510(k) Report

510(k) · Cleared

Cleared

Advance Micro 14 Ultra Low Profile Balloon Dilatation Catheter Model PTA3

K122940510(k) TraditionalCleared Mar 19, 2013176-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook, Inc. · DQY Catheter, Percutaneous

Cleared on Mar 19, 2013 as substantially equivalent to K090822 (Cook, Inc., 2009) after a 176-day review. Its family tree reaches back 1 generation to 2009. 2 later devices descend from it.

Decided
Mar 19, 2013
Review
176 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K090822 (2009). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2014: 1 descendant clearedK090822 · Advance 14RX Rapid Exchange Pta Balloon Catheter · Cook, Inc. · 200920052010201520202025
Descendants, by generation 1 generation forward: 2 descendants K090822 · Advance 14RX Rapid Exchange Pta Balloon Catheter · Cook, Inc. · 20090
  1. Root · 1 generation backK090822 Advance 14RX Rapid Exchange Pta Balloon CatheterCook, Inc. · 2009
  2. This deviceK122940 Advance Micro 14 Ultra Low Profile Balloon Dilatation Catheter Model…Cook, Inc. · 2013
  3. Descendant · cites it directly · 0 of its ownK152934 MMS PTA Balloon CatheterMicro Medical Solutions, Inc. · 2016
  4. Descendant · cites it directly · 0 of its ownK140593 Advance Salivary Balloon Catheter with Wire GuideCook, Inc. · 2014

Most influential descendants

Showing 2 of 2 · See all
  • K152934MMS PTA Balloon CatheterMicro Medical Solutions, Inc. · 2016 · cites it directly0descendants
  • K140593Advance Salivary Balloon Catheter with Wire GuideCook, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K090822Advance 14RX Rapid Exchange Pta Balloon CatheterCook, Inc.2009—
0 (this device)K122940Advance Micro 14 Ultra Low Profile Balloon Dilatation Catheter Model PTA3Cook, Inc.2013—
+1K152934MMS PTA Balloon CatheterMicro Medical Solutions, Inc.2016—
+1K140593Advance Salivary Balloon Catheter with Wire GuideCook, Inc.2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201610
FIG. 1 — Lineage of K122940, 2009–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090822Advance 14RX Rapid Exchange Pta Balloon Catheter
Summary page 1
…21 CFR §870.1250 Product Code: DQY, LIT Predicate Device: Advance I4LP Low Profile PTA Balloon Dilatation Catheter D.C. #K090822, April 27, 2009 Cook Incorporated Advance Micro 14 Ultra Low-Profile PTA Balloon Catheter Traditional 510(k) De…
Cook, Inc.2009—

Also cleared against K090822: 2 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152934MMS PTA Balloon CatheterMicro Medical Solutions, Inc.20160
K140593Advance Salivary Balloon Catheter with Wire GuideCook, Inc.20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K152934 (Micro Medical Solutions, Inc., 2016) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K090822.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The Advance Micro 14 Ultra Low-Profile PTA Balloon Catheter is intended for percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries including internal pudendal, iliac, renal, popliteal, femoral, iliofemoral, anterior tibial, posterior tibial, peroneal, pedal, radial, brachial, and ulnar, as well as obstructive lesions of native or synthetic arteriovenous dialysis fistulae. Not for use in the coronary arteries.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122940: Advance Micro 14 Ultra Low Profile Balloon Dilatation Catheter Model PTA3.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122940

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026