510(k) Report

510(k) · Cleared

Recalled · Class II · 2017

TQ-Prep Workstation, Prepplus 2 Workstation

K130253510(k) TraditionalCleared Jul 15, 2013164-day reviewClass I21 CFR 862.2750Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Beckman Coulter, Inc. · PER Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cytometric Analysis

Cleared on Jul 15, 2013 as substantially equivalent to K874188 (Coulter Electronics, Inc., 1988) after a 164-day review. Its family tree reaches back 1 generation to 1988. It has been recalled 2 times.

Decided
Jul 15, 2013
Review
164 days
Class
Class I
Product code
PER
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K874188 (1988). No later device cites it as a predicate yet.

K874188 · Coulter Immunoprep Leukocyte/Q-Prep Immuno WRK Sta · Coulter Electronics, Inc. · 19881985199019952000200520102015
  1. Root · 1 generation backK874188 Coulter Immunoprep Leukocyte/Q-Prep Immuno WRK StaCoulter Electronics, Inc. · 1988
  2. This deviceK130253 TQ-Prep Workstation, Prepplus 2 WorkstationBeckman Coulter, Inc. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K874188Coulter Immunoprep Leukocyte/Q-Prep Immuno WRK StaCoulter Electronics, Inc.1988—
0 (this device)K130253TQ-Prep Workstation, Prepplus 2 WorkstationBeckman Coulter, Inc.2013—
FIG. 1 — Lineage of K130253, 1988–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PER? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K874188Coulter Immunoprep Leukocyte/Q-Prep Immuno WRK Sta
Summary page 1
…Candidate B Predicate Manufacturer 510(k) Number TQ-Prep Q-Prep Beckman Coulter, Inc. K874 188 PrepPlus 2 Manual Pipette Various Not applicable Beckman Coulter, Inc.…
Coulter Electronics, Inc.1988—
*—Manual Pipette
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 22, 2017Class IIZ-2690-2017Software designWhen samples are prepared using the PrepPlus or PrepPlus 2 sample preparation systems and then run on a Flow cytometer, there is an imprecision in the absolute counts on only the first tube in a run.
May 22, 2017Class IIZ-2689-2017Software designWhen samples are prepared using the PrepPlus or PrepPlus 2 sample preparation systems and then run on a Flow cytometer, there is an imprecision in the absolute counts on only the first tube in a run.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All PER devices

PER Automated Pipetting, Diluting And Specimen Processing Workstations For Flow Cytometric Analysis: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · PER

2in 2013

2013: 2
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PER

Too few PER 510(k)s in any year since 2007 to give a median.

Recalls per year · PER

1in 2025

2024: 12025: 1
2007high 1 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PER

6in 2025

2013: 12014: 22015: 12016: 22020: 372021: 542022: 632023: 112024: 32025: 6
2007high 63 (2022) · low 0 (2007)2025

MAUDE reports naming product code PER, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20132—01
20140—02
20150—01
20160—02
20170—00
20180—00
20190—00
20200—037
20210—054
20220—063
20230—011
20240—13
20250—16
20260—0—

What is it indicated for?

The COULTER TQ-Prep Workstation is intended to prepare leukocytes from whole blood for In Vitro Diagnostic (IVD) Use when used with the COULTER ImmunoPrep Reagent Systemi and cleared Beckman Coulter IVD applications on cleared Beckman Coulter flow cytometers. Pipetting of ImmunoPrep Reagent System (lyse, stabilizer, and fixative reagents) to samples prepared either manually or with the COULTER PrepPlus 2 sample preparation device to achieve lysis of…

Read the full statement (172 words)

The COULTER TQ-Prep Workstation is intended to prepare leukocytes from whole blood for In Vitro Diagnostic (IVD) Use when used with the COULTER ImmunoPrep Reagent Systemi and cleared Beckman Coulter IVD applications on cleared Beckman Coulter flow cytometers.

Pipetting of ImmunoPrep Reagent System (lyse, stabilizer, and fixative reagents) to samples prepared either manually or with the COULTER PrepPlus 2 sample preparation device to achieve lysis of whole blood samples. Use of COULTER TQ-Prep with cleared Beckman Coulter flow cytometers is described In each application's Instructions for Use. For In Vitro Diagnosic Use Only

The COULTER PrepPlus 2, when used in combinations with the COULTER TO-Prep Workstation, is intended to prepare human whole blood for In Vitro Diagnostic (IVD) Use with cleared Beckman Coulter IVO applications on cleared Beckman Coulter flow cytometers.

Pipetting blood, cleared Beckman Coulter IVO reagents and Flow-Count Fluorospheres to prepare samples for flow cytometric analysis. Use of the PrepPlus 2 with cleared Beckman Coulter flow cytometers is described in each application Instructions for Use. For InVitro Diagnostic Use Only

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K130253: TQ-Prep Workstation, Prepplus 2 Workstation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130253

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026