510(k) Report

510(k) · Cleared

Cleared

Radial-Cuf Non-Invasive Blood Pressure Cuff

K123996510(k) TraditionalCleared Apr 9, 2013104-day reviewClass II21 CFR 870.1120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Medical Systems Information Technologies, Inc. · DXQ Blood Pressure Cuff

Cleared on Apr 9, 2013 as substantially equivalent to K120125 (Ge Medical Systems Information Technologies, Inc., 2012) after a 104-day review. Its family tree reaches back 3 generations to 1979.

Decided
Apr 9, 2013
Review
104 days
Class
Class II
Product code
DXQ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K790810 (1979). 8 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2002: 1 other ancestor1994: 1 other ancestor1992: 1 other ancestor1991: 1 other ancestor1989: 1 other ancestorK790810 · Disposa-Cuf · Crest Medical Equipment · 1979K974080 · Critikon Soft Blood Pressure Cuff · Johnson & Johnson Medical, Inc. · 1998 · recalledK120125 · Soft-Cuf, Classic-Cuf, Dura-Cuf, Sensa-Cuf · Ge Medical Systems Information Technologies, Inc. · 20121980199020002010
  1. Root · 3 generations backK790810 Disposa-CufCrest Medical Equipment · 1979
  2. 2 generations backK974080 Critikon Soft Blood Pressure CuffJohnson & Johnson Medical, Inc. · 1998 · Recalled
  3. 1 generation backK120125 Soft-Cuf, Classic-Cuf, Dura-Cuf, Sensa-CufGe Medical Systems Information Technologies, Inc. · 2012
  4. This deviceK123996 Radial-Cuf Non-Invasive Blood Pressure CuffGe Medical Systems Information Technologies, Inc. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K790810Disposa-CufCrest Medical Equipment1979—
−2K974080Critikon Soft Blood Pressure CuffJohnson & Johnson Medical, Inc.19981
−1K120125Soft-Cuf, Classic-Cuf, Dura-Cuf, Sensa-CufGe Medical Systems Information Technologies, Inc.2012—
0 (this device)K123996Radial-Cuf Non-Invasive Blood Pressure CuffGe Medical Systems Information Technologies, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199110
199210
199410
200210
FIG. 1 — Lineage of K123996, 1979–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXQ device

  1. #1 K254287 Medline Reusable Blood Pressure Cuffscore 13.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K120125Soft-Cuf, Classic-Cuf, Dura-Cuf, Sensa-Cuf
Summary page 1
…ure Cuff Commnon/Usual Name: Blood Pressure Cuff Classification Names: Blood Pressure Cuff Product Code: DXQ Predicate Device(s): K120125 Non-Invasive Blood Pressure Cuffs Device Description: The RADIAL-CUF is a Non-Invasive Blood Pressure cuff that…
Ge Medical Systems Information Technologies, Inc.2012—

Also cleared against K120125: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 3 companies; a new generation was cleared every 14.4 years on median.
  • 2 of the 8 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K120125.

How does its category compare?

All DXQ devices

DXQ Blood Pressure Cuff: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DXQ

3in 2025

2007: 22008: 72009: 52010: 22011: 52012: 42013: 22014: 42015: 102016: 42017: 22018: 52019: 32020: 32021: 42022: 42023: 52024: 22025: 32026 (partial year): 4
2007high 10 (2015) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXQ

174in 2025

2008: 118 days median2009: 57 days median2011: 121 days median2012: 102 days median2014: 105 days median2015: 59 days median2016: 217 days median2018: 225 days median2019: 44 days median2020: 207 days median2021: 105 days median2022: 105 days median2023: 79 days median2025: 174 days median2026 (partial year): 102 days median
2007high 225 (2018) · low 44 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXQ

1in 2025

2011: 12025: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXQ

20in 2025

2007: 32008: 42009: 22010: 12011: 52012: 72013: 92014: 92015: 232016: 502017: 672018: 442019: 412020: 52021: 122022: 32023: 202024: 152025: 20
2007high 67 (2017) · low 1 (2010)2025

MAUDE reports naming product code DXQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—03
2008711804
200955702
20102—01
2011512115
2012410207
20132—09
2014410509
20151059023
20164217050
20172—067
20185225044
2019344041
2020320705
20214105012
2022410503
2023579020
20242—015
20253174120
202641020—

What is it indicated for?

GE CRITIKON blood pressure cuffs are accessories used in conjunction with noninvasive blood pressure (NIBP) measurement systems. The RADIAL-CUF is intended for use with automated oscillometric NIBP devices to measure radial arterial pressure on the forearm. The RADIAL-CUF is available in adult size only. The device is non-sterile and is semi-disposable (may be single-patient use or optional limited reuse). The cuff is intended for use in patients whose…

Read the full statement (134 words)

GE CRITIKON blood pressure cuffs are accessories used in conjunction with noninvasive blood pressure (NIBP) measurement systems. The RADIAL-CUF is intended for use with automated oscillometric NIBP devices to measure radial arterial pressure on the forearm. The RADIAL-CUF is available in adult size only. The device is non-sterile and is semi-disposable (may be single-patient use or optional limited reuse). The cuff is intended for use in patients whose upper arm circumference is greater than 40cm or in patients where currently marketed GE CRITIKON upper arm cuffs cannot be used, due to excess width of the cuff or conical shape of the upper arm. The forearm cuff is intended to be placed on the patient's forearm with circumference ranging from 26cm -36cm. The devices are not designed, sold or intended for use except as indicated.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K123996: Radial-Cuf Non-Invasive Blood Pressure Cuff.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K123996

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026