510(k) Report

510(k) · Cleared

Cleared

Stryker Venom Electrodes and Cannulae

K123178510(k) TraditionalCleared Mar 28, 2013170-day reviewClass II21 CFR 882.4725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stryker Instruments, Instruments Div. · GXI Probe, Radiofrequency Lesion

Cleared on Mar 28, 2013 as substantially equivalent to K032406 (Stryker Instruments, 2004) and 2 other predicates after a 170-day review. Its family tree reaches back 8 generations to 1987. 2 later devices descend from it.

Decided
Mar 28, 2013
Review
170 days
Class
Class II
Product code
GXI
Recalls
None
Predicates
3

Its longest line of descent runs back 8 generations to K870028 (1987). 16 ancestors in all. 2 later devices descend from it, 2 citing it directly.

  1. Root · 8 generations backK870028 SMK Sluyter-Mehta Cannulae, RF Pole, Pole,FlexibleRadionics, Inc. · 1987
  2. 7 generations backK963577 Radionics Sluijter-Mehta CannulaRadionics, Inc. · 1996
  3. 6 generations backK980430 Radionics Disposable RF Cannulae (SC-C, RFK-DB, RFK-DS)Radionics, Inc. · 1998
  4. 5 generations backK021942 Radionics Pole NeedlesRadionics, A Division of Tyco Healthcare Group LP · 2002
  5. 4 generations backK042375 SMK, CX, Cxe, RCNTechnomed Europe · 2004
  6. 3 generations backK053415 Lesionpoint RF CannulaCosman Medical, Inc. · 2006
  7. 2 generations backK060799 Cosman CSK RF Cannula; Cosman RFK RF CannulaCosman Medical, Inc. · 2006
  8. 1 generation backK082012 Cosman RF Injection Electrodes, Models CU, Cur, CCD, TCD, CP, CR, CNCosman Medical, Inc. · 2008
  9. This deviceK123178 Stryker Venom Electrodes and CannulaeStryker Instruments, Instruments Div. · 2013
  10. Descendant · cites it directly · 0 of its ownK191293 LCCS VC-S RF CannulaLccs Products Limited · 2020
  11. Descendant · cites it directly · 0 of its ownK170242 MultiGen™ 2 RF Generator SystemStryker Corporation · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K191293LCCS VC-S RF CannulaLccs Products Limited · 2020 · cites it directly0descendants
  • K170242MultiGen™ 2 RF Generator SystemStryker Corporation · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K870028SMK Sluyter-Mehta Cannulae, RF Pole, Pole,FlexibleRadionics, Inc.1987—
−7K963577Radionics Sluijter-Mehta CannulaRadionics, Inc.1996—
−6K980430Radionics Disposable RF Cannulae (SC-C, RFK-DB, RFK-DS)Radionics, Inc.1998—
−5K021942Radionics Pole NeedlesRadionics, A Division of Tyco Healthcare Group LP2002—
−4K042375SMK, CX, Cxe, RCNTechnomed Europe2004—
−3K053415Lesionpoint RF CannulaCosman Medical, Inc.2006—
−2K060799Cosman CSK RF Cannula; Cosman RFK RF CannulaCosman Medical, Inc.2006—
−1K082012Cosman RF Injection Electrodes, Models CU, Cur, CCD, TCD, CP, CR, CNCosman Medical, Inc.2008—
0 (this device)K123178Stryker Venom Electrodes and CannulaeStryker Instruments, Instruments Div.2013—
+1K191293LCCS VC-S RF CannulaLccs Products Limited2020—
+1K170242MultiGen™ 2 RF Generator SystemStryker Corporation2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
199910
200010
200110
200210
200420
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202010
FIG. 1 — Lineage of K123178, 1987–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXI device

  1. #1 K253907 Disposable Radiofrequency Cannulascore 12.7 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032406Stryker RF Electrodes and Cannulae
Summary page 1
…ion Name: probe, radiofrequency lesion; GXI 3. Legally Marketed Predicate Device(s) 5 10(k) Number Product Code Trade Name Manufacturer K032406 GXI Strykerg) Monopolar Stryker Instruments Electrodes…
Stryker Instruments20043
*K082012Cosman RF Injection Electrodes, Models CU, Cur, CCD, TCD, CP, CR, CN
Summary page 2
…son Stryker® VdnomTM Stryker@ Monopolar Cosman REF Comparison Electrodes and Electrodes and Electrodes (K082012) Cannulae Cannulae (K032406) and Cannulac…
Cosman Medical, Inc.2008—
*K060799Cosman CSK RF Cannula; Cosman RFK RF Cannula
Summary page 1
…Manufacturer K032406 GXI Strykerg) Monopolar Stryker Instruments Electrodes and Cannulae K060799 GXI Cosman REF Cannula Cosman Medical, Inc. 4. Device Description The Stryker Cannulae w…
Cosman Medical, Inc.2006—

Also cleared against K032406: 3 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191293LCCS VC-S RF CannulaLccs Products Limited20200
K170242MultiGen™ 2 RF Generator SystemStryker Corporation20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 5 companies; a new generation was cleared every 2.5 years on median.
  • 3 of the 16 ancestors have a recall of any class.
  • Of its descendants, K191293 (Lccs Products Limited, 2020) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K032406.

How does its category compare?

All GXI devices

GXI Probe, Radiofrequency Lesion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · GXI

4in 2025

2007: 42008: 22009: 22010: 22011: 32012: 12013: 12014: 12015: 12016: 32017: 32018: 12019: 32020: 32022: 22025: 42026 (partial year): 2
2007high 4 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXI

183in 2025

2007: 87 days median2011: 64 days median2016: 240 days median2017: 125 days median2019: 63 days median2020: 255 days median2025: 183 days median
2007high 255 (2020) · low 63 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXI

1in 2019

2007: 32008: 12010: 12012: 12013: 12017: 12019: 12026 (partial year): 3
2007high 3 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXI

98in 2025

2007: 12008: 42009: 102010: 82011: 52012: 142013: 252014: 202015: 232016: 162017: 1502018: 1472019: 932020: 312021: 302022: 462023: 352024: 452025: 98
2007high 150 (2017) · low 1 (2007)2025

MAUDE reports naming product code GXI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200748731
20082—14
20092—010
20102—18
201136405
20121—114
20131—125
20141—020
20151—023
20163240016
201731251150
20181—0147
2019363193
20203255031
20210—030
20222—046
20230—035
20240—045
20254183098
20262—3—

What is it indicated for?

The Stryker RF electrodes and cannulae, in combination with the Stryker RF Generator/Multigen, are intended for coagulation of soft tissues in orthopedic, spinal, and neurosurgical applications. These products are also used for selective dlenervation and tissue destruction procedures which may be performed on the lumbar, thoracic, and cervical regions of the peripheral nerves, and nerve roots for the relief of pain. Examples include, but are not limited to, Facette Denervation, Trigeminus Neuralgia, Peripheral Neuralgia and Rhizotomy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123178: Stryker Venom Electrodes and Cannulae.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123178

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026