Improve Blood Collection Set and Improsafe Blood Collection Set

K123987510(k) TraditionalCleared Aug 27, 2013244-day reviewClass II21 CFR 862.1675Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Innovative Medical Technologies, Inc. · JKA Tubes, Vials, Systems, Serum Separators, Blood Collection

Cleared on Aug 27, 2013 after a 244-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it. It has been recalled 3 times.

Decided
Aug 27, 2013
Review
244 days
Class
Class II
Product code
JKA
Recalls
3
Predicates
0

2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2021: 1 descendant cleared2010201520202025
  1. This deviceK123987 Improve Blood Collection Set and Improsafe Blood Collection SetInnovative Medical Technologies, Inc. · 2013
  2. Descendant · cites it directly · 0 of its ownK202188 Safety Blood Collection Sets for Single UseAnhui Hongyu Wuzhou Medical Manufacturer Co., Ltd. · 2021
  3. Descendant · cites it directly · 0 of its ownK163093 Safety Blood Collection SetJiangsu Shenli Medical Production Co., Ltd. · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K202188Safety Blood Collection Sets for Single UseAnhui Hongyu Wuzhou Medical Manufacturer Co., Ltd. · 2021 · cites it directly0descendants
  • K163093Safety Blood Collection SetJiangsu Shenli Medical Production Co., Ltd. · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K123987Improve Blood Collection Set and Improsafe Blood Collection SetInnovative Medical Technologies, Inc.2013—
+1K202188Safety Blood Collection Sets for Single UseAnhui Hongyu Wuzhou Medical Manufacturer Co., Ltd.2021—
+1K163093Safety Blood Collection SetJiangsu Shenli Medical Production Co., Ltd.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202110
FIG. 1 — Lineage of K123987, 2013–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JKA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JKA device

  1. #1 K200027 Blood Collection Needle with/without Holder…score 15.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K202188Safety Blood Collection Sets for Single UseAnhui Hongyu Wuzhou Medical Manufacturer Co., Ltd.20210
K163093Safety Blood Collection SetJiangsu Shenli Medical Production Co., Ltd.20170

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 22, 2017Class IIZ-2549-2018Under Investigation by firmLeaks complaints.
Sep 22, 2017Class IIZ-1217-2019Nonconforming Material/ComponentComplain due to the hub needle came out when the nurse draw the blood and removed the tube.
Oct 19, 2016Class IIZ-2790-2018Nonconforming Material/ComponentComplaints about the needle is not smooth, with discoloration, a kind of gel agglomeration on the needle tip.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K202188 (Anhui Hongyu Wuzhou Medical Manufacturer Co., Ltd., 2021) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JKA devices

JKA Tubes, Vials, Systems, Serum Separators, Blood Collection: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · JKA

7in 2025

2007: 42008: 22009: 22010: 42012: 12013: 32014: 12015: 12016: 42017: 22018: 12019: 62020: 62021: 42022: 92023: 172024: 62025: 72026 (partial year): 8
2007high 17 (2023) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JKA

115in 2025

2007: 281 days median2010: 28 days median2013: 244 days median2016: 116 days median2019: 181 days median2020: 181 days median2021: 217 days median2022: 164 days median2023: 189 days median2024: 240 days median2025: 115 days median2026 (partial year): 250 days median
2007high 281 (2007) · low 28 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JKA

13in 2025

2007: 32008: 32009: 32010: 42011: 142012: 22013: 12014: 12015: 62016: 12017: 22018: 22019: 92021: 32022: 22023: 22025: 132026 (partial year): 1
2007high 14 (2011) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JKA

6,089in 2025

2007: 732008: 782009: 422010: 372011: 672012: 542013: 332014: 682015: 412016: 652017: 2,0392018: 9,7312019: 6,4692020: 3,7742021: 3,6102022: 3,3752023: 4,4002024: 4,6092025: 6,089
2007high 9,731 (2018) · low 33 (2013)2025

MAUDE reports naming product code JKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074281373
20082—378
20092—342
2010428437
20110—1467
20121—254
20133244133
20141—168
20151—641
20164116165
20172—22,039
20181—29,731
2019618196,469
2020618103,774
2021421733,610
2022916423,375
20231718924,400
2024624004,609
20257115136,089
202682501—

What is it indicated for?

Improve Blood Collection Set and Improsafe Blood Collection Set are winged blood collection needles with flexible tubing and a female luer adapter intended for venipuncture to obtain blood samples from patients. Some reorder numbers are provided with a male luer adapter. The male luer adapter contains a non-patient needle end for puncturing the stopper of an evacuated blood collection tube. Those without a male luer adapter are provided with a protective…

Read the full statement (210 words)

Improve Blood Collection Set and Improsafe Blood Collection Set are winged blood collection needles with flexible tubing and a female luer adapter intended for venipuncture to obtain blood samples from patients. Some reorder numbers are provided with a male luer adapter. The male luer adapter contains a non-patient needle end for puncturing the stopper of an evacuated blood collection tube. Those without a male luer adapter are provided with a protective cap on the end of the female luer adapter.

The Improsafe Blood Collection Set is provided with an attached safety shield for covering the used needle prior to disposal. After withdrawal of the needle from the patient’s vein, the attached safety shield can be manually activated to cover the needle immediately after use to minimize risk of accidental needle stick.

The Improve Blood Collection Set and Improsafe Blood Collection Set is also indicated for short-term (up to 2 hours) intravenous administration of fluids and may be used for any patient population with consideration given to patient size, appropriateness for the solution being infused and duration of therapy. For devices that include the male luer adapter: after removing the attached male luer adapter from the blood collection set, connect the female luer adapter to a syringe or other compatible/appropriate device.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K123987: Improve Blood Collection Set and Improsafe Blood Collection Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K123987

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026