510(k) Report

510(k) · Cleared

Cleared

DLP Retrograde Coronary Sinus Perfusion Cannula with Auto-Inflate Cuff

K123762510(k) TraditionalCleared Mar 27, 2013110-day reviewClass II21 CFR 870.4210

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medtronic, Inc. · DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass

Cleared on Mar 27, 2013 as substantially equivalent to K901074 (Dlp, Inc., 1990) and 1 other predicate after a 110-day review. Its family tree reaches back 2 generations to 1986.

Decided
Mar 27, 2013
Review
110 days
Class
Class II
Product code
DWF
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K860149 (1986). 3 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK860149 Venous Perfusion Cannula W/Cuff Cat. NO. 94015Dlp, Inc. · 1986 · Recalled
  2. 1 generation backK030696 Retrograde Coronary Sinus Perfusion Cannula with NO Pressure Line…Medtronic Perfusion Systems · 2003
  3. This deviceK123762 DLP Retrograde Coronary Sinus Perfusion Cannula with Auto-Inflate CuffMedtronic, Inc. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K860149Venous Perfusion Cannula W/Cuff Cat. NO. 94015Dlp, Inc.19869
−1K030696Retrograde Coronary Sinus Perfusion Cannula with NO Pressure Line (15 French…Medtronic Perfusion Systems2003—
0 (this device)K123762DLP Retrograde Coronary Sinus Perfusion Cannula with Auto-Inflate CuffMedtronic, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
FIG. 1 — Lineage of K123762, 1986–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWF device

  1. #1 K251258 MC2™ Two-Stage Venous Cannula; MC2X™…score 14.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K901074Code #94315 Retrograde Coronary Sinus Perf Cannula
Summary page 1
…scular catheter, cannula, or tubing Regulation Number: 21 CFR 870.42 10 Product Code: DWF Product Cas1 Classification: CasI Predicate Devices K90 1074 Retrograde Coronary Sinus Perfusion Cannula K030696 Retrograde Coronary Sinus Perfusion Cannula…
Dlp, Inc.1990—
*K030696Retrograde Coronary Sinus Perfusion Cannula with NO Pressure Line (15 French, Manual and…
Summary page 1
…70.42 10 Product Code: DWF Product Cas1 Classification: CasI Predicate Devices K90 1074 Retrograde Coronary Sinus Perfusion Cannula K030696 Retrograde Coronary Sinus Perfusion Cannula without Pressure Monitoring Lumen ===…
Medtronic Perfusion Systems2003—

Also cleared against K901074: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 3 companies; a new generation was cleared every 17.0 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K901074.

How does its category compare?

All DWF devices

DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DWF

4in 2025

2007: 22008: 62009: 82010: 32011: 52012: 102013: 92014: 142015: 92016: 32017: 52018: 52019: 32020: 32021: 52022: 22023: 22024: 32025: 42026 (partial year): 8
2007high 14 (2014) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWF

89in 2025

2008: 95 days median2009: 148 days median2010: 62 days median2011: 85 days median2012: 110 days median2013: 110 days median2014: 110 days median2015: 46 days median2016: 32 days median2017: 127 days median2018: 30 days median2019: 120 days median2020: 30 days median2021: 358 days median2024: 29 days median2025: 89 days median2026 (partial year): 81 days median
2007high 358 (2021) · low 29 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DWF

4in 2024

2007: 252008: 252009: 212010: 262011: 132012: 372013: 14, 1 Class I2014: 62015: 3, 1 Class I2016: 32017: 2, 1 Class I2018: 102019: 22021: 32024: 42026 (partial year): 20
2007high 37 (2012) · low 0 (2020)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · DWF

1,020in 2025

2007: 1212008: 1262009: 992010: 1972011: 2122012: 2332013: 2382014: 3252015: 2182016: 1442017: 1012018: 1182019: 1792020: 1422021: 1622022: 2762023: 4702024: 4012025: 1,020
2007high 1,020 (2025) · low 99 (2009)2025

MAUDE reports naming product code DWF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—25121
200869525126
200981482199
201036226197
201158513212
20121011037233
2013911014 (1)238
2014141106325
20159463 (1)218
20163323144
201751272 (1)101
201853010118
201931202179
20203300142
202153583162
20222—0276
20232—0470
20243294401
202548901,020
202688120—

What is it indicated for?

This device is intended for use during cardiopulmonary bypass surgery up to six hours or less, for the delivery of cardioplegia retrogradely through the coronary sinus.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123762: DLP Retrograde Coronary Sinus Perfusion Cannula with Auto-Inflate Cuff.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123762

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026