510(k) Report

510(k) · Cleared

Cleared

Myosure XL Rod Lens Hysteroscope, Myosure XL Outlfow Channel

K122563510(k) SpecialCleared Sep 19, 201228-day reviewClass II21 CFR 884.1690

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hologic, Inc. · HIH Hysteroscope (And Accessories)

Cleared on Sep 19, 2012 as substantially equivalent to K091465 (Interlace Medical, Inc., 2009) after a 28-day review. Its family tree reaches back 3 generations to 1995. 2 later devices descend from it.

Decided
Sep 19, 2012
Review
28 days
Class
Class II
Product code
HIH
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K954050 (1995). 9 ancestors in all, the oldest K941541 (1994). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2002: 1 other ancestor1996: 1 other ancestor1994: 1 other ancestor2000: 1 other ancestor1997: 1 other ancestor2018: 1 descendant cleared2019: 1 descendant clearedK954050 · Resectoscopes · KARL STORZ Endoscopy-America, Inc. · 1995K991563 · Continuous Flow Hystero-Resectoscope, Knife Electrode, Spike Electrode, Vaporisation Electrode, Coagulation Electrode, C · Henke Sass Wolf of America, Inc. · 1999K091465 · Myosure Rod Lens Hysteroscope · Interlace Medical, Inc. · 20091990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 4 other ancestors3 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant K091465 · Myosure Rod Lens Hysteroscope · Interlace Medical, Inc. · 2009K991563 · Continuous Flow Hystero-Resectoscope, Knife Electrode, Spike Electrode, Vaporisation Electrode, Coagulation Electrode, C · Henke Sass Wolf of America, Inc. · 1999K954050 · Resectoscopes · KARL STORZ Endoscopy-America, Inc. · 19950
  1. Root · 3 generations backK954050 ResectoscopesKARL STORZ Endoscopy-America, Inc. · 1995
  2. 2 generations backK991563 Continuous Flow Hystero-Resectoscope, Knife Electrode, Spike…Henke Sass Wolf of America, Inc. · 1999
  3. 1 generation backK091465 Myosure Rod Lens HysteroscopeInterlace Medical, Inc. · 2009
  4. This deviceK122563 Myosure XL Rod Lens Hysteroscope, Myosure XL Outlfow ChannelHologic, Inc. · 2012
  5. Descendant · cites it directly · 1 of its ownK182006 Omni Hysteroscope, Omni Hysteroscope Kits, Omni SheathsHologic, Inc. · 2018
  6. Descendant · 2 generations on · 0 of its ownK191281 Omni Hysteroscope, Omni Lok cervical sealHologic, Inc. · 2019

Most influential descendants

Showing 2 of 2 · See all
  • K182006Omni Hysteroscope, Omni Hysteroscope Kits, Omni SheathsHologic, Inc. · 2018 · cites it directly1descendant
  • K191281Omni Hysteroscope, Omni Lok cervical sealHologic, Inc. · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K954050ResectoscopesKARL STORZ Endoscopy-America, Inc.1995—
−2K991563Continuous Flow Hystero-Resectoscope, Knife Electrode, Spike Electrode…Henke Sass Wolf of America, Inc.1999—
−1K091465Myosure Rod Lens HysteroscopeInterlace Medical, Inc.2009—
0 (this device)K122563Myosure XL Rod Lens Hysteroscope, Myosure XL Outlfow ChannelHologic, Inc.2012—
+1K182006Omni Hysteroscope, Omni Hysteroscope Kits, Omni SheathsHologic, Inc.2018—
+2K191281Omni Hysteroscope, Omni Lok cervical sealHologic, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199610
199710
200010
200210
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
FIG. 1 — Lineage of K122563, 1995–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HIH device

  1. #1 K232003 Endoscopic Video Image Processor, Single-Use…score 16.1 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091465Myosure Rod Lens Hysteroscope
Summary page 1
…accessories Class: 11 Regulation number: 884.1690 Product code: HIB 3. Predicate Device: MyoSure Rod Lens Hysteroscope (K091465) 4. Device Description: The Myosure XL Rod Lens Hysteroscope is comprised of an oval 6.0 mm x 6.4mm G…
Interlace Medical, Inc.2009—

Also cleared against K091465: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K182006Omni Hysteroscope, Omni Hysteroscope Kits, Omni SheathsHologic, Inc.20181

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 3.9 years on median.
  • None of the 9 ancestors has a recall.
  • Of its descendants, K182006 (Hologic, Inc., 2018) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K091465.

How does its category compare?

All HIH devices

HIH Hysteroscope (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · HIH

3in 2025

2007: 12008: 22009: 42010: 42011: 32012: 42013: 52014: 22015: 52016: 32017: 22018: 82019: 142020: 72021: 42022: 22023: 42024: 62025: 32026 (partial year): 7
2007high 14 (2019) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HIH

111in 2025

2009: 130 days median2010: 109 days median2011: 118 days median2012: 25 days median2013: 144 days median2015: 52 days median2016: 106 days median2018: 135 days median2019: 91 days median2020: 88 days median2021: 194 days median2023: 200 days median2024: 148 days median2025: 111 days median2026 (partial year): 168 days median
2007high 200 (2023) · low 25 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HIH

3so far in 2026, the most since 2007

2019: 12023: 22026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HIH

1,698in 2025

2007: 72008: 122009: 172010: 312011: 592012: 782013: 1112014: 1252015: 2112016: 1722017: 3362018: 1822019: 2202020: 2532021: 1932022: 2892023: 1,4492024: 1,6112025: 1,698
2007high 1,698 (2025) · low 7 (2007)2025

MAUDE reports naming product code HIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—07
20082—012
20094130017
20104109031
20113118059
2012425078
201351440111
20142—0125
20155520211
201631060172
20172—0336
201881350182
201914911220
20207880253
202141940193
20222—0289
2023420021,449
2024614801,611
2025311101,698
202671683—

What is it indicated for?

The Myosure XL Rod Lens Hysteroscope is used to provide viewing of the cervical canal and the uterine cavity for the purpose of performing diagnostic and surgical procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122563: Myosure XL Rod Lens Hysteroscope, Myosure XL Outlfow Channel.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122563

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026