510(k) Report

510(k) · Cleared

Cleared

Cardioday

K130516510(k) TraditionalCleared Aug 23, 2013177-day reviewClass II21 CFR 870.1425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Getemed Medizin- Und Informationstechnik AG · DQK Computer, Diagnostic, Programmable

Cleared on Aug 23, 2013 as substantially equivalent to K070280 (Getemed Medizin- Und Informationstechnik AG, 2007) after a 177-day review. Its family tree reaches back 3 generations to 1995. 2 later devices descend from it.

Decided
Aug 23, 2013
Review
177 days
Class
Class II
Product code
DQK
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K930564 (1995). 2 later devices descend from it, 1 citing it directly.

  1. Root · 3 generations backK930564 Holter for WindowsNorth East Monitoring, Inc. · 1995
  2. 2 generations backK051471 CardiodayGetemed Medizin- Und Informationstechnik AG · 2005
  3. 1 generation backK070280 Cardioday, Version 2.0Getemed Medizin- Und Informationstechnik AG · 2007
  4. This deviceK130516 CardiodayGetemed Medizin- Und Informationstechnik AG · 2013
  5. Descendant · cites it directly · 1 of its ownK162023 CardioDay V2.5Getemed Medizin- Und Informationstechnik AG · 2017
  6. Descendant · 2 generations on · 0 of its ownK242583 AT-Patch (ATP-C130/ATP-C70)Atsens Co., Ltd. · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K162023CardioDay V2.5Getemed Medizin- Und Informationstechnik AG · 2017 · cites it directly1descendant
  • K242583AT-Patch (ATP-C130/ATP-C70)Atsens Co., Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K930564Holter for WindowsNorth East Monitoring, Inc.1995—
−2K051471CardiodayGetemed Medizin- Und Informationstechnik AG2005—
−1K070280Cardioday, Version 2.0Getemed Medizin- Und Informationstechnik AG2007—
0 (this device)K130516CardiodayGetemed Medizin- Und Informationstechnik AG2013—
+1K162023CardioDay V2.5Getemed Medizin- Und Informationstechnik AG2017—
+2K242583AT-Patch (ATP-C130/ATP-C70)Atsens Co., Ltd.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202510
FIG. 1 — Lineage of K130516, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQK device

  1. #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.6 · 28 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070280Cardioday, Version 2.0
Summary page 1
…formation: Device Manufacturer 510(k) Number CardioDay ' 2.0 GETEMED Medizin- und K070280 Informationstechnilk AG 6. Device Description: CardioDay@ is a software…
Getemed Medizin- Und Informationstechnik AG2007—
†K032513T-Wave Alternans (Twa) Algorithm OptionGe Medical Systems Information Technologies2003—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K162023CardioDay V2.5Getemed Medizin- Und Informationstechnik AG20171

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 6.5 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K162023 (Getemed Medizin- Und Informationstechnik AG, 2017) has gone furthest, with 1 descendant of its own.

How does its category compare?

All DQK devices

DQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DQK

23so far in 2026, the most since 2007

2007: 132008: 42009: 122010: 92011: 122012: 72013: 132014: 92015: 72016: 152017: 72018: 142019: 152020: 162021: 162022: 192023: 212024: 132025: 222026 (partial year): 23
2007high 23 (2026) · low 4 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQK

95in 2025

2007: 83 days median2008: 70 days median2009: 93 days median2010: 64 days median2011: 69 days median2012: 74 days median2013: 68 days median2014: 90 days median2015: 125 days median2016: 190 days median2017: 146 days median2018: 150 days median2019: 113 days median2020: 123 days median2021: 132 days median2022: 136 days median2023: 133 days median2024: 100 days median2025: 95 days median2026 (partial year): 151 days median
2007high 190 (2016) · low 64 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQK

1in 2025

2007: 42008: 12009: 22010: 32011: 22012: 32013: 12014: 42015: 22017: 22018: 62019: 12020: 12021: 12022: 22023: 22024: 242025: 12026 (partial year): 2
2007high 24 (2024) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQK

433in 2025

2007: 182008: 342009: 402010: 492011: 552012: 1292013: 1802014: 1152015: 1312016: 3402017: 2522018: 2612019: 2182020: 2152021: 3512022: 3192023: 3402024: 5572025: 433
2007high 557 (2024) · low 18 (2007)2025

MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071383418
2008470134
20091293240
2010964349
20111269255
20127743129
201313681180
20149904115
201571252131
2016151900340
201771462252
2018141506261
2019151131218
2020161231215
2021161321351
2022191362319
2023211332340
20241310024557
202522951433
2026231512—

What is it indicated for?

CardioDay® is a Holter software which is indicated for patients who may benefit from a long-term continuous electrocardiographic (ECG) recording, including, but not limited to, those with complaints of palpitations, syncope, chest pain, shortness of breath, or those that need to be monitored to judge their current cardiac functionality such as patients who have recently received pacemakers.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130516: Cardioday.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130516

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026