510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Stride Unicondylar Knee

K123380510(k) TraditionalCleared May 31, 2013211-day reviewClass II21 CFR 888.3520Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Blue Belt Technologies, Inc. · HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

Cleared on May 31, 2013 as substantially equivalent to K033363 (Zimmer, Inc., 2004) and 1 other predicate after a 211-day review. Its family tree reaches back 5 generations to 1997. 11 later devices descend from it. It has been recalled 2 times.

Decided
May 31, 2013
Review
211 days
Class
Class II
Product code
HSX
Recalls
2
Predicates
2

Its longest line of descent runs back 5 generations to K971938 (1997). 18 ancestors in all, the oldest K880155 (1988). 11 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 2 other ancestors2001: 3 other ancestors1988: 1 other ancestor2007: 1 other ancestor2006: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestor2003: 1 other ancestor1996: 1 other ancestor1993: 1 other ancestor2017: 2 descendants cleared2019: 3 descendants cleared2021: 4 descendants cleared2026: 2 descendants clearedK971938 · Repicci II Unicondylar Knee · Biomet, Inc. · 1997 · recalled×2: 2 generations cleared close together, K020741 (2002), K022437 (2002) ×2: 2 generations cleared close together, K080368 (2008), K082081 (2008) 1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors3 generations back: 7 other ancestors4 generations back: 3 other ancestors 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 3 descendants4 generations forward: 1 descendant K082081 · Mako Surgical Corporation Unicondylar Knee Implant System Iii · Mako Surgical Corp. · 2008K080368 · Mako Surgical Corp. Unicondylar Knee Implant System II · Mako Surgical Corp. · 2008K022437 · Uni Knee · Encore Medical L.P. · 2002 · recalledK020741 · Unicondylar Knee · Encore Orthopedics, Inc. · 2002 · recalledK971938 · Repicci II Unicondylar Knee · Biomet, Inc. · 1997 · recalled−50
  1. Root · 5 generations backK971938 Repicci II Unicondylar KneeBiomet, Inc. · 1997 · Recalled
  2. 4 generations backK020741 Unicondylar KneeEncore Orthopedics, Inc. · 2002 · Recalled
  3. 3 generations backK022437 Uni KneeEncore Medical L.P. · 2002 · Recalled
  4. 2 generations backK080368 Mako Surgical Corp. Unicondylar Knee Implant System IIMako Surgical Corp. · 2008
  5. 1 generation backK082081 Mako Surgical Corporation Unicondylar Knee Implant System IiiMako Surgical Corp. · 2008
  6. This deviceK123380 Stride Unicondylar KneeBlue Belt Technologies, Inc. · 2013
  7. Descendant · cites it directly · 8 of its ownK163700 Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2017
  8. Descendant · 2 generations on · 7 of its ownK181302 Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2019
  9. Descendant · 2 generations on · 4 of its ownK191150 Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2019
  10. Descendant · 2 generations on · 3 of its ownK191996 BC Reflex Uni Knee SystemBodycad Laboratories, Inc. · 2019
  11. Descendant · 3 generations on · 2 of its ownK203697 BC Reflex Uni Knee SystemBodycad Laboratories, Inc. · 2021

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2017: 22019: 32021: 42026: 2
2017high 4 (2021) · low 0 (2018)2026

Most influential descendants

Showing 5 of 11 · See all
  • K163700Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2017 · cites it directly8descendants
  • K181302Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2019 · 2 generations on7descendants
  • K191150Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc. · 2019 · 2 generations on4descendants
  • K191996BC Reflex Uni Knee SystemBodycad Laboratories, Inc. · 2019 · 2 generations on3descendants
  • K203697BC Reflex Uni Knee SystemBodycad Laboratories, Inc. · 2021 · 3 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K971938Repicci II Unicondylar KneeBiomet, Inc.19971
−4K020741Unicondylar KneeEncore Orthopedics, Inc.20022
−3K022437Uni KneeEncore Medical L.P.20022
−2K080368Mako Surgical Corp. Unicondylar Knee Implant System IIMako Surgical Corp.2008—
−1K082081Mako Surgical Corporation Unicondylar Knee Implant System IiiMako Surgical Corp.2008—
0 (this device)K123380Stride Unicondylar KneeBlue Belt Technologies, Inc.2013—
+1K163700Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc.2017—
+2K181302Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc.2019—
+2K191150Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc.2019—
+2K191996BC Reflex Uni Knee SystemBodycad Laboratories, Inc.2019—
+3K203697BC Reflex Uni Knee SystemBodycad Laboratories, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199310
199610
199810
199910
200130
200310
200420
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201720
201930
202140
202620
FIG. 1 — Lineage of K123380, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HSX device

  1. #1 K261609 Freedom Partial Knee Systemscore 15.1 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033363Zimmer Unicompartmental Knee System
Summary page 1
…opedic PREDICATE DEVICES: The predicate devices for the STRIDE Unicondylar Knee are the Zimmer@ Unicompartmental Knee System, K033363 (cleared 1/16/2004); and the MAKO Surgical Corporation Unicondylar…
Zimmer, Inc.20043
*K082081Mako Surgical Corporation Unicondylar Knee Implant System Iii
Summary page 1
…System, K033363 (cleared 1/16/2004); and the MAKO Surgical Corporation Unicondylar Knee Implant System Ill, K082081 (cleared 8/15/2008). Blue Belt Technologies, Inc. 4-17-2013…
Mako Surgical Corp.2008—

Also cleared against K033363: 21 other devices →

What descends from it? (11)

See all 11

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K163700Bodycad Unicompartmental Knee SystemBodycad Laboratories, Inc.20178
K170344Tahoe Uni Knee SystemConsensus Orthopedics, Inc.20171

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 4, 2014Class IIZ-1943-2014Labeling mix-upsMislabeled. Packages labeled PFSI-00053, Right Lateral/Left Medial contains PFSI-00054, Right Medial/Left lateral implants. Packages labeled PFSI-00054, Stride Right Medial/Left Lateral contain PFSI-00053, Left Medial/Right Lateral.
Jun 4, 2014Class IIZ-1942-2014Labeling mix-upsMislabeled. Packages labeled PFSI-00053, Right Lateral/Left Medial contains PFSI-00054, Right Medial/Left lateral implants. Packages labeled PFSI-00054, Stride Right Medial/Left Lateral contain PFSI-00053, Left Medial/Right Lateral.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 4.6 years on median.
  • 9 of the 18 ancestors have a recall of any class.
  • Of its descendants, K163700 (Bodycad Laboratories, Inc., 2017) has gone furthest, with 8 descendants of its own.
  • 21 other devices also cite its predicate K033363.

How does its category compare?

All HSX devices

HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · HSX

4in 2025

2007: 62008: 42009: 22010: 32011: 12012: 52013: 22015: 12016: 32017: 52018: 22019: 72020: 42021: 72022: 22023: 12024: 42025: 42026 (partial year): 2
2007high 7 (2019) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HSX

59in 2025

2007: 33 days median2008: 102 days median2010: 74 days median2012: 88 days median2016: 147 days median2017: 160 days median2019: 90 days median2020: 40 days median2021: 81 days median2024: 133 days median2025: 59 days median
2007high 160 (2017) · low 33 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HSX

2in 2020

2009: 492013: 12016: 12017: 42020: 2
2007high 49 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HSX

175in 2025

2007: 62008: 42009: 212010: 582011: 1142012: 832013: 792014: 662015: 572016: 1072017: 1132018: 1592019: 1772020: 2732021: 2402022: 2572023: 2312024: 1722025: 175
2007high 273 (2020) · low 4 (2008)2025

MAUDE reports naming product code HSX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200763306
2008410204
20092—4921
2010374058
20111—0114
2012588083
20132—179
20140—066
20151—057
201631471107
201751604113
20182—0159
20197900177
20204402273
20217810240
20222—0257
20231—0231
202441330172
20254590175
20262—0—

What is it indicated for?

The STRIDE Unicondylar Knee devices are indicated for patients with:

- Painful and/or disabling knee joints due to osteoarthritis or traumatic arthritis.

- Previous tibial condyle or plateau fractures with loss of anatomy or function.

- Varus or valgus deformities.

- Revision of previous arthroplasty procedures.

These devices are indicated for cemented use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123380: Stride Unicondylar Knee.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K123380

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026