510(k) Report

510(k) · Cleared

Cleared

Spider Surgical Instruments, Flexible Monopolar Grasper Wavy Ratcheted, Spider Surgical Instruments, Flexible Monopolar

K122299510(k) TraditionalCleared Oct 25, 201286-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Transenterix, Inc. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Oct 25, 2012 as substantially equivalent to K091697 (Transenterix, Inc., 2009) and 2 other predicates after an 86-day review. Its family tree reaches back 2 generations to 1990. 1 later device descends from it.

Decided
Oct 25, 2012
Review
86 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K904578 (1990). 8 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2010: 1 other ancestor2009: 1 other ancestor1995: 1 other ancestor1992: 2 other ancestors1991: 1 other ancestor2013: 1 descendant clearedK904578 · Modification Auto Suture (R) Endoscopic Clamp · United States Surgical, A Division of Tyco Healthc · 1990K091869 · Sils Clincher, Sils Dissector, Sils Grasper, Sils L-Hook, Sils Shears · Covidien Lp, Formerly Registered AS United States · 20091990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 4 other ancestors 1 generation forward: 1 descendant K091869 · Sils Clincher, Sils Dissector, Sils Grasper, Sils L-Hook, Sils Shears · Covidien Lp, Formerly Registered AS United States · 2009K904578 · Modification Auto Suture (R) Endoscopic Clamp · United States Surgical, A Division of Tyco Healthc · 19900
  1. Root · 2 generations backK904578 Modification Auto Suture (R) Endoscopic ClampUnited States Surgical, A Division of Tyco Healthc · 1990
  2. 1 generation backK091869 Sils Clincher, Sils Dissector, Sils Grasper, Sils L-Hook, Sils ShearsCovidien Lp, Formerly Registered AS United States · 2009
  3. This deviceK122299 Spider Surgical Instruments, Flexible Monopolar Grasper Wavy…Transenterix, Inc. · 2012
  4. Descendant · cites it directly · 0 of its ownK124029 Microline Flexible Ligating ShearsMicroline Surgical, Inc. · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K124029Microline Flexible Ligating ShearsMicroline Surgical, Inc. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K904578Modification Auto Suture (R) Endoscopic ClampUnited States Surgical, A Division of Tyco Healthc1990—
−1K091869Sils Clincher, Sils Dissector, Sils Grasper, Sils L-Hook, Sils ShearsCovidien Lp, Formerly Registered AS United States2009—
0 (this device)K122299Spider Surgical Instruments, Flexible Monopolar Grasper Wavy Ratcheted, Spider…Transenterix, Inc.2012—
+1K124029Microline Flexible Ligating ShearsMicroline Surgical, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199220
199510
200910
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K122299, 1990–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091697Spider Surgical Instruments, Models 90004, 90005, 90007, 90009, 90010, 90012, 90013, 90015
Summary page 1
…Product Code: GEl 3. Predicate Devices: Class Manufacturer 510(k) Number Device Name/Description 11 TransEnterix K091697 SPIDER® Flexible Instruments: Maryland K102646 Dissector, Graspers (Blunt nose), Shear…
Transenterix, Inc.20092
*K102646Spider Flex Monopolar Hook
Summary page 1
…er 510(k) Number Device Name/Description 11 TransEnterix K091697 SPIDER® Flexible Instruments: Maryland K102646 Dissector, Graspers (Blunt nose), Shears 11 Covidien K091869 SILS' m Clincher, Graspers, Dissector…
Transenterix, Inc.2010—
*K091869Sils Clincher, Sils Dissector, Sils Grasper, Sils L-Hook, Sils Shears
Summary page 1
…K091697 SPIDER® Flexible Instruments: Maryland K102646 Dissector, Graspers (Blunt nose), Shears 11 Covidien K091869 SILS' m Clincher, Graspers, Dissector, Shears 4. Description: The S…
Covidien Lp, Formerly Registered AS United States2009—

Also cleared against K091697: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K124029Microline Flexible Ligating ShearsMicroline Surgical, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 3 companies; a new generation was cleared every 18.8 years on median.
  • 1 of the 8 ancestors has a recall of any class.
  • Of its descendants, K124029 (Microline Surgical, Inc., 2013) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K091697.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The SPIDER® Surgical Instruments are intended for use in minimally invasive abdominal laparoscopic surgical procedures for grasping, mobilizing, dissecting, retracting, cutting, cauterizing, ligating, suction/irrigation and other manipulation of tissues and vessels during laparoscopic procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122299: Spider Surgical Instruments, Flexible Monopolar Grasper Wavy Ratcheted, Spider Surgical Instruments, Flexible Monopolar.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K122299

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026