510(k) · Cleared
ClearedReprocessed Ultrasound Intracardiac Echo Catheter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Stryker Sustainability Solutions, Inc. · OWQ Reprocessed Intravascular Ultrasound Catheter
Cleared on Dec 20, 2012 as substantially equivalent to K980851 (Boston Scientific Corp, 1998) after a 171-day review. Its family tree reaches back 2 generations to 1992.
- Decided
- Dec 20, 2012
- Review
- 171 days
- Class
- Class II
- Product code
- OWQ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K921750 (1992). 4 ancestors in all. No later device cites it as a predicate yet.
- Root · 2 generations backK921750 Cvis Insight Iii SystemCardiovascular Imaging Systems, Inc. · 1992
- 1 generation backK980851 Galaxy Intravascular Ultrasound System, Model I5028Boston Scientific Corp · 1998
- This deviceK121913 Reprocessed Ultrasound Intracardiac Echo CatheterStryker Sustainability Solutions, Inc. · 2012
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K921750 | Cvis Insight Iii System | Cardiovascular Imaging Systems, Inc. | 1992 | — |
| −1 | K980851 | Galaxy Intravascular Ultrasound System, Model I5028 | Boston Scientific Corp | 1998 | — |
| 0 (this device) | K121913 | Reprocessed Ultrasound Intracardiac Echo Catheter | Stryker Sustainability Solutions, Inc. | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OWQ device
- #1 K254149 Reprocessed AcuNav CRYSTAL™ Ultrasound…score 13.4 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K980851 | Galaxy Intravascular Ultrasound System, Model I5028Summary page 1…Cardiac Echo Catheter Classification Name: Ultrasonic Pulsed Echo Imaging Catheter Predicate Device 510(k) Title Mauatrer K980851 Galaxy Intravascular S stm -Ultrasound… | 1998 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 14.7 years on median.
- None of the 4 ancestors has a recall.
- 6 other devices also cite its predicate K980851.
How does its category compare?
All OWQ devicesOWQ Reprocessed Intravascular Ultrasound Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · OWQ
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OWQ
100in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OWQ
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OWQ
42in 2025
MAUDE reports naming product code OWQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 4 |
| 2014 | 0 | — | 1 | 2 |
| 2015 | 0 | — | 0 | 6 |
| 2016 | 2 | — | 0 | 5 |
| 2017 | 2 | — | 0 | 2 |
| 2018 | 1 | — | 0 | 2 |
| 2019 | 3 | 261 | 0 | 9 |
| 2020 | 1 | — | 0 | 29 |
| 2021 | 0 | — | 0 | 38 |
| 2022 | 2 | — | 0 | 24 |
| 2023 | 8 | 78 | 0 | 29 |
| 2024 | 1 | — | 0 | 37 |
| 2025 | 3 | 100 | 2 | 42 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Reprocessed Ultra IntraCardiac Echo Diagnostic Ultrasound rounded tip catheter is indicated for enhanced ultrasonic visualization of intracardiac structures.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K121913 · printed Nov 6, 2026
Cite this page
510(k) Report. “K121913: Reprocessed Ultrasound Intracardiac Echo Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121913
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026