510(k) Report

510(k) · Cleared

Cleared

Integra Interspinous Process System

K121924510(k) TraditionalCleared Sep 4, 2013429-day reviewClass II21 CFR 888.3050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Seaspine, Inc. · PEK Spinous Process Plate

Cleared on Sep 4, 2013 as substantially equivalent to K100407 (Life Spine, 2010) and 5 other predicates after a 429-day review. Its family tree reaches back 4 generations to 2004. 1 later device descends from it.

Decided
Sep 4, 2013
Review
429 days
Class
Class II
Product code
PEK
Recalls
None
Predicates
6

Its longest line of descent runs back 4 generations to K033826 (2004). 10 ancestors in all, the oldest K032037 (2003). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2010: 1 other ancestor2009: 1 other ancestor2008: 1 other ancestor2003: 1 other ancestor2007: 1 other ancestor2005: 1 other ancestor2018: 1 descendant clearedK033826 · Orthopedic Alliance Spine System · Orthopedic Alliance, LLC · 2004 · recalledK043484 · Lanx Spinal Fixation System · Lanx, LLC · 2005K071633 · Lanx Deformity System · Lanx, LLC · 2007K090252 · Modification to: Lanx Spinal Fixation System · Lanx, Inc. · 2009200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors2 generations back: 1 other ancestor3 generations back: 1 other ancestor 1 generation forward: 1 descendant K090252 · Modification to: Lanx Spinal Fixation System · Lanx, Inc. · 2009K071633 · Lanx Deformity System · Lanx, LLC · 2007K043484 · Lanx Spinal Fixation System · Lanx, LLC · 2005K033826 · Orthopedic Alliance Spine System · Orthopedic Alliance, LLC · 2004 · recalled0
  1. Root · 4 generations backK033826 Orthopedic Alliance Spine SystemOrthopedic Alliance, LLC · 2004 · Recalled
  2. 3 generations backK043484 Lanx Spinal Fixation SystemLanx, LLC · 2005
  3. 2 generations backK071633 Lanx Deformity SystemLanx, LLC · 2007
  4. 1 generation backK090252 Modification to: Lanx Spinal Fixation SystemLanx, Inc. · 2009
  5. This deviceK121924 Integra Interspinous Process SystemSeaspine, Inc. · 2013
  6. Descendant · cites it directly · 0 of its ownK173334 SeaSpine Spinous Process SystemSeaSpine Orthopedics Corporation · 2018

Most influential descendants

Showing 1 of 1 · See all
  • K173334SeaSpine Spinous Process SystemSeaSpine Orthopedics Corporation · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K033826Orthopedic Alliance Spine SystemOrthopedic Alliance, LLC20041
−3K043484Lanx Spinal Fixation SystemLanx, LLC2005—
−2K071633Lanx Deformity SystemLanx, LLC2007—
−1K090252Modification to: Lanx Spinal Fixation SystemLanx, Inc.2009—
0 (this device)K121924Integra Interspinous Process SystemSeaspine, Inc.2013—
+1K173334SeaSpine Spinous Process SystemSeaSpine Orthopedics Corporation2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200310
200510
200710
200810
200910
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
FIG. 1 — Lineage of K121924, 2004–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PEK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PEK device

  1. #1 K253250 Minuteman® G6 MIS Fusion Platescore 15.2 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100407Life Spine Interspinous Fixation System
Summary page 1
…lable predicate devices in design, materials, indications and performance: Life Spine interspinous Fixation System K100407 NuVasiveO Spinous Process Plate System K073278…
Life Spine2010—
*K073278Spinous Process Plate System
Summary page 1
…ndications and performance: Life Spine interspinous Fixation System K100407 NuVasiveO Spinous Process Plate System K073278 3 === Page 2 =…
Nuvasive, Inc.2008—
*K090252Modification to: Lanx Spinal Fixation System
Summary page 2
…510(k) Summary Page 2 of 2 Lonx Spinous Process Fusion Plate (SPFP) K090252; K083581; K043484 Medtronic CD Horizon Spinous Process P/ate K032037 Technological The t…
Lanx, Inc.2009—
*K083581Lanx Spinal Fixation System
Summary page 2
…510(k) Summary Page 2 of 2 Lonx Spinous Process Fusion Plate (SPFP) K090252; K083581; K043484 Medtronic CD Horizon Spinous Process P/ate K032037 Technological The technologi…
Lanx, Inc.2009—
*K043484Lanx Spinal Fixation System
Summary page 2
…510(k) Summary Page 2 of 2 Lonx Spinous Process Fusion Plate (SPFP) K090252; K083581; K043484 Medtronic CD Horizon Spinous Process P/ate K032037 Technological The technological chara…
Lanx, LLC2005—
*K032037CD Horizon (Addition of Spinous Process Plate)
Summary page 2
…of 2 Lonx Spinous Process Fusion Plate (SPFP) K090252; K083581; K043484 Medtronic CD Horizon Spinous Process P/ate K032037 Technological The technological characteristics of the Integra Spinous Process device are the Characteristics:…
Medtronic Sofamor Danek2003—

Also cleared against K100407: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173334SeaSpine Spinous Process SystemSeaSpine Orthopedics Corporation20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 4 companies; a new generation was cleared every 2.2 years on median.
  • 1 of the 10 ancestors has a recall of any class.
  • Of its descendants, K173334 (SeaSpine Orthopedics Corporation, 2018) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K100407.

How does its category compare?

All PEK devices

PEK Spinous Process Plate: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · PEK

1in 2025

2013: 102014: 82015: 62016: 42017: 32018: 42020: 22021: 22022: 32023: 42024: 12025: 12026 (partial year): 1
2007high 10 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PEK

60in 2023

2013: 118 days median2014: 120 days median2015: 166 days median2016: 176 days median2017: 94 days median2018: 69 days median2022: 135 days median2023: 60 days median
2007high 176 (2016) · low 60 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PEK

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PEK

3in 2025

2011: 22014: 22015: 32018: 22019: 42020: 22021: 172022: 112023: 82024: 52025: 3
2007high 17 (2021) · low 0 (2007)2025

MAUDE reports naming product code PEK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—02
20120—00
20131011800
2014812002
2015616603
2016417600
201739400
201846902
20190—04
20202—02
20212—117
20223135011
202346008
20241—05
20251—03
20261—0—

What is it indicated for?

Integra Spinous Process System is a posterior non-pedicle supplemental fixation system intended for use at a single level in the non-cervical spine (Ti-Si). It is intended for plate fixation/attachment to the spinous processes for the purpose of achieving supplemental fusion in the following conditions:

*degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies)

*spondylolisthesis

*trauma (i.e., fracture or dislocation)

*spinal tumor

The device is not intended for stand-alone use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121924: Integra Interspinous Process System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121924

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026