510(k) Report

510(k) · Cleared

Cleared

Omnipod Insulin Management System

K131294510(k) TraditionalCleared Aug 29, 2013115-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Insulet Corporation · LZG Pump, Infusion, Insulin

Cleared on Aug 29, 2013 as substantially equivalent to K122953 (Insulet Corporation, 2012) after a 115-day review. Its family tree reaches back 3 generations to 2005. 1 of the 4 devices in its family, counting itself, has a Class I recall.

Decided
Aug 29, 2013
Review
115 days
Class
Class II
Product code
LZG
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K042792 (2005). No later device cites it as a predicate yet. 1 of the 4 devices in this family, counting this one, has a Class I recall.

  1. Root · 3 generations backK042792 Ixl-II Diabetes Management SystemInsulet Corporation · 2005
  2. 2 generations backK111669 Freestyle Glucose Meter Incorporated Into the Omnipod Insulin…Insulet Corporation · 2011
  3. 1 generation backK122953 Omnipod Insulin Managment SystemInsulet Corporation · 2012 · Recalled (Class I)
  4. This deviceK131294 Omnipod Insulin Management SystemInsulet Corporation · 2013

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K042792Ixl-II Diabetes Management SystemInsulet Corporation2005—
−2K111669Freestyle Glucose Meter Incorporated Into the Omnipod Insulin Management SystemsInsulet Corporation2011—
−1K122953Omnipod Insulin Managment SystemInsulet Corporation2012Class I
0 (this device)K131294Omnipod Insulin Management SystemInsulet Corporation2013—
FIG. 1 — Lineage of K131294, 2005–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZG device

  1. #1 K253534 Pivot Insulin Delivery Systemscore 16.8 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122953Omnipod Insulin Managment System
Summary page 1
…on: Class 11, LZG Pump, Infusion, Insulin 880.5725 Predicate Device: OmniPod Insulin Management System K122953, Cleared December 7t1h 2012 Device The OmniPod Insulin Management System is a tubeless Description: insulin…
Insulet Corporation2012Class I

Also cleared against K122953: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K122953Omnipod Insulin Managment SystemInsulet Corporation · 2012 · Direct predicate · ◆ on the line of descent in FIG. 14 Class I recalls

What does this lineage say?

  • The line of descent spans 8 years and passes through 1 company; a new generation was cleared every 12 months on median.
  • 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
  • 3 other devices also cite its predicate K122953.

How does its category compare?

All LZG devices

LZG Pump, Infusion, Insulin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · LZG

2in 2024

2007: 32008: 62009: 22010: 22011: 42012: 32013: 22014: 42015: 12016: 42017: 12018: 12019: 22021: 12022: 12023: 12024: 22026 (partial year): 2
2007high 6 (2008) · low 0 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZG

116in 2016

2007: 112 days median2008: 129 days median2011: 189 days median2012: 73 days median2014: 123 days median2016: 116 days median
2007high 189 (2011) · low 73 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZG

1in 2022

2007: 12008: 132009: 22010: 42011: 22012: 42013: 3, 1 Class I2014: 2, 1 Class I2015: 2, 2 Class I2018: 3, 2 Class I2019: 52022: 1, 1 Class I2026 (partial year): 2, 2 Class I
2007high 13 (2008) · low 0 (2016)2026

Class I (9 since 2007) Class II/III not classified

Adverse event reports per year · LZG

12,004in 2025

2007: 5,1102008: 5,7112009: 9,4712010: 10,1752011: 12,8582012: 18,3672013: 30,0592014: 49,1882015: 69,1362016: 56,5812017: 44,4722018: 32,6522019: 29,0272020: 32,5882021: 31,5222022: 28,2252023: 21,9722024: 18,2282025: 12,004
2007high 69,136 (2015) · low 5,110 (2007)2025

MAUDE reports naming product code LZG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007311215,110
20086129135,711
20092—29,471
20102—410,175
20114189212,858
2012373418,367
20132—3 (1)30,059
201441232 (1)49,188
20151—2 (2)69,136
20164116056,581
20171—044,472
20181—3 (2)32,652
20192—529,027
20200—032,588
20211—031,522
20221—1 (1)28,225
20231—021,972
20242—018,228
20250—012,004
20262—2 (2)—

What is it indicated for?

The OmnniPod® Insulin Management System is intended for subcutaneous (below the skin) delivery of insulin at set and variable rates for the management of diabetes mellitus in persons requiring insulin.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131294: Omnipod Insulin Management System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131294

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026