510(k) · Cleared
ClearedAxsos 3 TI Locking Plate System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Stryker Trauma AG · HRS Plate, Fixation, Bone
Cleared on Mar 28, 2013 as substantially equivalent to K061012 (Howmedica Osteonics Corp., 2006) and 5 other predicates after a 92-day review. Its family tree reaches back 2 generations to 2006. 19 later devices descend from it.
- Decided
- Mar 28, 2013
- Review
- 92 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 6
Its longest line of descent runs back 2 generations to K061012 (2006). 6 ancestors in all, the oldest K972323 (1997). 19 later devices descend from it, 3 citing it directly.
- Root · 2 generations backK061012 Axsos Plus Locking Plate SystemHowmedica Osteonics Corp. · 2006 · Recalled
- 1 generation backK122308 Axsos Distal Lateral Femur TS Long PlatesHowmedica Osteonics Corp., Dba Stryker Orthopaedics · 2012
- This deviceK123964 Axsos 3 TI Locking Plate SystemStryker Trauma AG · 2013
- Descendant · cites it directly · 12 of its ownK133440 Axsos 3 TI Locking Plate System Line ExtensionStryker Trauma AG · 2013
- Descendant · 2 generations on · 11 of its ownK173166 ANTHEM Fracture SystemGlobus Medical, Inc. · 2017
- Descendant · 3 generations on · 10 of its ownK180554 ANTHEM Fracture SystemGlobus Medical, Inc. · 2018
- Descendant · 3 generations on · 8 of its ownK202496 ANTHEM Fracture SystemGlobus Medical, Inc. · 2020
- Descendant · 4 generations on · 7 of its ownK212433 Anthem Fracture SystemGlobus Medical, Inc. · 2021
Showing 5 of 19 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 19 · See all- K133440Axsos 3 TI Locking Plate System Line ExtensionStryker Trauma AG · 2013 · cites it directly12descendants
- K173166ANTHEM Fracture SystemGlobus Medical, Inc. · 2017 · 2 generations on11descendants
- K180554ANTHEM Fracture SystemGlobus Medical, Inc. · 2018 · 3 generations on10descendants
- K202496ANTHEM Fracture SystemGlobus Medical, Inc. · 2020 · 3 generations on8descendants
- K212433Anthem Fracture SystemGlobus Medical, Inc. · 2021 · 4 generations on7descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K061012 | Axsos Plus Locking Plate System | Howmedica Osteonics Corp. | 2006 | 2 |
| −1 | K122308 | Axsos Distal Lateral Femur TS Long Plates | Howmedica Osteonics Corp., Dba Stryker Orthopaedics | 2012 | — |
| 0 (this device) | K123964 | Axsos 3 TI Locking Plate System | Stryker Trauma AG | 2013 | — |
| +1 | K133440 | Axsos 3 TI Locking Plate System Line Extension | Stryker Trauma AG | 2013 | — |
| +2 | K173166 | ANTHEM Fracture System | Globus Medical, Inc. | 2017 | — |
| +3 | K180554 | ANTHEM Fracture System | Globus Medical, Inc. | 2018 | — |
| +3 | K202496 | ANTHEM Fracture System | Globus Medical, Inc. | 2020 | — |
| +4 | K212433 | Anthem Fracture System | Globus Medical, Inc. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 2001 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
| 2024 | 4 | 0 |
| 2025 | 3 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (6)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K061012 | Axsos Plus Locking Plate SystemSummary page 2…rison showed that the proposed device is substantially equivalent in intended, use, materials and performance characteristics to the following predicate devices: * K061012/K122308 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia… | 2006 |
| * | K122308 | Axsos Distal Lateral Femur TS Long PlatesSummary page 2…owed that the proposed device is substantially equivalent in intended, use, materials and performance characteristics to the following predicate devices: * K061012/K122308 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia Plates… | 2012 |
| * | K062564 | Synthes LCP Distal Femur PlatesSummary page 2…equivalent in intended, use, materials and performance characteristics to the following predicate devices: * K061012/K122308 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia Plates * K972323 Osteo BOS System " K012162 S… | 2006 |
| * | K052390 | Synthes LCP Proximal Tibia Plates Line ExtensionSummary page 2…ormance characteristics to the following predicate devices: * K061012/K122308 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia Plates * K972323 Osteo BOS System " K012162 Stryker Plating System Basic Fragment Set Non-C… | 2005 |
| * | K972323 | Osteo Bos SystemSummary page 2…e devices: * K061012/K122308 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia Plates * K972323 Osteo BOS System " K012162 Stryker Plating System Basic Fragment Set Non-Clinical Testing Non-clinical laboratory testing w… | 1997 |
| * | K012162 | Stryker Plating System Basic Fragment SetSummary page 2…08 AxSOS Plus Locking Plate System " K062564 Synthes LCP Distal Femur Plates " K052390 Synthes LCP Proximal Tibia Plates * K972323 Osteo BOS System " K012162 Stryker Plating System Basic Fragment Set Non-Clinical Testing Non-clinical laboratory testing was performed for the AxSOS 3 Ti… | 2001 |
What descends from it? (19)
See all 193 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 6.4 years on median.
- 1 of the 6 ancestors has a recall of any class.
- Of its descendants, K133440 (Stryker Trauma AG, 2013) has gone furthest, with 12 descendants of its own.
- 7 other devices also cite its predicate K061012.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
The AxSOS 3 Ti Locking Plate System is intended for long bone fracture fixation.
Indications include:
Diapyseal, metaphyseal, epiphyseal, extra- and intra-articular fractures
Non-unions and malunions
Normal and osteopenic bone
Osteotomies
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K123964 · printed Nov 6, 2026
Cite this page
510(k) Report. “K123964: Axsos 3 TI Locking Plate System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123964
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026