510(k) Report

510(k) · Cleared

Cleared

Pictzar Digital Planimetry Software Application 7.0

K130165510(k) TraditionalCleared Aug 30, 2013219-day reviewClass I21 CFR 878.4160

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Advanced Planimetric Services, LLC · FXN Tape, Camera, Surgical

Cleared on Aug 30, 2013 after a 219-day review. The FDA summary names its predicate without a number.

Decided
Aug 30, 2013
Review
219 days
Class
Class I
Product code
FXN
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K130165Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Verg Videometer
Named without a submission number
—
*—Visitrak
Named without a submission number
—
*—Silhouette
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All FXN devices

FXN Tape, Camera, Surgical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · FXN

2in 2013

2007: 12013: 2
2007high 2 (2013) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FXN

Too few FXN 510(k)s in any year since 2007 to give a median.

Recalls per year · FXN

No recall names FXN since 2007.

Adverse event reports per year · FXN

No MAUDE report names FXN since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20110—00
20120—00
20132—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

PictZar planimetry software is indicated for wound measurement and documentation and can be used on all external wound types.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130165: Pictzar Digital Planimetry Software Application 7.0.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K130165

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026