510(k) Report

510(k) · Cleared

Cleared

Diagnostic Ultrasound System

K123249510(k) TraditionalCleared Feb 8, 2013114-day reviewClass II21 CFR 892.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Edan Instruments, Inc. · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Feb 8, 2013 as substantially equivalent to K110999 (Edan Instruments, Inc., 2011) and 3 other predicates after a 114-day review. Its family tree reaches back 18 generations to 1995. 21 later devices descend from it.

Decided
Feb 8, 2013
Review
114 days
Class
Class II
Product code
IYN
Recalls
None
Predicates
4

Its longest line of descent runs back 18 generations to K935595 (1995). 125 ancestors in all, the oldest K852159 (1985). 21 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 1 other ancestor2008: 3 other ancestors2009: 3 other ancestors2007: 5 other ancestors2006: 8 other ancestors2004: 14 other ancestors2001: 9 other ancestors1999: 8 other ancestors2005: 10 other ancestors2003: 10 other ancestors2002: 6 other ancestors2000: 7 other ancestors1998: 1 other ancestor1997: 4 other ancestors1996: 3 other ancestors1995: 5 other ancestors1994: 6 other ancestors1992: 2 other ancestors1985: 1 other ancestor1987: 1 other ancestor2015: 2 descendants cleared2013: 2 descendants cleared2017: 7 descendants cleared2016: 2 descendants cleared2019: 3 descendants cleared2018: 2 descendants cleared2020: 1 descendant cleared2021: 1 descendant cleared2025: 1 descendant clearedK935595 · Acuson Model 3001 · Acuson Corp. · 1995K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K032111 · Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK040060 · Sonoline G50 and G60 S Diagnostic Ultrasound Systems · Siemens Medical Solutions USA, Inc. · 2004K043078 · Nemio Diagnostic Ultrasound System, Model Ssa-550A · Toshiba America Medical Systems, In.C · 2004 · recalledK051500 · Famio Diagnostic Ultrasound Systems, Model Ssa-530A · Toshiba America Medical Systems, In.C · 2005K053346 · Modification to: DP-9900 Digital Ultrasonic Diagnostic Imaging System, Model DP-9900 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2005K061189 · DP-9900 Digital Ultrasonic Diagnostic Imaging System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006K063500 · DC-6 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006K072164 · DC-6 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2007×2: 2 generations cleared close together, K080640 (2008), K081320 (2008) K083505 · DC-3/DC-3T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008×2: 2 generations cleared close together, K091941 (2009), K092691 (2009) K100830 · M7/M7T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010K102991 · M5 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 20101990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 9 other ancestors3 generations back: 23 other ancestors4 generations back: 18 other ancestors5 generations back: 30 other ancestors6 generations back: 15 other ancestors7 generations back: 9 other ancestors8 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 6 descendants3 generations forward: 2 descendants4 generations forward: 1 descendant5 generations forward: 2 descendants6 generations forward: 3 descendants7 generations forward: 2 descendants K102991 · M5 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010K100830 · M7/M7T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010K092691 · DC-7 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2009K091941 · DC-3/DC-3T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2009K083505 · DC-3/DC-3T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008K081320 · DC-3, DC-3T Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008K080640 · M5 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008K072164 · DC-6 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2007K063500 · DC-6 Diagnostic Ultrasound System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006K061189 · DP-9900 Digital Ultrasonic Diagnostic Imaging System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006K053346 · Modification to: DP-9900 Digital Ultrasonic Diagnostic Imaging System, Model DP-9900 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2005K051500 · Famio Diagnostic Ultrasound Systems, Model Ssa-530A · Toshiba America Medical Systems, In.C · 2005K043078 · Nemio Diagnostic Ultrasound System, Model Ssa-550A · Toshiba America Medical Systems, In.C · 2004 · recalledK040060 · Sonoline G50 and G60 S Diagnostic Ultrasound Systems · Siemens Medical Solutions USA, Inc. · 2004K032111 · Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K935595 · Acuson Model 3001 · Acuson Corp. · 1995−15−10−50+5
  1. Root · 18 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 14 generations between
  3. 3 generations backK092691 DC-7 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2009
  4. 2 generations backK100830 M7/M7T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010
  5. 1 generation backK102991 M5 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010
  6. This deviceK123249 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2013
  7. Descendant · cites it directly · 13 of its ownK142511 U50 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2015
  8. Descendant · cites it directly · 12 of its ownK150999 Acclarix Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2015
  9. Descendant · 2 generations on · 9 of its ownK161300 Acclarix AX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2016
  10. Descendant · 2 generations on · 9 of its ownK160790 Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2016
  11. Descendant · 3 generations on · 8 of its ownK162055 Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2017
Show all 18 generations
  1. Root · 18 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 17 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
  3. 16 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
  4. 15 generations backK032111 Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2003 · Recalled
  5. 14 generations backK040060 Sonoline G50 and G60 S Diagnostic Ultrasound SystemsSiemens Medical Solutions USA, Inc. · 2004
  6. 13 generations backK043078 Nemio Diagnostic Ultrasound System, Model Ssa-550AToshiba America Medical Systems, In.C · 2004 · Recalled
  7. 12 generations backK051500 Famio Diagnostic Ultrasound Systems, Model Ssa-530AToshiba America Medical Systems, In.C · 2005
  8. 11 generations backK053346 Modification to: DP-9900 Digital Ultrasonic Diagnostic Imaging…Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2005
  9. 10 generations backK061189 DP-9900 Digital Ultrasonic Diagnostic Imaging SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006
  10. 9 generations backK063500 DC-6 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006
  11. 8 generations backK072164 DC-6 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2007
  12. 7 generations backK080640 M5 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008
  13. 6 generations backK081320 DC-3, DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008
  14. 5 generations backK083505 DC-3/DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2008
  15. 4 generations backK091941 DC-3/DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2009
  16. 3 generations backK092691 DC-7 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2009
  17. 2 generations backK100830 M7/M7T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010
  18. 1 generation backK102991 M5 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2010
  19. This deviceK123249 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2013

Showing 5 of 21 descendants. See all descendants

Descendants cleared per year

2013: 22015: 22016: 22017: 72018: 22019: 32020: 12021: 12025: 1
2013high 7 (2017) · low 0 (2014)2026

Most influential descendants

Showing 5 of 21 · See all
  • K142511U50 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2015 · cites it directly13descendants
  • K150999Acclarix Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2015 · cites it directly12descendants
  • K161300Acclarix AX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2016 · 2 generations on9descendants
  • K160790Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2016 · 2 generations on9descendants
  • K162055Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc. · 2017 · 3 generations on8descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−18K935595Acuson Model 3001Acuson Corp.1995—
−17K973767Harmonic Imaging with ContrastAcuson Corp.1997—
−16K022567Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp.2002—
−15K032111Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20031
−14K040060Sonoline G50 and G60 S Diagnostic Ultrasound SystemsSiemens Medical Solutions USA, Inc.2004—
−13K043078Nemio Diagnostic Ultrasound System, Model Ssa-550AToshiba America Medical Systems, In.C20041
−12K051500Famio Diagnostic Ultrasound Systems, Model Ssa-530AToshiba America Medical Systems, In.C2005—
−11K053346Modification to: DP-9900 Digital Ultrasonic Diagnostic Imaging System, Model…Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2005—
−10K061189DP-9900 Digital Ultrasonic Diagnostic Imaging SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2006—
−9K063500DC-6 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2006—
−8K072164DC-6 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2007—
−7K080640M5 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2008—
−6K081320DC-3, DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2008—
−5K083505DC-3/DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2008—
−4K091941DC-3/DC-3T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2009—
−3K092691DC-7 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2009—
−2K100830M7/M7T Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2010—
−1K102991M5 Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2010—
0 (this device)K123249Diagnostic Ultrasound SystemEdan Instruments, Inc.2013—
+1K142511U50 Diagnostic Ultrasound SystemEdan Instruments, Inc.2015—
+1K150999Acclarix Diagnostic Ultrasound SystemEdan Instruments, Inc.2015—
+2K161300Acclarix AX8 Diagnostic Ultrasound SystemEdan Instruments, Inc.2016—
+2K160790Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc.2016—
+3K162055Acclarix LX8 Diagnostic Ultrasound SystemEdan Instruments, Inc.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198710
199220
199460
199550
199630
199740
199810
199980
200070
200190
200260
2003100
2004140
2005100
200680
200750
200830
200930
201110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201320
201520
201620
201770
201820
201930
202010
202110
202510
FIG. 1 — Lineage of K123249, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110999Digital Ultrasonic Diagnostic Imaging SystemEdan Instruments, Inc.2011—
*K072164DC-6 Diagnostic Ultrasound System
Summary page 1
…DUS 60 Digital Ultrasonic Diagnostic Imaging System /Kl 10999/ Device: Edan Instruments, Inc. DC-6 Diagnostic Ultrasound System / K072 164 / Shenzhen Mindray Bio-medical Electronics Co.; Ltd. M5 Diagnostic Ultrasound Syste…
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2007—
*K102991M5 Diagnostic Ultrasound System
Summary page 1
…gnostic Ultrasound System / K072 164 / Shenzhen Mindray Bio-medical Electronics Co.; Ltd. M5 Diagnostic Ultrasound System / K102991 / Shenzhen Mindray Bio-medical Electronics Co., Ltd. GE LOGIQ E9 Diagnostic Ultraso…
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2010—
*K082185GE Logiq E9 Diagnostic Ultrasound System, Models 5205000, 5205000-2
Summary page 1
…Ultrasound System / K102991 / Shenzhen Mindray Bio-medical Electronics Co., Ltd. GE LOGIQ E9 Diagnostic Ultrasound System! K082 185/ General Electric Co.…
Ge Medical Systems Ultrasound and Primary Care Dia20081

Also cleared against K110999: 1 other device →

What descends from it? (21)

See all 21

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142511U50 Diagnostic Ultrasound SystemEdan Instruments, Inc.201513
K150999Acclarix Diagnostic Ultrasound SystemEdan Instruments, Inc.201512
K131830Digital Ultrasonic Diagnostic Imaging SystemEdan Instruments, Inc.20131
K163688Medisono Ultrasonic Diagnostic Imaging System, models P1, P3, and P10Medisono, LLC20170
K132059Diagnostic Ultrasound SystemAdvanced Instrumentations, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 7 months on median.
  • 27 of the 125 ancestors have a recall of any class.
  • Of its descendants, K142511 (Edan Instruments, Inc., 2015) has gone furthest, with 13 descendants of its own.
  • 1 other device also cites its predicate K110999.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The diagnostic ultrasound system (U50) is applicable for adults, pregnant women, pediatric patients' ultrasound evaluation in hospitals and clinics. It is intended for use in abdominal, obstetrics, gynecology, pediatric, small parts, urology, peripheral vascular, musculoskeletal (conventional and superficial), transvaginal and cardiac clinical applications, by or on the order of a physician or similarly qualified health care professional.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123249: Diagnostic Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K123249

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026