510(k) Report

510(k) · Cleared

Cleared

Niox Panel for Use with the Niox Mino Airway Inflammation Monitor

K123683510(k) SpecialCleared Dec 27, 201227-day reviewClass II21 CFR 862.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aerocrine AB · MXA System, Test, Breath Nitric Oxide

Cleared on Dec 27, 2012 as substantially equivalent to K101034 (Aerocrine AB, 2010) after a 27-day review. Its family tree reaches back 3 generations to 2003.

Decided
Dec 27, 2012
Review
27 days
Class
Class II
Product code
MXA
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to DEN030001 (2003). No later device cites it as a predicate yet.

  1. Root · 3 generations backDEN030001 Niox Article NO: 02-1000Aerocrine AB · 2003
  2. 2 generations backK072816 Niox MinoAerocrine AB · 2008
  3. 1 generation backK101034 Niox Mino Model 09-1000Aerocrine AB · 2010
  4. This deviceK123683 Niox Panel for Use with the Niox Mino Airway Inflammation MonitorAerocrine AB · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN030001Niox Article NO: 02-1000Aerocrine AB2003—
−2K072816Niox MinoAerocrine AB2008—
−1K101034Niox Mino Model 09-1000Aerocrine AB2010—
0 (this device)K123683Niox Panel for Use with the Niox Mino Airway Inflammation MonitorAerocrine AB2012—
FIG. 1 — Lineage of K123683, 2003–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MXA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MXA device

  1. #1 K251674 Fenom Flo™ FeNO Monitoring Systemscore 11.3 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K101034Niox Mino Model 09-1000
Summary page 1
…additional display for the NIOX MINO® Airway Inflammation Monitor. Predicate Device: NIOX MINO® Airway Inflammation Monitor 510(k) Clearance Number: K101034 510(k) Holder/Submitter: Aerocrine AB Sundbybergsv~gen 9 S…
Aerocrine AB2010—

Also cleared against K101034: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 1 company; a new generation was cleared every 2.5 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K101034.

How does its category compare?

All MXA devices

MXA System, Test, Breath Nitric Oxide: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · MXA

2in 2025

2008: 22009: 12010: 12012: 12014: 12015: 12017: 12019: 12021: 12023: 12024: 12025: 2
2007high 2 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MXA

Too few MXA 510(k)s in any year since 2007 to give a median.

Recalls per year · MXA

No recall names MXA since 2007.

Adverse event reports per year · MXA

No MAUDE report names MXA since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—00
20091—00
20101—00
20110—00
20121—00
20130—00
20141—00
20151—00
20160—00
20171—00
20180—00
20191—00
20200—00
20211—00
20220—00
20231—00
20241—00
20252—00
20260—0—

What is it indicated for?

NIOX MINO measures Nitric Oxide (NO) in human breath. Nitric Oxide is frequently increased in some inflammatory processes such as asthma. The fractional NO concentration in expired breath (FeNO), can be measured by NIOX MINO according to guidelines for NO measurement established by the American Thoracic Society. Measurement of FeNO by NIOX MINO is a quantitative, non-invasive, simple and safe method to measure the decrease in FeNO concentration in asthma…

Read the full statement (205 words)

NIOX MINO measures Nitric Oxide (NO) in human breath. Nitric Oxide is frequently increased in some inflammatory processes such as asthma. The fractional NO concentration in expired breath (FeNO), can be measured by NIOX MINO according to guidelines for NO measurement established by the American Thoracic Society.

Measurement of FeNO by NIOX MINO is a quantitative, non-invasive, simple and safe method to measure the decrease in FeNO concentration in asthma patients that often occurs after treatment with anti-inflammatory pharmacological therapy, as an indication of the therapeutic effect in patients with elevated FeNO levels. NIOX MINO is suitable for children approximately 7 - 17 years, and adults 18 years and older.

FeNO measurements provide the physician with means of evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to the established clinical and laboratory assessments in asthma. NIOX MINO should only be used as directed in the NIOX MINO User Manual and the NIOX MINO Quality Control Test User Manual, by trained physicians, nurses, respiratory therapists and laboratory technicians. NIOX MINO cannot be used with infants or by children approximately under the age of 7, as measurement requires patient cooperation. NIOX MINO should not be used in critical care, emergency care or in anaesthesiology.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123683: Niox Panel for Use with the Niox Mino Airway Inflammation Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K123683

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026