510(k) Report

510(k) · Cleared

Cleared

Medusa Vascular Plug

K123696510(k) TraditionalCleared Oct 25, 2013326-day reviewClass II21 CFR 870.3300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Endoshape, Inc. · KRD Device, Vascular, For Promoting Embolization

Cleared on Oct 25, 2013 as substantially equivalent to K031810 (Aga Medical Corp., 2003) after a 326-day review. Its family tree reaches back 6 generations to 1989. 1 later device descends from it.

Decided
Oct 25, 2013
Review
326 days
Class
Class II
Product code
KRD
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K891688 (1989). 15 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 6 generations backK891688 Coil and Coil Delivery SystemTarget Therapeutics · 1989
  2. 5 generations backK964367 Ces Vascular Occlusion SystemCordis Neurovascular, Inc. · 1997
  3. 4 generations backK972881 Ces Vascular Occlusion SystemCordis Neurovascular, Inc. · 1998
  4. 3 generations backK983483 Vascular Occlusion SystemCordis Neurovascular, Inc. · 1999
  5. 2 generations backK993455 Flipper Detachable Embolization CoilCook, Inc. · 2000
  6. 1 generation backK031810 Amplatzer Vascular PlugAga Medical Corp. · 2003 · Recalled
  7. This deviceK123696 Medusa Vascular PlugEndoshape, Inc. · 2013
  8. Descendant · cites it directly · 0 of its ownK140796 Medusa Vascular Plug,Endoshape, Inc. · 2014

Most influential descendants

Showing 1 of 1 · See all
  • K140796Medusa Vascular Plug,Endoshape, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K891688Coil and Coil Delivery SystemTarget Therapeutics1989—
−5K964367Ces Vascular Occlusion SystemCordis Neurovascular, Inc.1997—
−4K972881Ces Vascular Occlusion SystemCordis Neurovascular, Inc.1998—
−3K983483Vascular Occlusion SystemCordis Neurovascular, Inc.1999—
−2K993455Flipper Detachable Embolization CoilCook, Inc.2000—
−1K031810Amplatzer Vascular PlugAga Medical Corp.20031
0 (this device)K123696Medusa Vascular PlugEndoshape, Inc.2013—
+1K140796Medusa Vascular Plug,Endoshape, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199020
199110
199420
199510
199630

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
FIG. 1 — Lineage of K123696, 1989–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRD device

  1. #1 K253511 Concerto Versa™ Detachable Coilscore 17.6 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031810Amplatzer Vascular Plug
Summary page 1
…evice Classification: 21 CFR§870.3300, Class 11 Product Code: ERD PREDICATE DEVICE(S) * Cook Embolization Coils (Pre-Amendment) * Amplatzer Vascular Plug (K031810) PACE 11 ENDOSHAPE, INC.…
Aga Medical Corp.20031
*—Cook Embolization Coils (Pre-Amendment)
Named without a submission number
—

Also cleared against K031810: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K140796Medusa Vascular Plug,Endoshape, Inc.20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 5 companies; a new generation was cleared every 3.7 years on median.
  • 3 of the 15 ancestors have a recall of any class.
  • Of its descendants, K140796 (Endoshape, Inc., 2014) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K031810.

How does its category compare?

All KRD devices

KRD Device, Vascular, For Promoting Embolization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · KRD

9in 2025

2007: 22008: 52009: 42010: 32011: 52012: 82013: 112014: 72015: 112016: 42017: 42018: 42019: 62020: 42021: 32022: 82023: 22024: 62025: 92026 (partial year): 7
2007high 11 (2013) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRD

60in 2025

2008: 84 days median2009: 27 days median2010: 150 days median2011: 36 days median2012: 30 days median2013: 33 days median2014: 134 days median2015: 130 days median2016: 164 days median2017: 89 days median2018: 62 days median2019: 178 days median2020: 137 days median2021: 134 days median2022: 175 days median2024: 70 days median2025: 60 days median2026 (partial year): 70 days median
2007high 178 (2019) · low 27 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRD

1in 2024

2010: 12013: 12023: 12024: 12026 (partial year): 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KRD

1,572in 2025

2007: 212008: 142009: 402010: 612011: 1022012: 1372013: 2442014: 1592015: 3372016: 4372017: 7362018: 1,0662019: 1,1852020: 1,1672021: 1,4442022: 1,4982023: 1,3712024: 1,5352025: 1,572
2007high 1,572 (2025) · low 14 (2008)2025

MAUDE reports naming product code KRD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—021
2008584014
2009427040
20103150161
20115360102
20128300137
201311331244
201471340159
2015111300337
201641640437
20174890736
201846201,066
2019617801,185
2020413701,167
2021313401,444
2022817501,498
20232—11,371
202467011,535
202596001,572
20267701—

What is it indicated for?

The Medusa' Vascular Plug is intended for arterial and venous embolizations in the peripheral vasculature. The product is intended for use by physicians trained and experienced in embolization techniques. Standard techniques for placement of vascular access sheaths, angiographic catheters, and guide wires should be employed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123696: Medusa Vascular Plug.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123696

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026