510(k) · Cleared
ClearedLifespan Eptfe Vascular Graft
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
LeMaitre Vascular, Inc. · DSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter
Cleared on Feb 5, 2013 as substantially equivalent to K933590 (Baxter Healthcare Corp, 1994) and 3 other predicates after a 35-day review. Its family tree reaches back 2 generations to 1994.
- Decided
- Feb 5, 2013
- Review
- 35 days
- Class
- Class II
- Product code
- DSY
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 2 generations to K933590 (1994). 4 ancestors in all. No later device cites it as a predicate yet.
- Root · 2 generations backK933590 Baxter Reinforced Expanded Ptfe Vascular GraftBaxter Healthcare Corp · 1994
- 1 generation backK032900 Lifespan Reinforced Eptfe Straight Vascular Grafts, Externally…Edwards Lifesciences, LLC · 2003
- This deviceK130016 Lifespan Eptfe Vascular GraftLeMaitre Vascular, Inc. · 2013
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K933590 | Baxter Reinforced Expanded Ptfe Vascular Graft | Baxter Healthcare Corp | 1994 | — |
| −1 | K032900 | Lifespan Reinforced Eptfe Straight Vascular Grafts, Externally Supported… | Edwards Lifesciences, LLC | 2003 | — |
| 0 (this device) | K130016 | Lifespan Eptfe Vascular Graft | LeMaitre Vascular, Inc. | 2013 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DSY device
- #1 K252445 Fusion Bioline Vascular Graftscore 12.4 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K933590 | Baxter Reinforced Expanded Ptfe Vascular GraftSummary page 1…scular graft prosthesis Classification Name: Prosthesis, Vascular Graft Predicate Devices: Baxter reinforced expanded PTFE vascular graft (K933590); Baxter reinforced expanded PTFE stepped vascular graft (K944844); Baxter ePTFE externally… | 1994 |
| * | K944844 | Baxter Reinforced Expanded Ptfe Stepped Vascular GraftSummary page 1…ices: Baxter reinforced expanded PTFE vascular graft (K933590); Baxter reinforced expanded PTFE stepped vascular graft (K944844); Baxter ePTFE externally supported vascular grafts (K944858); LifeSpan reinforced… | 1995 |
| * | K944858 | Baxter Eptfe Externally Supported Vascular GraftsSummary page 1…3590); Baxter reinforced expanded PTFE stepped vascular graft (K944844); Baxter ePTFE externally supported vascular grafts (K944858); LifeSpan reinforced ePTFE straight, externally supported, stepped vascular grafts… | 1995 |
| * | K032900 | Lifespan Reinforced Eptfe Straight Vascular Grafts, Externally Supported Vascular…Summary page 1…supported vascular grafts (K944858); LifeSpan reinforced ePTFE straight, externally supported, stepped vascular grafts (K032900) Device Description: LifeSpan Vascular Grafts are consisting of a base tube of expanded PTFE that is w… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 9.9 years on median.
- None of the 4 ancestors has a recall.
- 3 other devices also cite its predicate K933590.
How does its category compare?
All DSY devicesDSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · DSY
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DSY
160in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DSY
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DSY
151in 2025
MAUDE reports naming product code DSY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 120 |
| 2008 | 1 | — | 0 | 164 |
| 2009 | 5 | 73 | 2 | 193 |
| 2010 | 4 | 55 | 5 | 187 |
| 2011 | 1 | — | 0 | 165 |
| 2012 | 4 | 30 | 0 | 177 |
| 2013 | 5 | 69 | 1 | 207 |
| 2014 | 2 | — | 0 | 352 |
| 2015 | 1 | — | 0 | 460 |
| 2016 | 1 | — | 2 | 217 |
| 2017 | 3 | 269 | 0 | 193 |
| 2018 | 1 | — | 0 | 200 |
| 2019 | 1 | — | 0 | 232 |
| 2020 | 1 | — | 0 | 169 |
| 2021 | 2 | — | 0 | 168 |
| 2022 | 2 | — | 0 | 155 |
| 2023 | 2 | — | 0 | 149 |
| 2024 | 5 | 160 | 0 | 153 |
| 2025 | 2 | — | 1 | 151 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
The LeMaitre LifeSpan ePTFE vascular grafts are indicated for use as a vascular prosthesis only. The grafts are intended for bypass or reconstruction of diseased or occluded blood vessels, or for arteriovenous shunts for blood access.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K130016 · printed Nov 6, 2026
Cite this page
510(k) Report. “K130016: Lifespan Eptfe Vascular Graft.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130016
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026