which can lead to possible inappropriate implant size selection (e.g. shorter screw…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K130220 (Rhythmlink International, LLC, 2013) has gone furthest, with 1 descendant of its own.

How does its category compare?

All GXZ devices

GXZ Electrode, Needle: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · GXZ

1in 2024

2007: 32008: 22010: 12011: 22012: 12013: 22014: 22016: 12019: 22020: 12023: 22024: 1
2007high 3 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXZ

102in 2007

2007: 102 days median
2007high 102 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXZ

1in 2021

2010: 192021: 1
2007high 19 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXZ

75in 2025

2007: 22009: 22010: 42011: 42012: 122013: 62014: 82015: 122016: 112017: 62018: 92019: 142020: 72021: 92022: 182023: 212024: 582025: 75
2007high 75 (2025) · low 0 (2008)2025

MAUDE reports naming product code GXZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007310202
20082—00
20090—02
20101—194
20112—04
20121—012
20132—06
20142—08
20150—012
20161—011
20170—06
20180—09
20192—014
20201—07
20210—19
20220—018
20232—021
20241—058
20250—075
20260—0—

What is it indicated for?

The PressOn Electrode is intended for use in the recording of the Electroencephalogram (EEG), Evoked Potential (EP), or as Ground and Reference in an EEG or EP recording.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K121347: Presson Electrode.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121347

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026